Star 502FD Parts List

®
®
®®®
ELECTRIC HOT PLATE
MODELS
501FD, 502D, 502FD, 502DS
Operation
Instructions
2M-Z6062 Rev. A 10/14/113
502D
502FD
1
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (314) 678-6303
Fax: (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent Listing
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
CAUTION
Specications
Electrical Specications Dimensions
Model Voltage kW Width Depth Height
501FD 208/240 1.95/2.6
501FD-208V 208V 2.6
502D
502DS
502FD 3.9/5.2
208/240
3.1/4.2
12” (30.4cm)
12” (30.5cm) 28 (71.1cm)
17.25”
(43.8cm)
10.7”
(27.2cm)
11 5/8”
(29.5cm)
GENERAL OPERATING INSTRUCTIONS
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
The Star-Max Electric Hot Plates are equipped for the voltage indicated on the nameplate mounted on the front panel. This unit is designed to operate on alternating current (A.C.), two wire single phase service only.
DO NOT CONNECT TO DIRECT CURRENT (D.C.).
Total Connected Load:
502FD: at 240 Volts, Wattage is 5,200. at 208 Volts, Wattage is 3,900.
502D/502DS: at 240 Volts, Wattage is 4,200. at 208 Volts, Wattage is 3,150.
CAUTION
CAUTION
INSTALLATION
For your protection, we recommend that a qualied electrician install this appliance. The electrician
should be familiar with electrical installations and your local electrical requirements. The external
wiring should be in conduit or an approved type of exible cable and of suitable size to carry the load.
The supply circuit should be properly fused and equipped with a means of disconnecting as required by local electrical code. The body of the hot plate should be grounded (Do not ground to a gas supply pipe). The connections are made in this unit at the pigtail leads located in the junction box on the back of the unit. To gain access to the pigtail leads remove cover on junction box.
LOCATE THE UNIT
Do not install the unit closer than 1 inch from a side wall and/or closer than 1 inch from a rear wall.
LEVELING UNIT
Level unit by adjusting the (4) feet for accurate and perfect line up with other Star-Max series units.
DO NOT INSTALL WITHOUT FEET.
USE ONLY FLAT BOTTOM PANS AND POTS! DO NOT USE RAISED BOTTOM UTENSILS OR BUCKETS! GOOD HEAT TRANSFER DEPENDS UPON GOOD CONTACT BETWEEN THE ELEMENT AND POT.
NOTE: Using a 12” diameter or larger pan/pot may cause damage to the element or internal wiring. Such damages are not covered by warranty.
Two (2) heating elements are used. For the 502FD each element draws 2,600 Watts on 240 Volts and 1,950 Watts on 208 Volts. For the 502D and DS each element draws 2,100 Watts on 240 Volts and
1,575 Watts on 208 Volts. Each element is controlled by an innite position switch. The right control
knob controls the rear cooking element and the left control knob controls the front cooking element. On “HI” the element delivers uninterrupted full heat. Between “LO” and “5” any desired amount of heat can be obtained between 6% and 60% of full heat.
Signal lights are provided above the control knobs to give a visual check if either one or both heating units are turned on.
3