Star FS1R, FS1D, FS1DT, FS1RT, FS2R Installation And Operation Instructions Manual

...
Page 1
FAST
STEAMER
MODEL
FS1R, FS1D, FS1RT, FS1DT FS2R, FS2D, FS2RT, FS2DT
FSFR, FSFD, FSFRT, FSFDT
Installation and
Instructions
2M-Z10887 Rev. E 7/27/2009
FS2DT
FSFRT
1
Page 2
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 807-9054 Local (314) 781-2777 Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com Warranty@star-mfg.com
Website: www.star-mfg.com
The Star Service Help Desk
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com Telephone: (800) 807-9054 Local (314) 781-2777
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
Page 3
SPECIFICATIONS
A
C
B
A
C
B
FRONT LOADING TOP LOADING
IL1361
FAST STEAMERS SPECIFICATIONS
FRONT LOADING
Model "A" Width "B" Height "C" Depth Approx. Capacity (inches) Direct (D) No. Inches/CM Inches/CM Inches/CM Shp Weight W_x_D_x_H Reservoir (R)
FSFR 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" R FSFD 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" D FSFRT 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" R FSFDT 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" D
TOP LOADING Pan Size
FS1R 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 R FS1D 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 D FS1RT 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 R FS1DT 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 D FS2R 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 R FS2D 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 D FS2RT 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 R FS2DT 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 D
ELECTRICAL SPECIFICATIONS
FrontLoading  Certication
Model No. Voltage Wattage Amps Nema Plug UL CUL
FSF 208V 3,300 15.9 6-20P X X FSF 240V 3,600 15.0 6-20P X X
Top Loading
Model No. Voltage Wattage Amps Nema Plug
FS1/FS2 120V 1,800 15.0 5-15P X ­ FS1/FS2 120VC 1,800 15.0 5-20P X X
3
Page 4
GENERAL INFORMATION
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms.
These models are equipped for the voltage and wattage indicated on the nameplate. These units are designed to operate on alternating current (A.C.), two wire single phase service only and are equipped with an approved lead in cord set with a three prong grounding type plug.
or loss - if damage or loss is not apparent until after equipment is unpacked, a
DO NOT CONNECT TO DIRECT CURRENT (D.C.).
UNPACKING
Carefully remove the steamer from the shipping and packing & protective material. Remove all removable parts and clean with hot water and mild detergent. Wipe the unit using damp cloth. Never hose down the unit with water, this steamer has
Unit should also contain:
• Operations manual & Authorized Service Agent Listing Packet
• Inlet Hose Assembly (non-reservoir units only)
• Spatula tray (front loading units only)
Purchasers Responsibility
• To see that the electric & water services for the unit are installed on site in accordance with
the manufacturer's specications and municipal codes.
A water pressure regulator must be used, failure to operate this unit without a regulator will result in situations that will damage the unit.
4
Page 5
INSTALLATION
ELECTRICAL CONNECTION
For your protection, we recommend that a qualified electrician install this appliance. The electrician should be familiar with electrical installations and your local electrical requirements.
Proper connections and power supply are essential for efcient performance. The supply circuit should
be properly fused as required by local electrical code.
WARNING
Before making any electrical connection be sure to read data plate which is located on the rear of the unit.
Electrical Grounding Instructions
This unit is equipped with a 3-prong (grounded) plug for your protection against shock hazard and must be plugged directly into a properly grounded 3-prong receptacle.
CAUTION
DO NOT CUT OR REMOVE THIS PLUG OR GROUNDED PRONG FROM THE PLUG. CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE DATA
PLATE OF THE UNIT.
PRESET TIME
If adjustments are required, please refer to the time programming section in this manual.
°F/°C CONVERSION
To change the temperature display from °F to °C or from °C to °F, hold the TEMP button while the unit is turned off. While holding the TEMP button, turn the unit on. The display will be the changed temperature mode. To change back, repeat the procedure.
5
Page 6
INSTALLATION continued
Filter
Regulator
To Steamer
Guage
Water
Source
26 psi
IL1532
Lid
Strainer
Water Inlet
IL1537
WATER CONNECTION
These units come equipped with either a direct connect, rear mounted quick disconnect uid control
valve, or a 12 cup water tank with tank drain and supply pump. It is vital that all water supply lines be
thoroughly ushed with clean water before being connected to the steamer.
The Star Fast-Steamer has a water injection system, to ensure your new equipment works at its premium, we recommend that a water softener is used in areas where hard water is present. Contact your local
water equipment system provider to assist you in determining your specic water quality, or contact Star
Technical
support for assistance, 1-800-807-9054.
Direct Connect Water Supply Installation
1. Make certain the water valve that will be suppling the unit is turned off.
2. Connect the 1/4" I.D. exible tubing source and secure with clamps provided.
3. Holding the end opposite end over
(this removes any air from the system and ushes it of any particles that may be present).
4. Turn off the water valve.
5. Push the check valve tting into the water inlet located on the rear of the unit.
Make
6. Turn on water valve, Turn the knob on the regulator until the guage reads 26 psi. Check
to the outlet side of the water
a bucket, turn the water valve on until there is a good consistent supply of water
certain the connection is securely attached by lightly tugging on it.
for leaks.
Reservoir Water Units
1. With unit in nal position, open reservoir lid.
2. Check and make sure the reservoir is free of debris and material that may interfere with its operation.
3. The unit comes with a washer strainer which ts
over the water inlet
(see illustration), correctly in position. Periodically check strainer and clean and replace as often as necessary.
4. Pour tap water into reservoir until the water level is from the top.
1/4"
5. Closed lid.
6. Check water level during daily operation and ll as needed.
verify this is
6
Page 7
OPERATING PROCEDURE
Connect your unit to a wall outlet which will supply the unit with the proper voltage specied on the data
plate. If you have a reservoir unit, verify the water level, add if water is low.
CAUTION
KEEP HANDS AND FACE AWAY FROM THE UNIT WHEN OPENING OR REMOVING THE SPATULA FROM THE UNIT. STEAM ESCAPING IS VERY HOT.
MANUAL CONTROL
• Turn unit on
Wait 20 - 30 minutes for the unit to reach its operating temperature before using.
Note: The Temperature Set Point is factory xed at 400°F (204°C) and is not adjustable.
Place product in cooking chamber and hit the Steam Shot button to steam the product.
Steam Shot: Pressing the Green Steam Shot Green Button will release water in to the steam generator
and will instantly produce steam. Water will only stop when the button is released. Flooding of the steam generator may occur if the Steam Shot button, or the SST is set to high. When this occurs wait for the unit to work through the water before applying more water
to the steam generator.
ELECTRONIC CONTROL
• Turn unit on
Current Temperature will Flash on LED, PRESS the
TEMP button to see current temperature TCT will FLASH until TSP (Temperature Set Point) is reached, Alarm will sound 3-times when TSP is reached.
Note: The Temperature Set Point is factory xed at 400°F (204°C) and is not adjustable.
Place product in cooking chamber and choose one of the 4 pre-determined programmed
settings, or hit
• When program timing is completed, an alarm will sound.
the Steam Shot steam button to steam the product.
PROGRAMMING DEFINITIONS
TCT Total Cook Time SIT Shot Interval Time SST Steam Shot Time TSP Temp Set Point
Steam Shot: Pressing the Green Steam Shot Button will release water in to the steam generator and
will instantly produce steam. Water will only stop when the button is released. Flooding of the steam generator may occur if the Steam Shot button, or the SST is set to high. When this occurs wait for the
unit to vaporize all of the water before applying more water to the steam generator.
TIMER & STEAMER CONTROLLER OPERATION SPECIFICATIONS Startup:
1. The preset time will ash until the operating temperature is reached.
2. When the control reaches preset temperature, time display, "Heat On" indicator and program
indicator will stop ashing and the alarm will beep three times.
Temperature:
1. To view the actual steam generator temperature, press and hold "Temp Button."
7
Page 8
OPERATION continued
90 degrees
60 degrees
Cover
Stop
IL1366
To Program Time:
The program buttons factory pre-set are listed below. If changes are required follow these simple steps. Note, any changes to these
PROGRAMMING SPECIFICATIONS / RANGE
TCT Total Cook T SIT Shot Interval Time .5sec to 10 minutes SST Steam Shot Time .1 sec to 5.minutes TSP Temp Set Point
settings are stored in the units memory until changed. Returning to the factory pre-sets is not
available automatically.
1. Press and hold "TEMP"
(actual temperature displays).
2. While holding "TEMP,"
program button for one second, to begin
press and hold any
TCT 20 sec 40 sec 1 min 1.30 min
SIT 20
SST .5
programming
3. TCT (Total Cook Time) will
display, adjust
time with the "3 or 4" buttons.
• Press the #1 button to move to between minutes and seconds.
• Press the #1 button to move to SIT.
4. SIT
(Shot Interval Time) will
display, adjust time with the "3 or 4" buttons.
• Press the #1 button to move to between minutes and seconds.
• Press the #1 button to move to SST.
5. SST
(Steam
Shot Time) will display, adjust time with the "3 or 4" buttons.
ime 0 to 99.59 minutes
Program Button Factory Presets
1 2 3 4
sec 40 sec 40 sec 40 sec
sec .5 sec .5 sec .5 sec
• Press the #1 button to move to seconds.
6. Press
the "TEMP" button
to save time settings and to exit programming mode for this
program. Your program will not be saved if this step is not done within 10 seconds.
7. Repeat
process to program for additional programming
Hi-Limit Reset
A hi-limit reset monitors the temperature of the steam generator and will turn the power off to the unit to prevent it from overheating. If this occurs, the unit will automatically reset when it has had enough time to cool prior to returning to operation. If this occurs on a regular basis it may be a sign of a larger problem, call
your service agent or Star Manufacturing at
1-800-807-9054.
TOP LOADING COVER STOP
SETTINGS
Top Loading Fast Steamer models
(FS1 & FS2) are designed with
adjustable cover stops located on
the back of the units. As shown
here you can adjust your unit's
top cover between an opening
of 60° - 90°.
8
Page 9
CLEANING
CAUTION
DO NOT USE CAUSTIC CLEANERS, USE A MILD DETERGENT TO WIPE DOWN EXTERIOR SURFACES, CLEAN WITH DAMP
CLOTH
Daily
1. Turn the unit OFF & unplug the unit from its power source before proceeding with any service
or cleaning procedure.
2. Remove and clean the removable items listed on the maintenance components illustration for
your specic model. Clean using warm water and mild detergent. DRY parts completely
3. Wipe the exterior or the steamer with a damp cloth, then wipe dry. Note: drying all pieces
after cleaning will protect your nish from discoloration, any discoloration as a result from not
drying the equipment is not covered under warranty
4. Reinstall
the unit, beginning with the Steam Vent.
Monthly
The Star Fast Steamer generates instant steam by means of its open generator, however the mineral deposits in the water are left behind. A certain amount of deposits are needed for proper operation, but a build-up of calcium & mineral deposits may cause poor performance. It is important to properly maintain
you steamer to ensure quality operation. Depending on your specic water conditions and possibly any water ltration systems, you may need to clean your steamer more or less frequently.
.
CAUTION
DO NOT IMMERSE OR LET THE UNIT STAND IN WATER. DO NOT HOSE DOWN THE UNIT. KEEP THE UNIT AWAY FROM RUNNING WATER.
DO NOT SPLASH THE CONTROL HOUSING CERTAIN WATER CONDITIONS MAY REQUIRE MORE FREQUENT CLEANING.
WARNING
BEFORE CLEANING MAKE SURE POWER IS TURNED OFF AND UNIT IS UNPLUGGED.
CAUTION
IF A CHEMICAL CLEANER / DELIMER IS USED, BE CERTAIN IS IT SAFE FOR CAST ALUMINUM. FOLLOW PROCEDURES, PRECAUTIONS PROVIDED WITH THAT SPECIFIC PRODUCT.
9
Page 10
Cleaning Steam Generator
Steam Generator
Steam Ports
Water Inlet
IL1359
Wing Nut Generator
Cover
Diffuser
IL1377
1. Turn the unit OFF & unplug the unit from its power source.
2. Remove and clean the removable items listed on the maintenance components
illustration for your specic model. Clean
ing warm water and mild detergent.
us DRY parts completely.
3. With the steam generator cool, use a wire brush or scrapper to loosen the mineral/ calcium deposits on the generator surface and steam ports. Remove the loose built­up particles from the surface and wipe area clean with damp cloth and reassemble the unit.
NOTE: A certain needed on the steam generator to ensure proper steaming characteristics. If during cleaning, the surface becomes free of all calcium/mineral deposits, add tap water to the generator surface and allow it to boil off. In soft water conditions,
amount of calcium deposits are
Above: Inspect these area making sure they are clean of deposits.
Below: Reinstall these parts before foperating the steam feature during the cleaning procedure.
a small amount of lime will season it. (Seasoning Mixture, .75 oz. baking soda, .75 oz. lime, 1 quart water), use enough to cover bottom of the steam generator, turn unit on and allow to evaporate.
Excessive Mineral Build-up
4. Use
a delimer solution, which is safe for cast aluminum, on the steam generator surface. Follow the instruction provide with the delimer solution.
5. Use
a dry towel or sponge to remove the delimer solution, then rinse with clean water.
6. Install the diffuser, generator cover secure with the wing nut as shown here.
6. Plug
the steamer power cord into
power supply, and turn unit on.
the
7. Allow unit to reach operating temperature.
KEEP HANDS AND FACE AWAY
CAUTION
FROM THE UNIT WHEN OPERATING THE UNIT. STEAM ESCAPING IS VERY HOT.
8. Push the Green "Steam Shot" button several times to operate the steamer. This removes any delimer solution from the generator surface.
9. Turn unit off, reinstall all remaining parts and return unit to operation.
10
Page 11
Rack
Spatula
Drip Pan
Food Compartment
Steam Generator
Steam Ports
Diffuser
Generator Cover
Top Cover
Steam Vent
Wing Nut
Liner
Typical Front Loading Steamer Shown
IL1352
CLEANING FRONT LOADING STEAMER COMPONENTS ILLUSTRATION
11
Page 12
OPERATION TROUBLESHOOTING
DIAGNOSTICS FOR ELECTRONIC CONTROL STEAMERS
Shorted Temperature Probe
Open-Circuit T
No Heat/No Steam
Relay
Malfunction
Heat / No Steam Temperature
emperature Probe
To Cool
Less than 50 Ohms of resistance, if
a temperature probe is detected, the
output power will be shut-off to all relays.
if a temperature probe is detected, the
output power will be shut-off to all relays.
If relay malfunction is detected when the
temperature is below 150°F (66°C) for 30 minutes or reaches 500°F (260°C).
The output power will be shut-off to both
relays unit the error no longer occurs.
Probe Temperature is 200°F (93°C) less
than the programmed set point.
Press the “TEMP” switch,
the LED will display
“PrOB”
Press the “TEMP” switch,
the LED will display
“PrOB”
The display will blink
“rELY”
Program & Heat Indicator
Light will Flash.
If unit still does not operate contact the factory or one of its representatives or a local service company for service or required maintenance.
12
Page 13
Part# 2M-4497-2 12/06 RMS
The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty.
FOR ASSISTANCE
Should you need any assistance regarding the Operation or Maintenance of any Star equipment; write, phone, fax or email our Service Department.
In all correspondence mention the Model number and the Serial number of your unit, and the voltage or type of gas you are using.
ALL: * Pop-Up Toasters * Butter Dispensers * Pretzel Merchandisers
(Model 16PD-A Only)
* Pastry Display Cabinets * Nacho Chip Merchandisers * Accessories of any kind * Sneeze Guards * Pizza Ovens
(Model PO12 Only)
* Heat Lamps * Pumps-Manual
Visit our Website at: www.star-mfg.com Email: service@star-mfg.com
THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL
This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the transportation company who delivered the item to you and initiate your claim with same. If this procedure is not followed, it may affect the warranty status of the unit.
LIMITED EQUIPMENT WARRANTY
All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies. Models that are considered portable (see below) should be taken to the closest Star service agency, transportation prepaid.
> Star will not assume any responsibility for loss of revenue. > On all shipments outside the United States and Canada, see International Warranty. * The warranty period for the JetStar six (6) ounce & Super JetStar eight (8) ounce series popcorn machines is two (2) years. * The warranty period for the Chrome-Max Griddles is ve (5) years on the griddle surface. See detailed warranty provided with unit. * The warranty period for Te on/Dura-Tec coatings is one year under normal use and reasonable care. This warranty does not apply if damage occurs to
Te on/Dura-Tec coatings from improper cleaning, maintenance, use of metallic utensils, or abrasive cleaners, abrasive pads, product identi ers and point-of-sale attachments, or any other non-food object tha comes in continuous contact with the roller coating. This warranty does not apply to the
“non-stick” properties of such materials.
> This warranty does not apply to "Special Products" but to regular catalog items only. Star's warranty on "Special Products" is six (6) months on parts
and ninety (90) days on labor.
> This warranty does not apply to any item that is disassembled or tampered with for any purpose other than repair by a Star Authorized Service Center or
the Service Center's sub-agency.
> This warranty does not apply if damage occurs from improper installation, misuse, wrong voltage, wrong gas or operated contrary to the Installation and
Operating instructions.
> This warranty is not valid on Conveyor Ovens unless a "start-up/check-out" has been performed by a Factory Authorized Technician.
PARTS WARRANTY
Parts that are sold to repair out of warranty equipment are warranted for ninety (90) days. The part only is warranted. Labor to replace the part is chargeable to the customer.
SERVICES NOT COVERED BY WARRANTY
PORTABLE EQUIPMENT
Star will not honor service bills that include travel time and mileage charges for servicing any products considered "Portable" including items listed below. These products should be taken to the Service Agency for repair:
1. Travel time and mileage rendered beyond the 50 mile radius limit
2. Mileage and travel time on portable equipment (see below)
3. Labor to replace such items that can be replaced easily during a daily cleaning routine, ie; removable kettles on fryers, knobs, grease drawers on griddles, etc.
4. Installation of equipment
5. Damages due to improper installation
6. Damages from abuse or misuse
7. Operated contrary to the Operating and Installation Instructions
8. Cleaning of equipment
9. Seasoning of griddle plates
10. Voltage conversions
11. Gas conversions
12. Pilot light adjustment
13. Miscellaneous adjustments
14. Thermostat calibration and by-pass adjustment
15. Resetting of circuit breakers or safety controls or reset buttons
16. Replacement of bulbs
17. Replacement of fuses
18. Repair of damage created during transit, delivery, & installation OR created by acts of God
* The Model 510FD Fryer. * The Model 526TOA Toaster Oven. * The Model J4R, 4 oz. Popcorn Machine. * The Model 518CMA & 526CMA Cheese Melter. * The Model 12MC & 15MC & 18MCP Hot Food Merchandisers. * The Model 12NCPW & 15NCPW Nacho Chip/Popcorn Warmer. * All Hot Dog Equipment except Roller Grills & Drawer Bun Warmers. * All Nacho Cheese Warmers except Model 11WLA Series Nacho Cheese Warmer. * All Condiment Dispensers except the Model HPD & SPD Series Dispenser. * All Specialty Food Warmers except Model 130R, 11RW Series, and 11WSA Series. * All QCS/RCS Series Toasters except Model QCS3 & RCS3 Series.
13
Page 14
SK2250 Rev. C 8/30/2007
Sheet 1 of 8
WIRING DIAGRAM
FS1DT & FS2DT
COMPLETE
A
4
2
E11
E12
E1
E2
E3
E4
E7 E6 E5
RTD PROBE
1
NC3
N02
COM
6
5
2
7
3
3
3
7
8
B
B
A
3
8
9
1
1
1
2
2
1
2
6
5
ELECTRONIC
CONTROL
(BACK SIDE)
PUSH BUTTON
POWER
SWITCH
HEATER RELAY
HIGH LIMIT
THERMOSTAT
TRANSFORMER
120V/10V
120V
SOLENOID
CONTROL BOX
MOUNTING PLATE
CONTROL PANEL
MOUNTING PLATE
HEATING
ELEMENT
4
BLACK WIRE (TYP)
WHITE WIRE (TYP)
SOLENOID
RELAY
10
10
10
10
CORDSET
120V: NEMA 5-15P
(SHOWN)
120VC: NEMA 5-20P
(NOT SHOWN)
B
14
Page 15
SK2250 Rev. C 8/30/2007
Sheet 2 of 8
WIRING DIAGRAM
FS1RT & FS2RT
COMPLETE
2
E11
E12
E1
E2
E3
E4
E7 E6 E5
RTD PROBE
1
NC3
N02
COM
6
5
2
7
3
3
3
7
8
B
3
8
9
1
1
1
2
2
1
2
6
5
ELECTRONIC
CONTROL
(BACK SIDE)
PUSH BUTTON
POWER
SWITCH
HEATER RELAY
TRANSFORMER
120V/10V
PUMP
RELAY
CONTROL BOX
MOUNTING PLATE
CONTROL PANEL
MOUNTING PLATE
B
120V PUMP
2
DIODE AND WIRE
PART OF PUMP
HEATING
ELEMENT
BLACK WIRE (TYP)
WHITE WIRE (TYP)
HIGH LIMIT
THERMOSTAT
10
10
10
10
CORDSET
120V: NEMA 5-15P
(SHOWN)
120VC: NEMA 5-20P
(NOT SHOWN)
B
15
Page 16
SK2250 Rev. C 8/30/2007
Sheet 3 of 8
WIRING DIAGRAM
FS1D & FS2D
1
1
2
2
4
2
NC3
N02
COM
PUSH BUTTON
A
B
2
1
3
4
CONTROL BOX
MOUNTING PLATE
HIGH LIMIT
THERMOSTAT
STEAM GENERATOR
THERMOSTAT
HEATING
ELEMENT
120V SOLENOID
(SHOWN ON SIDE)
POWER
SWITCH
CONTROL PANEL
MOUNTING PLATE
BLACK WIRE (TYP)
WHITE WIRE (TYP)
CORDSET
120V: NEMA 5-15P
(SHOWN)
120VC: NEMA 5-20P
(NOT SHOWN)
B
3
1
A
C
C
16
Page 17
WIRING DIAGRAM
FS1R & FS2R
SK2250 Rev. C 8/30/2007
Sheet 4 of 8
1
1
2
2
NC3
N02
COM
PUSH BUTTON
B
2
1
3
CONTROL BOX
MOUNTING PLATE
STEAM GENERATOR THERMOSTAT
STD MOUNTED ABOVE HIGH LIMIT
HEATING
ELEMENT
POWER
SWITCH
CONTROL PANEL
MOUNTING PLATE
3
1
B
STEAM GENERATOER HIGH LIMIT THERMOSTAT
STD MOUNTING BELOW THERMOSTAT
2
BLACK WIRE (TYP)
WHITE WIRE (TYP)
CORDSET
120V: NEMA 5-15P
(SHOWN)
120VC: NEMA 5-20P
(NOT SHOWN)
17
Page 18
SK2250 Rev. C 8/30/2007
WIRING DIAGRAM
FSFDT
Sheet 5 of 8
NEMA 6-20P
CORDSET
FOR 208/240V
E11
E12
E1
E2
E3
E4
E7 E6 E5
RTD PROBE
NC3
N02
COM
6
5
2
7
3
3
3
7
8
B
3
8
9
1
1
1
2
2
2
6
5
ELECTRONIC
CONTROL
(BACK SIDE)
PUSH BUTTON
POWER
SWITCH
HEATER RELAY
TRANSFORMER
230V/10V
CONTROL BOX
MOUNTING PLATE
CONTROL PANEL
MOUNTING PLATE
1
5
5
6
HEATING
ELEMENT
SOLENOID
STD
MOUNTING
POSITION
(SHOWN ON
SIDE).
4
4
A
B
A
SOLENOID
RELAY
12 V
SOLENOID
HIGH LIMIT
THERMOSTAT
BLACK WIRE (TYP)
WHITE WIRE (TYP)
10
10
10
10
18
Page 19
SK2250 Rev. C 8/30/2007
Sheet 6 of 8
WIRING DIAGRAM
FSFD
NEMA 6-20P
1
1
2
2
B
3
1
A
5
2
NC3
N02
COM
PUSH BUTTON
A
CORDSET FOR
208/240V
B
2
4
3
5
CONTROL BOX
MOUNTING PLATE
HIGH LIMIT
THERMOSTAT
STEAM GENERATOR
THERMOSTAT
HEATING
ELEMENT
POWER
SWITCH
CONTROL PANEL
MOUNTING PLATE
12 V SOLENOID
(SHOWN ON SIDE)
6
6
4
BLACK WIRE (TYP)
WHITE WIRE (TYP)
C
C
19
Page 20
SK2250 Rev. A 8/3/2007
Sheet 7 of 8
WIRING DIAGRAM
FSFRT
NEMA 6-20P
CORDSET
FOR 208/240V
E11
E12
E1
E2
E3
E4
E7 E6 E5
RTD PROBE
NC3
N02
COM
6
5
2
7
3
3
3
7
8
B
3
8
9
1
1
1
2
2
2
6
5
ELECTRONIC
CONTROL
(BACK SIDE)
PUSH BUTTON
POWER
SWITCH
HEATER RELAY
TRANSFORMER
40 VA 230V/12V
PUMP
RELAY
CONTROL BOX
MOUNTING PLATE
CONTROL PANEL
MOUNTING PLATE
B
12V PUMP
6
DIODE AND WIRE
PART OF PUMP
1
SEE
DETAIL
A
5
5
6
HEATING
ELEMENT
A & B - 1/4" MALE
W/BLACK WIRE LEADS
C & D - 3/16" MALE
W/WHITE WIRE LEADS
DETAIL A
TRANSFORMER
INLINE FUSEHOLDER
W/4AMP FUSE
HIGH LIMIT
THERMOSTAT
BLACK WIRE (TYP)
WHITE WIRE (TYP)
10
10
10
10
20
Page 21
WIRING DIAGRAM
FSFR
SK2250 Rev. C 8/30/2007
Sheet 8 of 8
NEMA 6-20P
1
1
2
2
NC3
N02
COM
PUSH BUTTON
CORDSET FOR
208/240V
B
2
3
CONTROL BOX
MOUNTING PLATE
STEAM GENERATOR THERMOSTAT
STD MOUNTED ABOVE HIGH LIMIT
HEATING
ELEMENT
POWER
SWITCH
CONTROL PANEL
MOUNTING PLATE
3
1
B
STEAM GENERATOER HIGH LIMIT THERMOSTAT
STD MOUNTING BELOW THERMOSTAT
2
SEE
DETAIL
A
1
DIODE AND WIRE
PART OF PUMP
INLINE FUSEHOLDER
W/4AMP FUSE
12 V PUMP
BLACK WIRE (TYP)
WHITE WIRE (TYP)
A & B - 1/4" MALE
W/BLACK WIRE LEADS
C & D - 3/16" MALE
W/WHITE WIRE LEADS
DETAIL A
TRANSFORMER
B
21
Page 22
STAR MANUFACTURING INTERNATIONAL, INC.
Front Loading Steamer Main Body Assembly
Rev. A 10/31/07SK2276
MODEL: FSF
1
3
2
4
18
5
8
6
12
13
11
10
9
11
14
7
15
16
17
19
20
21
22
Page 23
PARTS LIST July 27, 2009, Rev. E
FSFR, FSFD, FSFRT, FSFDT, Front Loading Fast Steamer Main Body
MODEL
Number
Key
Number
1 C9-Z10101 1 TOP FRONT LOADING 2 2C-Z10133 2 NUT, WING 10-24 SS FRONT LOADING 3 C9-Z10095 1 COVER, CASTING FRONT LOADING 4 C9-Z10096 1 DISPERSER FRONT LOADING
5 2C-08-07-0285 1 SCREW 10-24X3/4X3/8 TYPE 2 HEX DBL END STL FRONT LOADING
6 C9-Z10069 1 RACK, WIRE STEAMER FRONT LOADING
6 C9-FS0313 1 LINER ASSEMBLY FSF STEAMER FRONT LOADING 7 C9-FS0373 1 SPATULA ASSEMBLY FRONT LOADING 8 2B-Z10069 1 SPATULA WIRE ASSY FRONT LOADING
9 2C-Z11259 1 BOLT CARRIAGE 3/8-16X1" SS FRONT LOADING 10 2A-Z11257 1 SPATULA HANDLE TUBE FRONT LOADING 11 2A-Z11258 2 SPATULA ANGLED WASHER FRONT LOADING 12 C9-Z10103 1 SPATULA FRONT LOADING 13 C9-Z9990 1 SPATULA FRONT FRONT LOADING 14 2R-09-WB-0027 1 HANDLE-BLK 3/8-16 HD698 FRONT LOADING
15 C9-Z10105 1 DRIP TRAY FRONT LOADING
16 2C-Z6925 6 SCREW,#8 X.5 TEK HW SS FRONT LOADING
17 C9-Z11250 1 DRIP TRAY SUPPORT FSF FRONT LOADING
18 2A-Z9989 4 FOOT, 2" STEAMER FRONT LOADING
19 C9-FS0301 1 VENT ASSEMBLY FRONT LOADING 20 C9-FS0344 1 FSF CASTING ASSEMBLY 208V FRONT LOADING 208V 20 C9-FS0345 1 FSF CASTING ASSEMBLY 230V FRONT LOADING 230/240V
21 2C-3033 12 SCREW-MACH 8-32X3/4 NPST FRONT LOADING
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
23
Page 24
STAR MANUFACTURING INTERNATIONAL, INC.
Main Body Assembly
Rev. - 7/31/07SK2281
MODEL FS1 & FS2
1
2
3
4
5
6
7
8
10
9
11
12
13
14
17
16
15
16
20
22
21
18
23
19
21
24
Page 25
PARTS LIST July 27, 2009, Rev. E
MODEL
FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT Top Loading Fast Steamer Main Body
Number
Key
Number
1 2C-4063 AR SCREW 10-24X1/2 SS THP FS1 & FS2
2 C9-FS0364 1 COVER SKIN ASSY FS1 C9-FS0365 1 COVER SKIN ASSY FS2
3 2C-Z9982 1 SCREW 3/8-16X1 PHFHMS SS FS1 & FS2 4 2A-Z9955 1 HANDLE MOUNTING BLOCK FS1 & FS2 5 2R-09-WB-0027 1 HANDLE-BLK 3/8-16X1 PHFHMS SS FS1 & FS2 6 2C-9042 3 SCREW 10-24X.75 FH SS FS1 & FS2 7 C9-FS0315 1 INSIDE COVER INSERT FS2 FS2 C9-FS0316 1 INSIDE COVER INSERT FS1 FS1 8 2I-Z10033 1 FS2 COVER GASKET W/CLIPS FS2 2I-Z10034 1 FS1 COVER GASKET W/CLIPS FS1 9 2B-Z10067 1 BOTTOM GRATE FOR 1/2 PAN FS1 2B-Z5847 1 BUN RACK (SMALL) FS2 10 2D-Z10054 1 1/2 PAN 2.5DP PERF SIDES - FS1 2D-Z10241 1 PAN, 2/3 PERFORATED FS2 11 2C-Z4251 2 SCREW 8-32X3/8 RHP SS FS1 & FS2 12 C9-Z9987 1 COVER DRIP CATCH FS1/2 FS1 & FS2 13 C9-Z10488 1 PROBE HOLDER FS1/FS2 E/C - FS1RT, FS2RT, FS1DT, FS2DT 14 2C-1487 1 SCREW 6-32X1/4 RHP STL NP FS1RT, FS2RT, FS1DT, FS2DT 15 C9-Z10174 1 BOTTOM FS2 FS2 C9-Z10175 1 BOTTOM FS1 FS1 16 2C-Z6925 14 SCREW #8 X 1/2 HEX WB SS FS1 & FS2 2C-Z6925 10 SCREW,#8 X.5 TEK HW SS FS2 17 2A-Z3828 4 1" SOLID LEG FS1 & FS2 18 C9-Z10482 1 ELEMENT INSULATION FS1 FS1D, FS1DT, FS1R, FS1RT C9-Z10483 1 ELEMENT INSULATION FS2 FS2D, FS2DT, FS2R, FS2RT 19 2C-Z2893 4 NUT 10-24 HEX STL ZP 9/16 WASHER FS1 & FS2 20 C9-Z10153 2 STEAM GENERATOR SUPPORT FS1 FS2 STEAMER FS1 & FS2 21 C9-Z10336 2 ELEMENT RETAINER FS1 FS1 C9-Z10337 2 ELEMENT RETAINER FS2 FS2 22 2A-Z6604 4 SPACER, INSULATION PLATE FS1 & FS2 23 2N-Z9983 1 ELEMENT FS1 120V 1800W FS1-120V 2N-Z9984 1 ELEMENT FS2 120V 1800W FS2-120V
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
25
Page 26
STAR MANUFACTURING INTERNATIONAL, INC.
Control Box Assemblies Direct Connect Water Supply
Rev. A 7/9/08SK2277
MODEL Fast Steamer
1
37
1
2
3
4
29
5
28
6
9
10
11
13
12
12
14
15
16
16
13
11
7
30
28
32
33
33
28
28
36
32
31
8
1
22
23
24
Electronic Controls
Manual Controls
Top Loading
Front Loading
26
Page 27
STAR MANUFACTURING INTERNATIONAL, INC.
Control Box Assemblies Reservoir Water Supply
Rev. - 7/16/08SK2385
MODEL Fast Steamer
6
5
11
13
12
12
14
15
16
16
13
11
32
28
30
29
39
33
35
34
38
33
36
27
32
31
28
1
10
19
17
2
20
21
7
22
3
26
8
3
23
24
1
Electronic Controls
Top Loading
Front Loading
Manual Controls
27
Page 28
PARTS LIST July 27, 2009, Rev. E
FSFR, FSFD, FSFRT, FSFDT, FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT
MODEL
Top & Front Loading Fast Steamer Control Box Assemblies
Number
Key
Number
1 2C-Z4063 AR SCREW 10-24X1/2 SS THP 18-8 OR 300 SERIES 2 C9-FS0300 1 CB COVER ASSY DC DIRECT CONNECT FS1DT-120V,FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V
C9-FS0377 1 CB COVER ASSY STMR W/RES FS1RT-120V, FS2RT-120V, FSFRT-208/240V, 3 2E-Z10158 2 RELAY, DPST-NO SEALED FS1DT-120V, FS2DT-120V, FSFDT-208/240V,
FS1RT-120V, FS2RT-120V, FSFRT-208/240V 4 2V-Z9981 1 SOLENOID VALVE 120V STMR FS1DT-120V, FS2DT-120V, FS1D-120V, FS2D-120V 2V-Z9988 1 SOLENOID VALVE 12V FSFD-208/240V FSFDT-208/240V 5 2T-Z10248 1 THERMOSTAT, 122F-483F FS1D, FS2D, FSFD, FS1R, FS2R, FSFR 2T-Z10839 1 HL THERMOSTAT CAP-570 FSFD-208V 6 2T-Z10839 1 HL THERMOSTAT CAP-570 ALL 7 2E-05-07-0350 1 TRANSFORMER 230V/10V 6VA FSFD-208/240V, FSFDT-208/240V 2E-05-07-0351 1 TRANSFORMER 115/10V 6VA FS1RT-120V, FS2RT-120V, FS1DT-120V,
2E-Z10170 1 TRANSFORMER, 40V 12V 115/230 FSFRT-208/240V, FSFR-208/240V
8 C9-FS0317 1 CB BTM ASSY FSF DC EC FSFDT-208/240V C9-FS0335 1 CB BTM ASSY FS1/2 DC MAN FS1D-120V, FS2D-120V C9-FS0339 1 CB BTM ASSY FS1/2 DC EC FS1DT, FS2DT C9-FS0341 1 CB BTM ASSY FS1/2 R EC FS1RT, FS2RT C9-FS0343 1 CB BTM ASSY FS1/2 R MAN FS1R, FS2R C9-FS0351 1 CB BTM ASSY FSF DC MAN FSFD-208/240V C9-FS0352 1 CB BTM ASSY FSF R EC FSFRT-208/240V C9-FS0360 1 CB BTM ASSY R MAN FSFR-208/240V
9 2K-Z10080 1 Q-D FEMALE/3/8 HOSE PANEL FS1DT-120V,FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V 10 C9-FS0311 1 CNTR BOX BACK ASSY FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V C9-FS0314 1 CB BACK PNL ASSY DC FS1DT-120V,FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V 11 2E-Z1858 1 SWITCH-LIGHTED ALL 12 2M-Z10244 1 CNTR PANEL LABEL E/C FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V 12 2M-Z10245 1 CNTR PANEL LABEL MANUAL FS1D-120V, FS2D-120V, FSFD-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 13 C9-FS0320 1 CNTR PANEL ASSY E/C FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V C9-Z10484 1 CNTR PANEL ASSY M/C FS1D-120V, FS2D-120V, FSFD-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 14 2K-Z1971 4 SPACER .257X.75X.25 NYLON FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V 15 2J-Z9794 1 STMR CNTR BOARD FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V
16 2E-Z9991 1 SNAP PUSHBUTTON ASSY ALL
17 C9-Z10486 1 TANK LID FSF FS1/2 STMR FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 19 A3-35219 1 CAP & CHAIN FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 20 2C-Z2893 1 NUT 10-24 HEX STL ZP 9/16 WASHER FSFD-208/240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V 21 C9-Z10481 1 PROBE/BULD HOLD DOWN BRKT FSFD-208/240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V
Part
Number
FS1R-120V, FS2R-120V, FSFR-208/240V
FS2DT-120V
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
28
Page 29
PARTS LIST July 27, 2009, Rev. E
FSFR, FSFD, FSFRT, FSFDT, FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT
MODEL
Top & Front Loading Fast Steamer Control Box Assemblies
Number
Key
Number
22 A5-RG2036 1 CORD SET 120V W/TERMINALS, 120V C9-FS0357 1 CORD SET 120VCSA 120VC C9-FS0362 1 CORD SET 12/3 6-20 6' , 208/240V 208/240V 23 2K-Z2895 1 BUSHING HEYCO OCB-500 FS1D, FS1DT, FS1R, FS1RT, FS2D, FS2DT, FS2R, FS2R
23 2K-Y6764 1 BUSHING - STRAIN RELIEF FSFD, FSFDT, FSFR, FSFRT
24 C9-FS0359 1 CORD SET 14/3 5-20P 6FT 120V-CUL C9-Z10457 1 CORDSET MTG PLATE .88X.77 FS1D-120V, FS1DT-120V, FS1R-120V, FS1RT-120V,
C9-Z10458 1 CORDSET MTG PLATE .88X.844 FSFD-208240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V 26 C9-Z10220 2 PUMP MOUNTING STRAP FS1RT-120V, FS2RT-120V, FSFRT-208/240V,
27 2U-Z10070 1 WATER PUMP, STMR 12V FSFRT-208/240V, FSFR-208/240V 2U-Z9980 1 WATER PUMP, 120V FS1R-120V, FS1RS-120V, FS1RT-120V,
28 2C-Z10240 4 CLAMP, HOSE 7/16-25/32 FS1D-120V, FS1DT-120V, FS1R-120V, FS1RT-120V, FS2D-120V, FS2DT-120V, FS2R-120V, FS2RT-120V 2C-Z10240 8 CLAMP, HOSE 7/16-25/32 FSFD-208/240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V 29 C9-Z10237 1 PUMP INLET HOSE FS1R, FS1RT, FS2R, FS2RT, FSFR, FSFRT C9-Z10246 1 SOLENOID INLET HOSE FS1DT­ 30 C9-Z10238 1 FSF PUMP OUTLET HOSE FSF STMR FSFRT-208/240V, FSFR-208/240V C9-Z10247 1 FS1/FS2 OUTLET HOSE FS1/FS2 C9-Z10456 1 FSF SOK OUT / TEE OUT HOSE FSFD, FSFDT 31 2K-Z9986 1 UNION TEE, 3/8 SLIP-ON DBL HSE BARB-STMR FSFD-208V 32 C9-Z10456 2 FSF SOL OUT/TEE OUT HOSE FSF STMR FSFD-208/240V, FSFDT-208/240V C9-Z10456 1 FSF SOL OUT/TEE OUT HOSE FSF STMR FSFR-208/240V, FSFRT-208/240V 33 2A-Z9972 2 NIPPLE, PTFE 5.5" FSFD, FSFDT, FSFR, FSFRT 34 2E-Z10855 1 FUSE 4AMP .25X1.25 FSFRT-208/240V, FSFR-208/240V
35 C9-FS0308 1 FUSEHOLDER WIRE ASSY F/F FSFRT-208/240V C9-FS0330 1 FUSEHOLDER WIRE ASSY M/F FSFR-208/240V
36 2K-Z9978 1 HALF NIPPLE 1/8X2.5 FS1D, FS1DT, FS1R, FS1RT, FS2D, FS2DT, FS2R, FS2RT 37 2V-Z10448 1 STMR WATER SUPPLY HOSE FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V 38 2E-Z3278 1 RTD PROBE - 48" LONG WIRE FS1DT, FS2DT, FS1RT, FS2RT, FSFDT, FSFRT 39 2I-Z11785 1 STRAINER, WASHER FS1RT-120V, FS2RT-120V, FSFRT-208/240V,
Part
Number
FS2D-120V, FS2DT-120V, FS2R-120V, FS2RT-120V
FS1R-120V, FS2R-120V, FSFR-208/240V
Per
Unit
Description and Model Designation
T
FS2RT-120V, FS2R-120V
FS1R-120V, FS2R-120V, FSFR-208/240V
2
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
29
Page 30
STAR MANUFACTURING INTERNATIONAL, INC.
Hinge Bracket Assembly
Rev. - 8/28/07SK2315
MODEL FS1 & FS2
9
8
7
5
4
6
3
2
2
1
30
Page 31
PARTS LIST July 27, 2009, Rev. E
FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT
MODEL
Top Loading Fast Steamer Hinge Assemblies
Number
Key
Number
1 2A-Z10454 1 CENTER HINGE PIN FS1 FS1 2A-Z10677 1 CENTER HINGE PIN FS2 FS2 2 2A-Z10214 2 PIN, SPRING STEAMER ALL FS1 & FS2 3 C9-Z10156 2 HINGE/COVER BRACKET ALL FS1 & FS2 4 2C-Z10215 8 COTTER PIN 18-8 5/16 .059 ALL FS1 & FS2 5 2A-Z9992 2 HINGE PIN, OUTSIDE ALL FS1 & FS2 6 2C-Z4063 AR SCREW 10-24X1/2 SS THP 7 2P-Z10217 2 FS1 FS2 HINGE SPRING ALL FS1 & FS2 8 2A-Z11241 8 SCREW SHLDR 8-32X3/16X3 ALL FS1 & FS2 9 C9-Z11242 2 HINGE STOP BRACKET ALL FS1 & FS2
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
31
Page 32
STAR MANUFACTURING GROUP
Star - Holman - Lang - Wells - Bloomeld
10 Sunnen Drive, St. Louis, MO 63143 U.S.A.
(800) 807-9054 (314) 781-2777
Parts & Service (800) 807-9054
www.star-mfg.com
Loading...