These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change
without notice. While Star International Holdings Inc., Company exercises
good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information
provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance.
Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business8:00 am to 4:30 p.m. Central Standard Time
Hours:
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
SPECIFICATIONS
B
A
C
Superior Countertop Convection Ovens are
constructed of highly polished
stainless steel with high performance
heating elements and rear fans,
stainless steel door handle, chrome plated
wire racks and rack slides. The bake
chamber is made of stainless steel or
porcelain. The oven door is double pane
tempered glass and features a heavy-duty
hinge mechanism. Thermostat range is
175°F / 79°C to 500°F / 260°C. Timer
range is 0 to 120 minutes. Oven features a
heat indicator light and door interlock switch.
Oven holds either 3 or 4 standard size
baking sheets. Units available in various
voltages and is shipped with a NEMA
plug installed.
Model No. Voltage Wattage Amps NEMA Plug
CCOHS-3 120V 1,440 12 5-15
CCOQS-3 120V 1,440 12 5-15
OVEN FEATURE CCOQS-3 CCOHS-3
Number of Racks 3 3
Domestic Sheet Size 1/4 1/2
Inner Oven Chamber Stainless Steel Stainless Steel
Number of Motors/Fan(s) 1 1
Reversible Motors no no
Number of Interior Lights 0 1
Top Browning Element no yes
Steam Feature no no
Manual Reset Hi-Limit Protection yes yes
Door Interlock Switch yes yes
Timer
Single “Ding” yes yes
Electronic no no
3
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. FAILURE TO
GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING
NOTICE
NOTICE
NOTICE
CAUTION
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK
WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
The data plate is located on the lower right side panel of the unit. The oven voltage,
wattage, serial number, and clearance specications are on the data plate. This
information should be carefully read and understood before proceeding with the
installation.
The installation of this unit must conform to applicable national, state and locally
recognized installation standards.
The installation of any components such as a vent hood, grease extractors, re
extinguisher systems, must conform to their applicable National, State and locally
recognized installation standards.
MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES AND
CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES,
GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE
WARNING AND FOLLOW THE DIRECTIONS OF THE LABEL OF THE CLEANER TO BE
USED.
KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY OR HOSE
CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
WARNING
NOTICE
NOTICE
BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THE APPLIANCE WHEN
THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING
ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY.
Never use chlorine sanitizer in contact with stainless steel surfaces longer than 10
minutes. Longer contact can cause corrosion.
Service this, or any other Superior appliance must be performed by qualied
personnel only. Consult your authorized service station directory or call the factory
(at 1-800-807-9054), or log onto www.star-mfg.com for the service agent nearest you.
4
CAUTION
GENERAL INFORMATION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for
use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated
with the unit prior to putting it into operation. Make sure all people associated with its use
understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed.
This unit has been tested and carefully packaged to insure delivery of your unit in perfect
condition. If equipment is received in damaged condition, either apparent or concealed, a claim
must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked,
a request for inspection of concealed damage must be made with carrier within 15 days.
Be certain to retain all contents plus external and internal packaging materials for inspection.
The carrier will make an inspection and will supply necessary claim forms.
PURCHASER’S RESPONSIBILITY
It is the responsibility of the purchaser:
1. To see that the electric services for the oven are installed on site in accordance with
the manufacturer’s specications and in compliance with all local codes.
2. To unload, un-crate, and install the oven in its proper location and in accordance with
this installation operation manual.
CAUTION
3. To see that electric services are connected properly by a qualied installer of your
choice.
UN-CRATING
The oven will arrive completely assembled and ready to use. Prior to un-crating move the
oven as close to its nal location as practical. This will protect it from damage associated with
moving (scratches, dings, dropping).
These ovens weigh between 47 & 140 lbs. For safe handling, installer should obtain help as
needed, or employ appropriate materials handling equipment (such as a forklift, dolly, or pallet
jack) to remove the unit from the container and move it to the place of installation.
ANY STAND COUNTER OR OTHER DEVICE ON WHICH THE OVEN WILL BE LOCATED
MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE OVEN.
NEVER lay oven with the control side down, this will damage the controls.
5
WARNING
INSTALLATION
LOCATION
Do not install the Holman Counter top Convection Oven directly on the Floor.
Superior has stands available to accommodate your new oven.
CAUTION
DO NOT install oven closer than 1" on the control side, from another oven.
DO NOT install oven closer than 12" on the control side, from a uncontrolled heat source
(char broiler, open ame, griddle, etc.), unless a Hi-Temperature Spacer is installed then
it can be reduced to 1".
ELECTRICAL
The ovens are equipped for the voltage indicated on the nameplate mounted on the
lower right side panel of the oven. They will operate on alternating current (AC) only.
A cord & plug is provided installed.
All electrical connections must be made by a licensed electrician and in accordance with local
codes or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CSA
STD. C22.1)
DO NOT CONNECT TO DIRECT CURRENT (DC).
DO NOT CONNECT TO ANY OTHER TYPE OF CURRENT THAT IS OTHERWISE SPECIFIED
FOR THIS SPECIFIC UNIT, OR MACHINE WILL BE SERIOUSLY DAMAGED.
AIR SUPPLY
Make certain not to obstruct the ow of combustion (gas) and ventilation air. Provisions for
adequate air supply must be furnished.
LEVELING THE UNIT
This Superior Oven comes with legs installed at the factory, proper leveling is essential to receive
a proper baking performance. Level unit by adjusting the (4) feet which have an adjustment
of 1-3/4” (43.75mm) for accurate leveling.
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.