Star Lawn Pump User Manual

LAWN PUMP QUICK REFERENCE GUIDE
SEE INSTRUCTION MANUAL FOR COMPLETE DETAILS
WHAT CONTROLS WILL YOU USE WITH
2
THIS PUMP?
NOTE: This pump can be used with a variety of
controls. See control manufacturer’s instructions for details.
4
HERE’S HOW TO CHANGE THIS PUMP FROM 230V TO 115V
L1
A B
L2
230V
The motor of this pump is dual voltage and can run on either 115V or 230V. This pump is pre-set in the factory to run at 230V.
5
the cavity with water) before they are first operated. This may take several gallons of water, as the inlet line will be filled in addition to the pump cavity. The longer the inlet line, the more water is required to prime.
1. Disconnect the
HOW TO PRIME YOUR PUMP
CAUTION: All pumps must be primed (filling
outlet union and separate the pipe.
Priming plug with pressure gauge
Air relief plug
Inlet
Outlet
For installation videos, scan with your smart phone.
TYPICAL INSTALLATION
1
NOTE: This pump is equipped with a 2 in. inlet for
maximum water spray.
• 2 in. inlet (suction) opening can be reduced with some loss in performance. If reducing below 1-1/2 in., call factory.
• 1-1/2 in. outlet (discharge) pipe can be reduced with some loss in performance. If reducing below 1-1/4 in., call factory.
60 ft. max.
Inlet pipe to water
Vertical Lift
25 ft.
max
Pipe Support
Water Level
Foot Valve
Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday.
Discharge to Sprinkler System
Outlet Pipe
Inlet Pipe
Motor Cover
Pump Start Relay Pressure Switch with
Tank
Indexing Valve
3
CHECK YOUR BREAKER BOX
This pump is wired for 230V
230V
Need 115V?
see sectioN 4
115V
WARNING: Always disconnect pump from electricity before performing any work on the motor.
For 115V service, remove the motor cover and change the following wires on the terminal board:
a. Using a pair of needle nose pliers, pull the gray
wire with the female flag connector from the “B” terminal spade post. Place it to the left on the “A” terminal space post.
L1
A B
L2
115V
1. b. Pull the red wire with the female flag connector from the “B” terminal. Place it to the right on the L2 terminal space post.
NOTE: Pump may show water stains as a result of factory water testing.
2. Remove priming plug with pressure gauge and the air relief plug on top of pump.
3. Slowly fill pump cavity until water comes out of the air relief hole.
4. Replace air relief plug and continue adding water to pump cavity until water comes out the open outlet pipe at the open union.
5. Wait 10 minutes to see if water level drops below the pipe tee. If level drops, check foot valve. If level stays constant, re-install the priming plug.
6. Reconnect union on outlet
pipe. Open the ball valve (turn handle to line up with pipe), and then turn on breaker to start pump.
Pipe Tee