These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change
without notice. While Star International Holdings Inc., Company exercises
good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information
provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance.
Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business
8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 264-7827 Local (314) 781-2777
Fax:(800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent Listing
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
Page 3
CAUTION
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for use
directly by the general public in food service locations. For equipment to be used by the general
public, please contact the factory.
This gas appliance is equipped for the types of gas indicated on the nameplate mounted on the
front panel. It is shipped adjusted for use on natural gas.
The installation of the Appliance should conform to the NATIONAL FUEL GAS
CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY
RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing the equipment.
CAUTION
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE APPLIANCE AREA
CLEAR AND FREE FROM COMBUSTIBLES.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in excess
of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend
a qualied installing agency install this appliance. They should be familiar with gas installations and
your local gas requirements. In any case, your gas company should be called to approve the nal
installation. In addition, there should be posted, in a prominent location, detailed instructions to be
followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.
LEVELING UNIT
Units are shipped with feet detached. To attach feet, remove the grates, lay unit on it's side and
screw feet into sockets on bottom. Level unit by adjusting the (4) feet which have an adjustment of
1-3/4" for accurate and perfect line-up with other Star-Max series units.
DO NOT REMOVE FEET.
GAS PIPING
Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas
sufcient to meet the full gas input of the appliance. If the appliance is to be connected to existing
piping, it shall be checked to determine if it has adequate capacity. Joint compound (pipe dope)
shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be
resistant to the action of L.P. gases.
WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on the
appliance will damage the automatic valve and affect its operation. When installing this appliance,
all pipe and ttings must be free from all internal loose dirt.
3
Page 4
CLEARANCE
Minimum wall clearances for the sides and back of the models contained in this manual shall
be as follows:
Combustible Non-Combustible
Wall Wall
Hotplates 9" 0"
Stock Pot Range 14" 0"
PRESSURE REGULATOR
A convertible pressure regulator set at 6" water column for use on natural gas is furnished.
(For LP models the regulator is set for 10" water column pressure.) Attach the regulator to the
supply pipe, located at the back of the unit, make sure gas ow arrow on regulator is pointing
towards manifold. The gas supply is then connected to the regulator. A 1/8" tap is furnished on
the manifold for checking pressure. The manifold is accessible by removing the front panel.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the unit and within six feet of the
appliance, and is not provided.
CONNECTING GAS SUPPLY LINE
The gas inlet on this appliance is sealed at the factory to prevent entry of dirt. Do not remove
this seal until the actual connection is made to the gas supply line.
CHECKING FOR GAS LEAKS
Soap and water solution or other material acceptable for the purpose, shall be used in locating
gas leakage. Matches, candle ame or other sources of ignition shall not be used for this
purpose.
AIR SUPPLY
Provisions for adequate air supply must be furnished.
AIR INTAKES IN BOTTOM
Make certain the air intake openings in the bottom of the appliance are not obstructed. They
are essential for proper combustion and operation of the appliance.
EXHAUST CANOPY
It is essential that facilities be provided to carry off fumes and gases.
GAS INPUT OF OPEN TOP RANGES
For Natural Gas: All models except 601SPRD-22,000 BTU/HR for each burner. Model
601SPRD-55,000 BTU/HR for each burner. Regulator output pressure set at 6" water column.
For Propane Gas: All models except 601SPRD-22,000 BTU/HR for each burner.
Model 601SPRD-45,000 BTU/HR for each burner. Regulator output pressure set at
10" water column.
Note: The appliance is equipped with orice hoods that is stated on the units
nameplate. For natural units a separate set of hoods will be provided for use on
propane gas. The propane hoods are located on the front panel. Factory set LP
models do not include the natural gas hoods.
4
Page 5
LIGHTING INSTRUCTIONS
The appliance is equipped with standing pilots; each pilot is located in front of the burner on
Models 602HD, 602HWD, 602HDS and 606HD. On Models 602HD-SU, 604HD-SU and 606HDSU the pilots for the front burners are located in front of the burners, on the rear burners pilots
are located on the side of the burners. On Model 601SPRD, the pilots are located on the right
side of each burner. Pilots should be lighted immediately after the gas is turned on by the
manual shutoff valve.
1. Turn control knobs to "OFF" position.
2. Light pilot with a lighted taper.
3. The pilot valves are located on the manifold installed at the front of the unit behind the front
panel. For access to the valves, remove the front panel, which is attached to the frame
with 4 sheet metal screws. Turn the adjustment screws on the front of the pilot valves. The
pilots should be adjusted to a nice, blue short ame (1/4" high) to have good ignition to the
burners.
If the pilot(s) is out turn off gas, wait 5 minutes and repeat steps (1) through (3).
4.
5. Install the front panel to the front of the frame.
ADJUSTING BURNERS
Remove front panel in order to gain access to the primary air shutters. With control valve for the
front burner turned to full "ON" position, close the air shutters to give a soft blue ame having
luminous tips and open to a point where the yellow tips disappear, then tighten the locking
screws. Repeat this procedure with the rear burner.
ADJUSTING UNIT FOR USE ON PROPANE GAS
Units are shipped with orices and pressure regulator for operation with natural gas (6" water
column). To convert unit from natural to propane gas follow these instructions (Note: LP models
are factory set for propane gas and do not require a conversion. these can be converted to
natural gas using the natural gas orices and converting the regulator to natural gas):
1. Set regulator outlet pressure to 10" water column. A 1/8" pipe plug on the manifold can be
removed for attaching a pressure gauge. Remove the slotted cover from the pressure
regulator and invert the plug. Replace the cover on the regulator and plug on the manifold.
Regulator is now set at
2. Remove natural gas orices, #46 for all models except 601SPRD, #.125 for 601SPRD, and
install propane orices, painted black, (#54 for all models except 601SPRD, #45 for 601SPRD)
located in a bag on the outside of the front panel. In order to remove natural gas orices:
a.
Remove grates and burners.
b. Remove orices from the manual valves and from ttings on extended gas pipes,
replace with the propane orices.
c.
Install burners and grates.
10" W.C.
OPERATING PROCEDURE
Each burner will deliver up to 22,000 BTU/HR of heat on all models except 601SPRD (on
601SPRD each burner is rated 55,000 BTU/HR for natural gas and 45,000 BTU/HR for propane)
and is controlled by a manual On/Off valve. The right control knob controls the front burner and
the left control knob controls the rear burner on all models except 601SPRD. On the 601SPRD,
the right control knob controls the inner burner and the left control knob controls the outer burner.
After the pilot is once lit and adjusted, the burners will ignite automatically by turning the control
knob to any position between On and Off.CLEANING THE EXTERIOR (Stainless Steel Only)
The exterior surface can be kept clean and attractive by regularly wiping it with a clean soft cloth.
Any discoloration can be removed with a non-abrasive cleaner. The burner grates and trough tray
can be removed for cleaning.
MAINTENANCE AND REPAIRS
Contact the factory or one of its representatives or a local service company for service or
maintenance if required.
5
Page 6
Part# 2M-4497-2 05/06 RB
The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty.
FOR ASSISTANCE
Should you need any assistance regarding the Operation or Maintenance of any Star equipment; write, phone, fax or email our Service Department.
In all correspondence mention the Model number and the Serial number of your unit, and the voltage or type of gas you are using.
This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in
which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the
transportation company who delivered the item to you and initiate your claim with same. If this procedure is not followed, it may affect the warranty
status of the unit.
LIMITED EQUIPMENT WARRANTY
All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is
limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited
to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies. Models that are considered portable (see below)
should be taken to the closest Star service agency, transportation prepaid.
> Star will not assume any responsibility for loss of revenue.
> On all shipments outside the United States and Canada, see International Warranty.
* The warranty period for the JetStar six (6) ounce & Super JetStar eight (8) ounce series popcorn machines is two (2) years.
* The warranty period for the Chrome-Max Griddles is five (5) years on the griddle surface. See detailed warranty provided with unit.
* The warranty period for Teflon/Dura-Tec coatings is one year under normal use and reasonable care. This warranty does not apply if damage occurs to
Teflon/Dura-Tec coatings from improper cleaning, maintenance, use of metallic utensils, or abrasive cleaners. This warranty does not apply to the
“non-stick” properties of such materials.
> This warranty does not apply to "Special Products" but to regular catalog items only. Star's warranty on "Special Products" is six (6) months on parts
and ninety (90) days on labor.
> This warranty does not apply to any item that is disassembled or tampered with for any purpose other than repair by a Star Authorized Service Center or
the Service Center's sub-agency.
> This warranty does not apply if damage occurs from improper installation, misuse, wrong voltage, wrong gas or operated contrary to the Installation and
Operating instructions.
> This warranty is not valid on Conveyor Ovens unless a "start-up/check-out" has been performed by a Factory Authorized Technician.
PARTS WARRANTY
Parts that are sold to repair out of warranty equipment are warranted for ninety (90) days. The part only is warranted. Labor to replace the part is
chargeable to the customer.
SERVICES NOT COVERED BY WARRANTY
PORTABLE EQUIPMENT
Star will not honor service bills that include travel time and mileage charges for servicing any products considered "Portable" including items listed below.
These products should be taken to the Service Agency for repair:
1. Travel time and mileage rendered beyond the 50 mile radius limit
2. Mileage and travel time on portable equipment (see below)
3. Labor to replace such items that can be replaced easily during a daily cleaning
routine, ie; removable kettles on fryers, knobs, grease drawers on griddles, etc.
4. Installation of equipment
5. Damages due to improper installation
6. Damages from abuse or misuse
7. Operated contrary to the Operating and Installation Instructions
8. Cleaning of equipment
9. Seasoning of griddle plates
10. Voltage conversions
11. Gas conversions
12. Pilot light adjustment
13. Miscellaneous adjustments
14. Thermostat calibration and by-pass adjustment
15. Resetting of circuit breakers or safety controls or reset buttons
16. Replacement of bulbs
17. Replacement of fuses
18. Repair of damage created during transit, delivery, &
installation OR created by acts of God
* The Model 510FD Fryer.
* The Model J4R, 4 oz. Popcorn Machine.
* The Model 518CMA & 526CMA Cheese Melter.
* The Model 12MC & 15MC & 18MCP Hot Food Merchandisers.
* The Model 12NCPW & 15NCPW Nacho Chip/Popcorn Warmer.
* All Hot Dog Equipment except Roller Grills & Drawer Bun Warmers.
* All Nacho Cheese Warmers except Model 11WLA Series Nacho Cheese Warmer.
* All Condiment Dispensers except the Model HPDE, & SPDE Series Dispenser.
* All Specialty Food Warmers except Model 130R, 11RW Series, and 11WSA Series.
* All QCS/RCS Series Toasters except Model QCS3 & RCS3 Series.
6
Page 7
1
2
3
24
4
5
7
9
10
12
13
14
16
17
18
19
20
21
8
9
8
22
6
15
NAMEPLATE
11
GAS HOTPLATE
MODEL 602-, 604-, 606-
STAR MANUFACTURING INTERNATIONAL, INC.
SK1527 REV. D6/17/10
7
Page 8
1
2
3
4
5
7
9
10
12
13
1416
17
18
19
20
21
8
9
8
22
6
15
24
NAMEPLATE
23
11
STAR MANUFACTURING INTERNATIONAL, INC.
SK1528 REV. D
6/16/10
GAS HOTPLATE STEP-UP DESIGN
MODEL 602HD-SU, 604HD-SU, 606HD-SU
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
11
Page 12
12
5
pour la maintenance et les réparations nécessaires.
Contactez l’usine ou l’un de ses représentants, ou bien encore une société de services locale
MAINTENANCE ET RÉPARATIONS
l’égouttoir peuvent être retirés pour être nettoyés.
peuvent être nettoyées à l’aide d’un agent nettoyant non abrasif. Les grilles des brûleurs et
La surface externe peut être nettoyée en utilisant un linge propre et doux. Les décolorations
(Acier inoxydable seulement)
NETTOYAGE DE L’EXTÉRIEUR
automatiquement lorsque vous placerez simplement le bouton entre On et Off.
l’extérieur. Après que les veilleuses aient été allumées et réglées, les brûleurs s’allumeront
droit contrôle le brûleur situé vers l’intérieur et le bouton gauche contrôle le brûleur situé vers
arrière sur tous les modèles à l’exception du Modèl 601SPRD. Sur ce dernier modèle, le bouton
manuel On/Off. Le bouton droit contrôle le brûleur avant et le bouton gauche contrôle le brûleur
le gaz naturel et 45,000 BTU/heure pour le propane). Les brûleurs sont contrôlés par un bouton
du Modèl 601SPRD (sur ce modèle, les brûleurs fourniront 55,000 BTU/heure de chaleur pour
Chaque brûleur fournira jusqu’à 22,000 BTU/heure de chaleur sur tous les modèles à l’exception
PROCÉDURE DE FONCTIONNEMENT
Réinstallez les brûleurs et les grilles.
c.
les avec les orices à propane.
b. Retirez les orices des robinets manuels et des raccords sur les tuyaux à gaz et remplacez-
Retirez les grilles et les brûleurs.
a.
gaz naturel :
45), situés dans l’étui placé à l’extérieur du panneau avant. Pour retirer les orices pour le
(no. 54 pour tous les modèles à l’exception du Modèl 601SPRD qui utilise les orices no.
(no .125 pour le Modèl 601SPRD), et installez les orices pour le propane, peints en noir
Retirez les orices no. 46 pour le gaz naturel sur tous les modèles, sauf le modèl 601SPRD
2.
de colonne d’eau (10 pouces).
sur le régulateur et branchez sur le conduit. Le régulateur est maintenant réglé à .254 mm
le couvercle rainuré du régulateur de pression et insérez-y la prise. Replacez le couvercle
de 1/8 de pouce sur le conduit peut être retiré pour y connecter une jauge de pression. Retirez
1. Réglez la pression de sortie du régulateur à 254 mm de colonne d’eau (10 pouces). Un tuyau
les orices de gaz naturel et convertissant le régulateur en gaz naturel):
propane et n'exigent une conversion. Ceux-ci peuvent être convertis en gaz naturel en utilisant
suivez les instructions ci-dessous (Note: Les modèles de LP sont usine préréglé pour le gaz de
au gaz naturel (à 152 mm de colonne d’eau - 6 pouces). Pour convertir l’unité au propane,
Les unités sont envoyées avec les couvercles d’orices et le régulateur pour une utilisation
RÉGLAGE DE L’UNITÉ POUR L’UTILISATION AU PROPANE
arrière.
ne soit pas jaune. Serrez ensuite les vis de serrage. Reprenez cette procédure pour le brûleur
d’obtenir une amme bleue dont les extrémités sont lumineuses et de façon à ce que la amme
le robinet de contrôle du brûleur frontal est en position “ON”, fermez les obturateurs d’air an
Retirez le panneau frontal an de pouvoir accéder aux obturateurs d’air principaux. Lorsque
RÉGLAGE DES BRÛLEURS
Page 13
13
4
5. Installez le panneau frontal sur l’avant du cadre.
(1) à (3).
4.
Si une ou des veilleuses sont éteintes, fermez le gaz, attendez 5 minutes et reprenez les étapes
de pouce de haut) pour obtenir un bon allumage les brûleurs.
Les veilleuses devront être réglées de façon à ce que la amme soit bleue et courte (un quart
vis le retenant au cadre. Tournez les vis de réglage situées à l’avant des robinets des veilleuses.
panneau frontal. Pour accéder aux robinets, retirez le panneau frontal en dévissant les quatre (4)
3. Les robinets des veilleuses sont situés sur le conduit installé à l’avant de l’unité, derrière le
2. Allumez les veilleuses à l’aide d’un briquet.
1. Placez les boutons en position “OFF”.
est ouvert au moyen du robinet d’arrêt manuel.
situées sur le côté droit de chaque brûleur. Les veilleuses devraient être allumées dès que le gaz
les brûleurs avant et sur les côtés des brûleurs arrières. Sur le Modèl 601SPRD, les veilleuses sont
Modèles 602HD-SU, 604HD-SU et 606HD-SU, les veilleuses sont situées devant les brûleurs pour
situées devant chaque brûleur sur les Modèles 602HD, 602HWD, 602HDS et 606HD. Sur les
L’appareil est équipé de veilleuses d’allumage qui brûlent en permanence . Ces veilleuses sont
INSTRUCTIONS POUR L’ALLUMAGE
gaz naturel.
sont situés sur le panneau frontal. Les usine réglés modèles de LP n'incluent pas les capots de
de couvercles est fourni pour utiliser l’appareil avec du propane. Les couvercles pour le propane
Remarque : L’appareil est équipé de couvercles d’orices pour le gaz naturel. Un autre ensemble
régulateur est à 254 mm de colonne d’eau (10 pouces).
1SPRD: 45,000 BTU/H pour chacun des brûleurs. La pression de sortie du
des brûleurs. Modèl 60
Pour le propane: Tous les modèles à l’exception du Modèl 601SPRD: 22,000 BTU/H pour chacun
sortie du régulateur est à 152 mm de colonne d’eau (6 pouces).
chacun des brûleurs. Modèl 601SPRD: 55,000 BTU/H pour chacun des brûleurs. La pression de
Pour le gaz naturel: Tous les modèles à l’exception du Modèl 601SPRD: 22,000 BTU/H pour
ENTRÉE DE GAZ DES CUISINIÈRES À GAZ À PLAQUE OUVERTE
Il est primordial que des installations soient prévues pour l’évacuation des gaz et fumées.
HOTTE ASPIRANTE
l’appareil.
Elles sont primordiales pour une combustion adéquate et un bon fonctionnement de
Assurez-vous que les ouvertures situées en dessous de l’unité ne sont pas obstruées.
OUVERTURES EN DESSOUS DE L’UNITÉ
Vous devrez prévoir une alimentation en air adéquate.
ALIMENTATION D’AIR
devraient en aucun cas être utilisées dans ce but.
pour localiser les fuites de gaz. Des allumettes, des bougies ou autres sources d’ignition ne
Il est possible d’utiliser une solution à base d’eau et de savon ou tout autre matériau acceptable
RECHERCHE DE FUITES DE GAZ
à la canalisation d’alimentation de gaz.
dans l’unité. Gardez la protection en place jusqu’à ce que vous soyez prêt à effectuer la connexion
L’entrée de gaz pour cet appareil est scellée à l’usine pour éviter que des saletés ne pénètrent
CONNEXION DE LA CANALISATION D’ALIMENTATION DE GAZ
l’appareil. Ce robinet n’est pas fourni.
Un robinet d’arrêt manuel devrait être installé en amont de l’unité, à environ 183 cm (6 pieds) de
ROBINET D’ARRÊT MANUEL
Page 14
3
14
au conduit de distribution en retirant le panneau frontal.
pouce est installé sur le conduit de distribution pour vérier la pression. Il est possible d’accéder
distribution. L’alimentation de gaz doit ensuite être connectée au régulateur. Un robinet de 1/8 de
de l’unité et assurez-vous que la èche du ux de gaz sur le régulateur pointe vers le conduit de
pour 10" pression de eau colonne.) Reliez le régulateur au tuyau d’alimentation situé à l’arrière
utilisé avec du gaz naturel est fourni avec l’appareil. (Pour le LP modèle le régulateur est placé
Un régulateur de pression convertible réglé à 152 mm de colonne d’eau (6 pouces) pour être
Minimum distances aux mur pour les côtés et le dos des modèles contenus en ce manuel seront
DÉGAGEMENT
vous qu’ils sont exempts de toute saleté à l’intérieur.
fonctionnement. Lorsque vous installez cet appareil, ainsi que les tuyaux et raccords, assurez-
canalisations de gaz de l’appareil endommageront le robinet automatique et affecteront son
gaz basse pression. AVERTISSEMENT : Toutes les saletés ou particules de métal dans les
le letage extérieur des tuyaux. Les pâtes utilisées devraient être résistantes à l’action des
est adéquate. La pâte lubriante ne devrait être utilisée qu’avec parcimonie et seulement sur
à des canalisations déjà existantes, elles devraient être vériées pour déterminer si leur capacité
façon à fournir une alimentation en gaz sufsante pour l’appareil. Si l’appareil doit être connecté
Les canalisations de gaz devraient être neuves, propres, de taille adéquate et être installées de
CANALISATIONS DE GAZ
NE PAS RETIRER LES PIEDS.
MISE EN GARDE
Max.
pouce) pour que l’unité soit parfaitement alignée et de niveau avec les autres unités séries StarMettez l’unité à niveau en réglant les quatre (4) pieds qui doivent être réglés à 4.45 cm (1.75
couchez l’appareil sur le côté et vissez les pieds dans les logements situés sous l’appareil.
Les unités sont envoyées avec les pieds détachés. Pour installer les pieds, retirez les grilles,
MISE À NIVEAU DE L’APPAREIL
votre fournisseur local de gaz.
être afchées bien en vue à proximité de l’unité. Vous pouvez obtenir ces ins-tructions auprès de
indiquant la marche à suivre dans le cas où l’opérateur détecterait une odeur de gaz devraient
locale de gaz devrait venir approuver l’installation nale. De plus, des instructions détaillées
ainsi que les exigences locales concernant le gaz. Dans tous les cas de gure, la compagnie
installe votre appareil. Le personnel de cette agence devrait connaître les installations à gaz
inférieures à 0.5 PSIG. Pour votre protection, nous recommandons qu’une agence spécialisée
de pression du système d’alimentation de gaz lorsque les pressions d’essai sont égales ou
être coupés de l’alimentation de gaz en fermant le robinet d’arrêt manuel pendant les essais
pressions d’essai sont supérieures à 0.5 PSIG. Cet appareil et le régulateur de pression doivent
du système d’alimentation de gaz pendant les essais de pression du système lorsque les
Cet appareil, le régulateur de pression et le robinet d’arrêt individuel doivent être déconnectés
L’APPAREIL.
HORS DU VOISINAGE DE
TENIR TOUT COMBUSTIBLE
ESURE DE SÉCURITÉ
AUTRE APPAREIL.
LIQUIDES INFLAMMABLES À PROXIMTÉ DE CET APPAREIL OU DE TOUT
NE PAS ENTREPOSER NI UTILISER DE’ESSENCE NI AUTRES VAPEURS OU
Page 15
2
15
de procéder à son installation ou entretien.
Lire attentivement les instructions d'installation, de fonctionnement et d'entretien avant
incorrect de cet appareil peut causer des dommages matérials, des blessures ou la mort.
AVERTISSEMENT: L'installation, le réglage, la modication, la réparation ou l'entretien
PROPANE CAN/CGA-B149.2, AINSI QU’AUX CODES LOCAUX, LE CAS ÉCHÉANT.
AU GAZ NATUREL ACTUEL CAN/CGA-B149.1 OU AU CODE D’INSTALLATION AU
L’INSTALLATION AU CANADA DEVRAIT ÊTRE CONFORME AU CODE D’INSTALLATION
ET RÉGLEMENTATIONS DE LA COMPAGNIE DE GAZ LOCALE.
COMBUSTIBLE “ANSI Z223.1 - DERNIÈRE ÉDITION”, AINSI QU’À TOUTES LES RÈGLES
L’installation de l’appareil devrait être conforme au CODE NATIONAL DU GAZ
l’appareil. Il est envoyé réglé pour une utilisation au gaz naturel.
Cet appareil à gaz est équipé pour les types de gaz indiqués sur la plaque signalétique à l’avant de
pouvant être utilisé par le public général, prière de contacter l’usine.
être utilisé à la maison ou par le public général dans les lieux de restauration. Pour tout équipement
par un personnel formé et expérimenté à son fonctionnement. Cet équipement n’est pas vendu pour
Cet équipement est conçu et vendu pour une utilisation commerciale seulement, et pour être utilisé
MISE EN GARDE
NOTIFICATION
NOTIFICATION
RÉFÉRENCE
DONNÉES GÉNÉRALES D’INSTALLATION
Veuillez avoir votre numéro et numéro de série de type pour un service plus rapide.
disponible pendant des heures de travail normales pour répondre à toutes les questions qui peuvent se poser.
à la liste autorisée de centre commercial équipée d'unité. Le service SVP de service de Star (1-800-807-9054)
Entrez en contact avec votre agent autorisé local de service pour le service ou l'entretien requis. Référez-vous
ENTRETIEN ET RÉPARATIONS
précédemment acheté.
aux remplacements correspondants pour l’équipement
aux changements, aux améliorations, aux additions ou
préalable. De telles révisions ne ont pas droit l’acheteur
et la conception de produits sans communication
Star se réserve le droit de changer des caractéristiques
de toute la responsabilité.
fournies par usine véritable de Star soulage le fabricant
Employer n’importe quelle partie autre que les pièces
MAINTENEZ CE MANUEL POUR LA FUTURE
du manuel accompagnant l’appareil.
des instructions importantes de fonctionnement et d’entretien
Ce symbole est prévu pour alerter l’utilisateur à la présence
SYMBOLE DE SÛRETÉ
Page 16
16
606HD-SU
2M-Z6103 Rev. D 7/23/10
et d’opération
d’installation
Instructions
601SPRD
MODÈLES
606HD, 606HD-SU
604HD, 604HD-SU
602HDS, 602HWD, 602HD, 602HD-SU
CHAUFFANTES AU GAS
PLAQUES
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.