Star 5136CD-230V Operators Manual

®
®
®®®
ELECTRIC COUNTER
CHAR-BROILER
MODEL
Installation and
Operation
Instructions
2M-Z9838 Rev. A 8/7/06
5136CD
1
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster
service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
2
SPECIFICATIONS
5136CD Type: Innite Control, 3 Controls, 8.3/9.1 KW, 594 sq. in (3832 sq. cm) Grid Area Weight: Installed - 175 lb (80 kg); Shipping - 215 lb. (98 kg) Dimensions: 36" W x 25 5/8" D x 14 1/4"H (91 cm W x 65 cm D x 36 cm H) Volts: 220V
, 3 PH Amps: x - 12.6 y - 12.6 z - 12.6 n - 12.6
230V, 3 PH Amps: x - 13.2 y - 13.2 z - 13.2 n - 13.2
GENERAL INSTALLATION INSTRUCTIONS
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms.
These Electric Char-broilers are equipped for the voltage and wattage indicated on the nameplate mounted on the front panel. These units are designed to operate on alternating current (AC)
only.
DO NOT CONNECT TO DIRECT CURRENT (DC).
WARNING DO NOT CONNECT TO AN ELECTRICAL SYSTEM OPERATING AT MORE THAN 240 VOLTS TO GROUND.