Star 255B Operators Manual

Star
Manufacturing
International Inc.
St. Louis, MO 63143
Phone: (800) 264-7827
FAX: (800) 264-6666
DESIGNER SERIES
GAS CHARBROILER
MODELS 255B and 257
Installation
and
Operating
Instructions
2M-Y3213 Rev. G 10/2/95
Model 255B
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
This Star Designer Series Gas Broiler is equipped for the type of gas indicated on the nameplate mounted on the inside of the door.
-IMPORTANT-
INSTALLATION: INSTALL IN NON­COMBUSTIBLE LOCATIONS ONLY! Clearance from non-combustible construction must be 6" from back and sides.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend a qualified installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the final installation. In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.
LEVELING UNIT
This broiler is supplied with 4 feet which must be screwed into the legs attached to the body. Level unit by adjusting the 4 feet which must have an adjustment of 1" for accurate and perfect line-up with other Designer Series Units.
The installation of the appliance must conform with the local codes, NATIONAL FUEL GAS CODES "ANSI Z223.1 ­LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE. KEEP THE
APPLIANCE AREA CLEAR AND FREE
FROM COMBUSTIBLES.
CAUTION
DO NOT INSTALL WITHOUT ATTACHING THE FEET - DO NOT REMOVE FEET.
GAS INPUT TO BROILER
90,000 BTU/HR total, or 15,000 BTU/ HR for one burner for Model 257. 60,000 BTU/HR total, or 15,000 BTU/HR for one burner for Model 255B.
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound (pipe dope) shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on the appliance will damage the automatic valve and affect its operation. When installing this appliance, all pipe and fittings must be free from all internal loose dirt.
PRESSURE REGULATOR
A convertible pressure regulator is provided with each broiler. It should be connected to the inlet pipe at the rear of the unit. The gas supply line is then connected to it. It is shipped set for 6" W.C. manifold pressure for use on natural gas. Allow 6" clearance from back of unit to wall for servicing and installation.
CONNECTING GAS SUPPLY LINE
The gas inlet of the broiler is sealed at the factory to prevent entry of dirt. Do not remove this seal until actual connection is made to the gas supply line.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the broiler.
NATURAL/LP GAS
This broiler is equipped with fixed orifice hoods and is shipped from the factory for use on Natural Gas. To convert to LP gas, install the black burner orifice hoods
supplied in cloth bag attached on or near the front panel (See directions below). "For natural gas when equipped with no.
52 drill size orifice."
"For LP gas when equipped with no. 56
drill size orifice." "For your safety refer to installation instructions for conversion procedure."
1.Remove grill, radiants and burners.
2.Remove the burner orifice hoods and
install the black orifice hoods supplied.
3.Replace the burners, radiants and grill.
4.Set manifold pressure to (10) inch water
column. A 1/8" pipe plug on the burner
manifold can be removed for attaching a
pressure gauge. Remove the slotted
cover from the pressure regulator and
invert the plug. Replace the cover on
the regulator andthe manifold plug.
Regulator is now set at 10" W.C.
CHECKING FOR GAS LEAKS
Soap and water solution, or other material acceptable for the purpose of locating gas leaks shall be used. MATCHES, CANDLES, FLAME OR OTHER SOURCES OF IGNITION SHALL NOT BE USED FOR THIS PURPOSE. Check entire piping system for leaks.
PILOT LIGHTING INSTRUCTIONS
The broiler is equipped with (6) standing pilots Model 257 and (4) on Model 255B and should be lighted immediately after the gas is turned on.
1.Turn the burner valve knobs to "OFF"
position. CAUTION: If gas valves have
been on and gas has escaped through
the burners, turn unit off and wait 5
minutes to clear gas.
2.Remove valve knobs by pulling off.
3.Open front door panel.
4.Light pilots with match, using match
holder furnished with unit.
SHUTTING DOWN INSTRUCTIONS
Turn the burner valve knobs to the off
position to turn burners off.
PILOT LIGHT REGULATION
The pilot lights on this broiler have been adjusted at the factory. However, due to variations of gas pressure in different locations, the pilot light flames may have to be adjusted at installation location. Adjust pilot light flames as small as possible, but high enough to light burner immediately when burner valve is turned on high.
BURNER OPERATION
To ignite burners, turn burner valve knob to "HI" position. There are (6) burners for Model 257 and (4) for Model 255B, and each one is controlled by an individual high-low, on-off valve. An infinite number of broiling temperatures may be obtained by turning the burner valve knob to any position between high and low.
BURNER ADJUSTMENT
1.Turn burner valve knob to "HI" position.
2.Slowly decrease openings of air shutters to give a soft blue flame having luminous tips, then slowly increase openings to a point where the yellow tips disappear and a hard blue flame is obtained.
3.Set the low adjustment to maintain approximately 1/8" high flame by turning the screws inside the valve shafts when the knob is turned to low.
EXHAUST CANOPY
Open hearth broilers inherently create a good deal of heat and smoke and should be installed under an efficient exhaust hood with flame proof filters. A vertical distance of not less than 48" shall be provided between the top of the appliance and filters or any other combustible material.
AIR SUPPLY
Provisions for adequate air supply must be provided.
AIR INTAKES IN BOTTOM
Air for combustion enters from the bottom of the unit. Do not obstruct this area.
OPERATING INSTRUCTIONS
LIGHTING
When broiler is first lighted, it will smoke until the preservation oils and impurities are burned off. When it stops smoking, it is ready to use.
BROILING
Turn valves on and pre-heat unit on "HI" before attempting to broil. You will have to experiment with the grill settings and the valve settings for your particular meat products. We recommend that you set the grate at the full tilt position to start with. This position allows the grease to run down the rods into the grease tray, reducing flare ups.
CAUTION
Hot fat that drips onto the radiants causes some flare ups. Check water pans frequently and add a sufficient amount of water when necessary. Hot water vapors rising from the water pans and through the combustion chamber, helps reduce flare ups. Exercise care when using your broiler.
TILTING THE GRILL
CAUTION
Charbroilers are hot! Never attempt to change the grill position while meat products are cooking. Flare ups can occur unexpectedly. Turn off charbroiler and allow the charbroiler to cool.
Raise or lower grill by lifting the rod, at the back of the charbroiler, on which the grill rests, by its handles and placing the rod on the next step of the rod brackets. Use potholders or gloves to reposition the rod.
ADJUSTING HEAT PATTERN
The broiler has six (6) heat zones on Model 257 and four (4) on Model 255B, controlled by individual valves. It is possible through this arrangement to have a high heat or searing section, while having a low heat finishing or holding section. For the searing operation, set the valves for the section at a position of "HI" or close to it. For holding or finishing, set the valves closer to the "LOW" position on the dial. You select the heat pattern you like, and set the valves accordingly.
CLEANING
Clean regularly; remove grate sections to sink for washing. Rods rotate for easy scraping. Brush out carboned particles from the radiant area. Remove and wash water pan and grease trough. Wipe exterior stainless surfaces with detergent and a cloth. A non-abrasive cleaner can be used on caked areas.
GREASE PAN
A grease pan is located at the front, inside the water pan and can be removed from the front for cleaning. This pan should be checked and emptied when necessary.
CAUTION
EXERCISE CARE IN HANDLING THE GREASE PAN SINCE IT CONTAINS HOT GREASE.
AIR INTAKES IN BOTTOM
Air for combustion enters from the bottom of the unit. Do not obstruct this area.
REPAIRS AND SERVICE
This appliance should only be repaired or serviced by the factory or factory authorized personnel. Contact the factory or one of its representatives or a local service company for service or maintenance if required.
LOCKING STRIPS
Grease tight locking strips are available to join this broiler to any other Designer Series units to form a solid bank. Specify which models are to be banked and their order in the line up when ordering strips.
WATER PAN
There are (2) water pans on Model 257 and (1) on Model 255B which are located at the bottom of the unit, and are easily removed from the front of the unit. Water should be added to the water pans and replaced as necessary. The water pans help prevent flare ups and catch any grease that drips past the radiants.
RETAIN THIS MANUAL FOR FUTURE REFERENCE Part No. 2M-Y3213 Rev. G 10/2/95
PARTS LIST EFFECTIVE 07-08-02 RB
8H MODEL 255B Gas Charbroiler
Key
Number
Part
Number
Number
Per
Unit
Serial # 2552450 and ABOVE
2 H2-255072 1 Manifold Assembly Complete 3 H2-255065 1 Manifold 4 2V-Y2406 4 Hi-Lo Valve 5 2V-Y1177 4 Pilot Valve 6 G2-Y5357 4 Hood-Orifice (NAT) (Drilled #52) (for burner) 7 H2-3668 4 Hood-Orifices (LP) (Drilled #56) (for burner) (not shown)
8 2J-Y2391 4 Standing Pilot 8a 2A-Y1212 4 Pilot Orifice (not shown) 9 H2-Y2503 4 Pilot Tube (6”, 1/4” o.d. tubing) (not shown)
10 H2-255067 4 Burner Assembly 11 2R-9785 4 Hi-Lo Valve Knob 12 H2-Y2409 4 Air Mixer Cap
13 2F-Y2392 4 Upper Radiant
14 H2-Y2369 3 Lower Radiant
Description
15 H2-255064 3 Grate (
20-7/8” x 8”)
16 H2-255082 1 Grate Lift Assembly
17 H2-255061 1 Grate Support
18 H2-Y2662 1 Left Grate Lift Support
19 H2-Y2661 1 Right Grate Lift Support
20 H2-255079 1 Grease Drawer
21 H2-Y2380 1 Drip Pan
22 H2-255078 1 Rear Splash Guard
23 2C-9788 2 Magnetic Door Catch
24 2J-7961 1 Lighter Rod
25 2A-7612 4 Foot
26 2C-9348 4 Stud
2A-9347 4 Foot Extension
(not shown)
Z1-115006 4 Leg Assembly (not shown)
28 2J-Y3947 1 Pressure Regulator
29 H2-255068 1 Door Assembly
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED
INCLUDE MODEL AND SERIAL NUMBER
Some items are included for illustrative purposes only and in certain instances may not be available.
PAGE
1 OF 1
Star Manufacturing International, Inc.
PARTS LIST EFFECTIVE 07-10-02 RB
8H MODEL 257 Gas Charbroiler
Key
Number
Part
Number
Number
Per
Unit
1 H2-257003 1 Body Casing Assembly
2 H2-257015 1 Manifold Assembly Complete
3 H2-257010 1 Manifold
4 2V-Y2406 6 Hi-Lo Valve
5 2V-Y1177 6 Pilot Valve
6 G2-Y5357 6 Hood-Orifice (NAT) (
7 H2-3668 6 Hood-Orifices (LP) (Drilled #56) (for burner) (not shown)
8 2J-Y2391 6 Standing Pilot
8a 2A-Y1212 6 Pilot Orifice
9 H2-Y2503 6 Pilot Tube (6”, 1/4” o.d. tubing) (not shown)
10 H2-255067 6 Burner Assembly 11 2R-9785 6 Hi-Lo Valve Knob 12 H2-Y2409 6 Air Mixer Cap
13 2F-Y2392 6 Upper Radiant
14 H2-Y2369 5 Lower Radiant
15 H2-257009 5 Grate (
21-5/8” x 6-3/8”)
16 H2-257011 1 Grate Lift Assembly
17 H2-257012 1 Grate Support
18 H2-Y2662 1 Left Grate Lift Support
19 H2-Y2661 1 Right Grate Lift Support
Description
Drilled #52) (for burner)
(not shown)
20 H2-Y2380 1 Drip Pan (
18-11/16” x 20-5/32”) 21 H2-255079 1 Grease Drawer 22 H2-257014 1 Small Water Pan (9-9/16” x 20-5/32”)
23 2C-9788 3 Magnetic Door Catch 24 2J-7961 1 Lighter Rod
25 2A-7612 4 Foot 26 2C-9348 4 Stud
2A-9347 4 Foot Extension
(not shown)
Z1-115006 4 Leg Assembly (not shown) 28 2J-Y3947 1 Pressure Regulator
29 H2-257001 1 Door Assembly 30 H2-257013 1 Rear Splash Guard 31 H2-257008 1 Bottom Frame Assembly 32 H2-257006 1 Liner Assembly
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED
INCLUDE MODEL AND SERIAL NUMBER
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
PAGE
1 OF 1