Star F40 Service Manual

90 INDUSTRIAL PARK ROAD, SACO, ME/U.S.A. 04072 (207) 282-1589 800-225-3958 FAX (207) 282-6283
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
(For Service Information Call: 800-225-3958)
TABLE OF CONTENTS
ASSEMBLY & INSTALLATION PAGE 1, 2
ELECTRICAL INSTALLATION PAGE 3
OVEN OPERATION PAGE 3
CLEANING (DAILY) PAGE 3
TROUBLE SHOOTING GUIDE PAGE 4 & 5
MAINTENANCE PROCEDURES PAGE 5, 6
PARTS LIST PAGE 7
DRAWINGS
HEATER TUBE INSTALLATION PAGE 2
LEFT SIDE EXPLODED VIEW PAGE 6
WIRING DIAGRAMS
F24(W), F36(W), F40(W) PAGE 8
F\MICHAEL\MANUALS\VAMANUAL\F36MAN.DOC HGO111 REV. 4/24/97 MJC
PAGE 1
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
UNCRATING AND INSPECTION
Unpack unit and components from container. Remove all visible packing material and inspect unit for damage. If damage is discovered, file a claim immediately with the carrier that handled the shipment.
ASSEMBLY AND INSTALLATION
A. Counter Mounting (models F24, F36, F40):
If the unit is to be installed on a counter, attach legs as shown below. Anti-skid pads are available at no charge and may be adhered to the foot section of each leg to prevent sliding. Call 1-800-225-3958 for details. (Caution: Use of these pads is not approved by the National Sanitation Foundation).
LEGS SCREW INTO LEG HOLES AT BOTTOM OF UNIT.
B. Wall Mounting (models F24W, F36W, F40W): Mounting bolts (2 1/2" lag bolts) have been supplied with your Cheese Melter. At the back of the Cheese Melter there are either two (F24) or three (F36) 5/8" holes which are plugged with nickel platted Button Plugs. These holes are on 16" centers and large enough so that the head of the Lag Bolt will slip inside the hole.
Screw the Lag Bolt into wall studs on 16" centers and level. Screw heads should be 1/8" away from the wall as shown below.
Using a flat tipped screw driver, the Button Plugs can be removed from the holes at the top rear of the unit. Unit may now be hung from wall by inserting the bolt heads into the mounting holes in the unit.
ASSEMBLY AND INSTALLATION CONTINUED ON PAGE 2
REVISED 3/30/00 MJC
PAGE 2
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
ASSEMBLY AND INSTALLATION CON'T.
C. Heater Tubes:
Models F24, F36, F40 and F24W, F36W, F40W use quartz sheathed Heater Tubes which are held in position by spring loaded Sockets which push on the end of the Heater Tubes. To install or remove a Heater Tube, grasp the end of the Heater Tube (NEVER THE MIDDLE), push one end of the Heater Tube into one of the spring loaded Sockets and insert or remove the other end of the Heater Tube into or out of the remaining Socket as shown below.
HEATER ELEMENT SOCKET END, MODEL F24 & F36
HEATER TUBE SOCKETS; METAL CONTACTS IN SOCKET
FACE SHOULD ALIGN WITH METAL FLANGE AT EACH END OF HEATER TUBE
HEATER SOCKET
WALL OF UNIT
: The F24, F36, F40 and F24W, F36W, F40W heater tubes are clear quartz (like glass) and quite fragile. When removing them from the cardboard tubes it is very important that no bending pressures be applied or they will immediately snap in the middle.
(EXTREME CAUTION SHOULD BE EXERCISED)
TUBES ARE VERY FRAGILE
REVISED 11/28/95 MJC
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
ELECTRICAL INSTALLATION
WARNING:
NEVER PLUG A 208 VOLT UNIT INTO 240 VOLTS OR A 240 VOLT UNIT INTO 208 VOLTS. CHECK WITH POWER COMPANY TO DETERMINE ACTUAL VOLTAGE AT THE JOB SITE BEFORE INSTALLING UNIT.
WARNING:
BE ABSOLUTELY SURE THE GROUND CONNECTION FOR THE RECEPTACLE IS PROPERLY WIRED. NEVER CONNECT UNIT TO POWER WITHOUT PROPER GROUND CONNECTIONS. IMPROPER GROUND CONNECTION MAY RESULT IN SEVERE INJURY OR FATALITY.
Models F24, F36 and F40 are furnished with a 4 foot cord and standard NEMA 6­30 Plug for plug in installation in a grounded 208 or 240 Volt outlet. Models F24W, F36W and F40W are furnished with a 1 1/2 foot cord and NEMA 6-30 Plug. Your HOLMAN oven should be the only appliance connected to the electrical line and should have its own fuse or breaker in the electrical box.
OVEN OPERATION
A. Pre-heat:
Put Power Saver Switch into the ON position and set front and rear heat controls to desired settings. Fan Motor will now run and Pilot Light turns on. Allow approximately five minutes for warm up time.
B. Power Saver:
Put power Switch into the off position. Pilot light is on and fan continues to run. Front two elements will now turn off while rear two elements continue to run. Unit is now in 1/2 power.
C. Cooking: There are six shelf positions in your Holman Cheese Melter (2 in model F40) with temperatures that range from approximately 300 deg. (F) in the lowest position to approximately 600 deg. (F) in the highest position. Some experimentation between heat control settings and shelf position may be necessary to achieve desired cooking results.
CLEANING (DAILY)
A. Turn Power Saver to the OFF possition. When oven has cooled;
1. Remove shelf or rack. Clean with hot soapy water.
2. Wipe interior and exterior surfaces with a damp cloth.
REVISED 11/27/95 MJC
PAGE 3
PAGE 4
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
TROUBLE SHOOTING GUIDE
CAUTION - ALWAYS DISCONNECT UNIT FROM POWER SOURCE BEFORE SERVICING
A. UNIT WILL NOT HEAT, FAN MOTOR WORKS.
MODELS F24, F36, F40 & F24W, F36W, F40W
1. Disconnect unit from power source and check if heaters are properly installed as shown on page 3.
2. Make sure Power Saver Switch is in the ON position.
3. Press Heat Limit Switch.(If this reactivates heaters, see HEAT LIMIT SWITCH section C ).
B. UNIT WILL NOT HEAT, FAN WILL NOT WORK, PILOT LIGHT WILL NOT COME ON.
1. Be sure main Circuit Breaker is switched to the ON position.
2. Check if oven is plugged in.
3. Make sure Power Saver Switch is in the ON position.
4. Call Holman Service Department at 1-800-225-3958 if further assistance is needed.
C. HEAT LIMIT SWITCH Your Holman oven is equipped with an automatically activated temperature (Heat) Limit Switch which interrupts the Heater Tube connections if the air temperature in the Control Box exceeds 190 degrees (F), 87.8 degrees (C). This Heat Limit switch can be reset manually by pushing a button located on the bottom of the unit as shown below.
RESET / HIGH LIMIT
THIS HEAT LIMIT SWITCH IS ACTIVATED WHEN THERE IS NOT A PROPER AMOUNT OF AIR FLOW BEING GENERATED BY THE COOLING FAN. IF THIS OCCURS:
1. DISCONNECT UNIT FROM POWER SOURCE.
2. Check to see if the air intake area (louvers in left side panel) is free of dust, grease or other obstructions.
Heat Limit Switch Continued On Page 5
REVISED 9/27/95 MJC
PAGE 5
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
HEAT LIMIT SWITCH CON'T.
3. If no obstruction to the Air Intake can be found, call the Holman Service Department for assistance at 1-800-225-3958.
D. NO HEAT IN POWER SAVER MODE
1. Disconnect unit from power source.
2. Check to make sure rear Heater Tubes are properly installed.
3. Call the Holman Factory Service Team for further assistance.
MAINTENANCE PROCEDURES
REPLACING HEATER TUBES
1. Disconnect unit from power source.
2. Gently
, pull defective Heater Tube out of unit by pushing from left to right,
then slowly guide Heater Tube out of unit.
3. Gently
, put new Heater Tube into unit by placing tube end into Socket and pushing into the spring loaded Socket. Guide opposite end of Heater into the remaining Socket.
HEATER ELEMENT SOCKET END, MODEL F24 & F36
HEATER TUBE SOCKETS; METAL CONTACTS IN SOCKET
FACE SHOULD ALIGN WITH METAL FLANGE AT EACH END OF HEATER TUBE
HEATER SOCKET
WALL OF UNIT
MAINTENANCE PROCEDURES CONTINUED ON PAGE 6 REV. 11/28/95 MJC
PAGE 6
5
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
MAINTENANCE PROCEDURES CONT.
B. REPLACING FAN MOTOR
1. Disconnect unit from power supply.
2. Remove Top Cover as shown below.
3. Carefully slide right Side Panel up and out away from unit. Fan Motor will be attached to Side Panel.
4. Disconnect motor lead from rear of Fan Motor.
5. Remove Fan Motor and Fan Grill from Side Panel by removing four Mounting Screws on Side Panel.
6. Attach new Fan Motor and Fan Grill to Side Panel with four Mounting Screws
7. Reconnect motor lead to rear of new Fan Motor.
8. Slide new Side Panel with new Fan Motor already attached onto side of unit.
9. Replace Top Cover.
REMOVE TOP COVER BY LIFTING UP AND PUSHING FORWARD
TOP COVER
12
11
10
SIDE PANEL
MOUNTING SCREWS
FAN CORD
4
6
7
8
9
1. MOUNTING BRACKET 2. SCREW
FAN MOTOR
3. RESET / HIGH LIMIT 4. HEATER SOCKET
5. ON / OFF SW ITCH 6. TOGGLE NUT
7. PILOT LIGHT 8. KNOBS, INFINITE SWITCH
9. POWER SAVER 10. POWER SUPPLY CORD
11. TERMINAL STRIP 7 POS. 12. TERMINAL STRIP 4 POS.
REV. 3/30/00 MJC
1
5
2
4
3
6
2
18
19
17
MODEL: MINIVEYOR
F24 & F36 (manufactured before 2/2000)
14
16
12
11
8
10
7
SK2157 Rev. - 12/16/05
1
This drawing contains information confidential to Star Manufacturing International, Inc. No reproduction or disclosure of its contents is permitted.
SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN CERTAIN INSTANCES MAY NOT BE AVAILABLE
2
18
2
5
4
3
6
17
8
19
MODEL: F24PS & F36PS
(manufactured after 2/2000)
20
21
15
10
13
7
SK2158 Rev. - 12/16/05
F24 - F36 Series Holman Finishing Ovens
Fig No.
1 FB-100801 1 TOP COVER 36” FA-100800 1 TOP COVER 24” 2 2E-200409 8 SOCKET, HEATER TUBE 3 FB-187708 4 HEATERTUBE QUARTZ F36 208V FB-187708 6 HEATERTUBE QUARTZ F36PSE 208V FB-187701 4 HEATERTUBE QUARTZ F36 220V FB-187701 6 HEATERTUBE QUARTZ F36PSE 220V FB-187709 4 HEATERTUBE QUARTZ F36 240V FB-187709 6 HEATERTUBE QUARTZ F36CHPS 240V FA-187707 4 HEATERTUBE QUARTZ F24 240V FA-187704 4 HEATERTUBE QUARTZ F24 208V FA-187704 6 HEATERTUBE QUARTZ F24PSE, F24TE 208V ZZ-187705 4 HEATERTUBE QUARTZ F24 220V 4 HA-115386 1 BLOCK TERMINAL, 9 POS. HB-115387 1 BLOCK TERMINAL, 8 POS 24”PS HC-115381 2 BLOCK TERMINAL, 4 POS. HM-115384 1 BLOCK TERMINAL, 5 POS 24”PS 5 FA-400660 1 SIDE PANEL, RIGHT SIDE 6 F5-53601 1 RACK 36” FB-100714 1 RACK, CHILLIES SPECIAL F36CHPS, F36PSE F5-52401 1 RACK 24” 7 2R-200715 4 LEG, 4” DIE CAST 8 2J-200427 1 PILOT LIGHT, DUALIT Power Saver Units 9 2J-200410 1 PILOT LIGHT F24, F36 (Before 2/2000) 10 2E-200566 1 SWITCH, RESET 11 HA-401780 1 GUARD, TOGGLE F24, F36 (Before 2/2000) 12 2R-200702 2 KNOB F24, F36 (Before 2/2000) 13 2R-200703 1 KNOB 24”PS, 36”PS 14 2J-200538 2 SWITCH, INFINITE 15 2E-200551 1 SWITCH, POWERSAVER 524SB, 536SB, F24PS, F36PS 16 2E-200543 1 SWITCH, ON/OFF F24, F36 (Before 2/2000) 17 2U-200560 1 MOTOR, FAN 18 FA-402599 1 SIDE PANEL, LEFT SIDE 19 2R-200562 1 GUARD, FAN 20 HG-402144 1 FAN SWITCH BRACKET 24”PS, 36”PS 21 2E-200574 1 SWITCH FAN CERAMIC 24”PS, 36”PS
Part
Number
Quantity
Per
Description
Fig
No.
NI 2P-115501 3 JUMPERS, 2 POS. SMALL NI 2P-115502 1 JUMPERS, 3 POS. SMALL NI 2K-200465 1 BUSHING, CORD HEYCO NI FA-140033 1 CORD SET 24”PS, 36”PS NI HX-140031 1 CORD SET F24F6 NI FA-140042 1 CORD SET F24W (wall mount) NI 2E-200387 1 CORD SET, FAN MOTOR
NI = NOT ILLUSTRATED, AR = AS REQUIRED
Part
Number
Quantity
Per
Description
Rev. 2/2/06
PAGE 8
OPERATORS MANUAL
HOLMAN CHEESE MELTERS
MODELS F24, F36, F40 & F24W, F36W, F40W
WIRING DIAGRAM
REV. 1/16/97 MJC
STAR MANUFACTURING
10 Sunnen Drive, St. Louis, MO 63143 U.S.A.
(800) 807-9054 (314) 781-2777
Parts & Service (800) 807-9054
www.star-mfg.com
Loading...