Star DWN3 Operators Manual

DRAWER
WARMERS
with thermostatic controls
MODEL
DW1, DWN1 DW2, DWN2 DW3, DWN3
Installation and
Instructions
2M-Z19504 Rev. B 10/20/15
Model DW1
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service.
Authorized Service Agent Listing
Model No.
Serial No.
Voltage
Purchase Date
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail customerservice@star-mfg.com
Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (314) 678-6303
Fax: (314) 781-2714
E-mail customerservice@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
TABLE OF CONTENTS
WARRANTY xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION 4 OPERATION 6 CLEANING INSTRUCTIONS 8 TROUBLESHOOTING SUGGESTIONS 9 MAINTENANCE INSTRUCTIONS 10 EXPLODRD VIEW & PARTS LIST 11 WIRING DIAGRAM 13 PARTS & SERVICE 17 CUSTOMER SERVICE DATA 17
SPECIFICATIONS
B
MODELS
DW1, DWN1
DW2, DWN2
DW3, DWN3
VOLTS
50/60 Hz 1ø
120 VAC 450 W 3.8 NEMA-5-15P
208/240 VAC 338/450 W 1.6/1.9 NEMA 6-15P
230
UK BS 1363A
120 VAC 900 W 7.5 NEMA-5-15P
208/240 VAC 676/900 W 3.3/3.8 NEMA 6-15P
230
UK BS 1363A
120 VAC 1350 W 11.3 NEMA-5-15P
208/240 VAC 1014/1350 W 4.9/5.6 NEMA 6-15P
230
UK BS 1363A
WATTS AMPS POWER CORD
450 W 1.9
900 W 3.9
1350 W 5.86
CEE-7/VII
CEE-7/VII
CEE-7/VII
Overall Dimensions
Model
DW1 10.875
DW3 41.125”
DWN1 10.875
DWN2 21”
DWN3 41.125”
Height “A”
w/o Legs
Width
“B”
29.25” 35.875” 21.5”DW2 21”
20.25” 35.875” 21.5”
Depth
Drawer
Open “C”
C D
Drawer
Closed “D”
p/n 2M-Z19504 Owners Manual DW, DWN Drawer Warmer Series
4”
A
3
POWER SUPPLY CORD
IL2942
POWER CORD
HUMITROL
RACK
(Optional)
DRAWER
INSERT PAN
AIR VENT CONTROL
TEMPERATURE CONTROL
ADJUSTABLE
LEG
HEATING INDICATOR
DRAWER
SLIDE
DRAWER SLIDE
DRAWER
STOP
DRAWER
ROLLER
DRAWER ROLLERS
HEATING
ELEMENT
ROLLER CATCH
DRAWER
CATCH
DRAWER
GASKET
IL2941
FEATURES & OPERATING CONTROLS
4
p/n 2M-Z19504 Owners Manual DW, DWN Drawer Warmer Series
CAUTION
WARNING
GENERAL INFORMATION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms.
Exposed surfaces can be hot to the touch and may cause burns.
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock.
INSTALLATION
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective
plastic lm, packing materials and accessories from the Appliance before
connecting electrical power or otherwise performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.
COMPONENTS
1 - 3 ea. DRAWERS (qty. depends on model) 1 - 3 ea. HUMITROL RACKS (if ordered with unit)
p/n 2M-Z19504 Owners Manual DW, DWN Drawer Warmer Series
5
INSTALLATION continued
IL2926
MOUNTS INTO
THREADED
HOLES IN
WARMER
FRAME
TURN BOTTOM
PORTION TO
ADJUST
GROUND
PIN
NEMA 5-15P
PLUG
NEMA 5-15R
RECEPTACLE
IL2927
IL2928
NEMA 6-15P
PLUG
GROUND
PIN
NEMA 6-15R
RECEPTACLE
Setup
Setup the appliance only on a rm, level, non-combustible
surface. Verify local codes for requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal over combustible material may not meet code for non-combustible surfaces.
Install adjustable legs or optional casters, one on each corner of the appliance, in the holes provided.
Verify that the unit sits rmly on ALL FOUR legs. With a spirit
level, check that the appliance is level front-to-back and side­to-side. With the adjustable legs, adjust as required to level the
appliance. All four legs must be adjusted to rmly contact the oor in order to prevent tipping.
If drawers were removed during installation, install drawer(s) in unit:
a. Check the roller catch inside the cabinet. The spring-loaded roller arm must be extended.
b. With the front of the drawer assembly tipped downward, engage the roller on the drawer with
the cabinet drawer slide.
c. Raise the drawer to the horizontal position until the drawer-mounted slide engages the dual
roller assembly on the cabinet.
d. Slide the drawer in until the catch engages. The drawer should remain tightly closed.
e. Slide the drawer out. The drawer stop should prevent the drawer from coming all of the way
out.
f. Install drawer insert pans.
WARNING
Avoid storing ammable or combustible materials in, on or near the appliance.
Electrical
Refer to electrical specications on page 3. Circuit must meet or exceed the amperage and
wattage requirements listed.
120 Volt units require a properly grounded NEMA 5-15R receptacle:
208/240 Volt units require a properly grounded NEMA 6-15R receptacle:
The ground prong of the power cord is part of a system designed to protect you from electric shock in the event of internal damage. DO NOT cut off the large round ground prong, or
twist a blade to t an existing receptacle.