Star 502 Parts List

Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143
Phone: (314) 781-2777 FAX: (314) 781-3636
STAR-MAX
ELECTRIC HOT PLATE
MODELS
502 AND 502F
and Operating Instructions
2M-Y7466 Rev. B 7/18/95
Model 502F
1
INSTALLATION AND OPERATING INSTRUCTIONS
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
LEVELING UNIT
Level unit by adjusting the (4) feet for accurate and perfect line up with other Star-Max series units.
CAUTION
DO NOT INSTALL WITHOUT FEET.
OPERATING PROCEDURE
The Star-Max models 502 and 502F Electric Hot Plates are equipped for the voltage indicated on the nameplate mounted on the front panel. This unit is designed to operate on alternating current (A.C.), two wire single phase service only. DO
NOT CONNECT TO DIRECT CURRENT (D.C.).
Total Connected Load
502F - at 240 Volts, Wattage is 5200. at 208 Volts, Wattage is 3900.
502 - at 240 Volts, Wattage is 4200. at 208 Volts, Wattage is 3150.
INSTALLATION
For your protection, we recommend that a qualified electrician install this appliance. The electrician should be familiar with electrical installations and your local electrical requirements. The external wiring should be in conduit or an approved type of flexible cable and of suitable size to carry the load. The supply circuit should be properly fused and equipped with a means of disconnecting as required by local electrical code. The body of the hot plate should be grounded (Do not ground to a gas supply pipe). The connections are made in this unit at the pigtail leads located in the junction box on the back of the unit. To gain access to the pigtail leads remove cover on junction box.
CAUTION
USE ONLY FLAT BOTTOM PANS AND POTS! DO NOT USE RAISED BOTTOM UTENSILS OR BUCKETS! GOOD HEAT TRANSFER DEPENDS UPON GOOD CONTACT BETWEEN THE ELEMENT AND POT.
Two (2) heating elements are used. For the 502F each element draws 2600 watts on 240 Volts and 1950 watts on 208 Volts. For the 502 each element draws 2100 watts on 240 Volts and 1575 watts on 208 Volts. Each element is controlled by an infinite position switch. The right control knob controls the rear cooking element and the left control knob controls the front cooking element. On "HI" the element delivers uninterrupted full heat. Between "LO" and "5" any desired amount of heat can be obtained between 6% and 60% of full heat.
Signal lights are provided above the control knobs to give a visual check if either one or both heating units are turned on.
2
CLEANING
The exterior surfaces can be kept clean and attractive by regularly wiping with a clean soft cloth. Any discoloration can be removed with a non-abrasive cleaner.
For model 502, the heating elements may be raised for access to the drip pans, which may be removed for cleaning and the bottom pan may be removed by sliding pan forward.
REPLACEMENT OF INFINITE CONTROL
BE SURE POWER IS DISCONNECTED BEFORE ATTEMPTING TO SERVICE UNIT.
1) Pull control knobs on front panel forward to remove.
2) Remove 4 screws from front panel and tilt front panel forwards.
3) Remove the nut that mounts the inoperative control and pull the control to the side.
4) Remove one wire at a time from the inoperative control and connect at the same terminal on the new control. Carefully check to see that proper wires have been connected to the terminals of the control. See attached wiring diagram.
5) Assemble new control to the front panel.
MAINTENANCE AND REPAIRS
Contact the factory or one of its representatives or a local service company for service or maintenance if required.
RETAIN THIS MANUAL FOR FUTURE REFERENCE Part No. 2M-Y7466 Rev. B 7/18/95