Star GR138TB2 Operators Manual

Star Manufacturing International Inc.
10 Sunnen Dr. St. Louis, MO 63143
Phone: (314) 781-2777 FAX: (314) 781-3636
2M-Z2153 Rev. A 8/24/99
SPLIT LID TABLE
TOP CLAM
SHELL TOASTER
Installation and
Operating
Instructions
MODEL
GR138TB2 120V
GENERAL INSTALLATION DATA
CAUTION
OPERATING INSTRUCTIONS
Make sure unit is plugged into 20AMP receptacle and is on a dedicated 120V A.C. line.
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
INSTALLATION
1. Plug unit into dedicated 120V A.C. line with 20AMP receptacle. 2, DO NOT plug into 220V line. Doing so will ruin the unit and void the warranty.
3. Each machine has been properly wired and inspected at the factory for operation on the voltage and type of current specified on the nameplate.
CAUTION
DO NOT CONNECT TO ANY OTHER TYPE OF CURRENT OR THE MACHINE WILL BE SERIOUSLY DAMAGED.
4. Level the unit using the adjustable feet in front of the unit (approximately 1/2" adjustment).
5. Place grease catcher cup under spout.
6. DO NOT operate without top burn guard in place.
1. Turn unit on by placing switch in "ON" position. The "Heat On" light, program number and display will flash indicating unit is heating. When the preset temperature isreached, the heating light, display and program light indicator will stop flashing followed by 3 beeps. (Initial startup heating time is approximately 30 minutes)
2. Place product on the bottom cooking surface of the unit and close the lids.
3. Press program button and let displayed time count down to "0" at which time unit will beep. To turn off the beeper, press program button again.
4. Raise lids until it engages into first detent and remove food. Using spatula, scrape residue into grease catcher cup. Note: Metal utensils may be used, however, using nonmetal utensils will prolong the life of the cooking surface.
5. Turn the unit off when not in use.
DO NOT ADJUST TIME AND TEMPERATURE
The unit time and temperature is preset by the factory to the specific customer requirements for flatbread and quesadillas. If adjustments are required for additional food products, please refer to the time or temperature programming section in this manual.
INITIAL STARTUP
Before using the unit for the first time, clean and heat for approximately 30
minutes.
TEMPERATURE/TIMER CONTROLLER OPERATION SPECIFICATIONS
Startup:
1. The preset time will flash until preset temperature is reached.
2. When the control reaches preset
temperature, time display, heat on indicator and program indicator will stop flashing and the alarm will beep three
1
times.
Temperature:
1. To view the actual temperature, press and hold "Temp Button". Display will read "Lo F" if temperature is below 273°F and "Hi F" if temperature is above 573°F.
To Program Time and Temperature:
1. Press and hold "Temp" (actual temperaturedisplays).
2. While holding "TEMP", press and hold any program button on the Left PC board for 1 second, the LED above program lights and display reads "_ _ _ _". Enter the four - digit security code sequence, 4, 3, 2, 1. Starting with the first digit, the center horizontal bar will light on each digit as the security code is entered. The security code will not show on display. Once the correct sequence has been entered, the preset time will be displayed and the LED for that program will begin to flash.
3. Set the time with the "+ or -" buttons.
4. Press the "TEMP" button to save the
time.
5. The preset temperature will now be displayed.
6. Set the desired temperature for this program using the "+ or -" buttons.
7. Press the "TEMP" button to save
temperature and to exit programming mode for this program.
The LED will stop to flash
but will remain lit.
8. Press any other program button within 15 seconds to continue programming without re-entering the security code.
3. While programming a program (LED is flashing), if no input is received for 15 seconds, the unit will revert to normal operation and the security code must be re-entered.
Note: Temperature settings are done with the Left PC board only. The time settings programmed on the Left PC board will also be programmed onto the
Right PC board. See below to make
changes to the Right PC board only.
Each programming change must be saved by pressing the "TEMP" button!
Right PC board (Timer only):
1. To Change the time on Right PC board, press and hold the "TEMP" button on the Left PCboard and press and hold any program button on the Right PC board for one second. The LED above the program button will light and the Right Display will read "_ _ _ _". Enter the four-digit security code sequence, 4, 3, 2, 1. Starting with the first digit, the center horizontal bar will light on each digit as the security code is entered. The security code will not show on display. Once the correct sequence has been entered, the preset time will be displayed and the LED for that program will begin to flash.
2. Set the time with the "+ or -" buttons.
3. Press the "TEMP" button to save the
time.
4. The LED will stop to flash but will remain lit.
5. Press any other program button within 15 seconds to continue programming withoutre-entering the security code.
6. While programming a program (LED is flashing), if no input is received for 15 seconds, the unit will revert to normal operation and the security code must be re-entered.
Operation:
1. Pressing any program button (1-4) will start the timer countdown and display the preset time remaining. The LED for the appropriate program will be lit during countdown and remain lit until another program is selected.
2. When the display reaches "00:00", the buzzer will sound and the digits will flash.
3. Press the program button to silence the buzzer and return the readout to programmed time.
4. The Right and Left boards will operate independent of each other. Both timers can be in operation at the same time. The "00:00" display will show which side is timed out.
2