1
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing the equipment.
This fryer is equipped for the voltage and wattage indicated on the nameplate mounted on the lower right corner of the element housing. It is designed for use on alternating current (AC) only. It is intended for use by properly trained personnel only.
CAUTION
For your protection we recommend that a qualified electrician install this appliance. He should be familiar with electrical installations, and all electrical codes. Proper connections and power supply are essential for efficient performance. The external wiring should be in conduit or an approved type of flexible cable suitable for operation at 90° C (194° F) and of a proper size to carry the load. The supply circuit should be properly fused and equipped with a means of disconnection, as required by local electrical code. THE BODY OF THE APPLIANCE SHOULD BE GROUNDED, DO NOT GROUND TO A GAS SUPPLY LINE. Four adjustable leg extensions are provided and should be installed for ease of cleaning. Level unit by adjusting the (4) feet which have an adjustment of 1" (25.4 mm) for accurate leveling and perfect line­up with other units.
LOCKING STRIPS
Grease tight locking strips are available to join this appliance to any other Designer Series units to form a solid bank. Specify which models are to be banked and their order in the line-up when ordering strips.
POWER SUPPLY
Models 115D and 115DL are wired at the factory for operation on a single phase power supply. The models 116C and 116CL are wired for operation on a three phase power supply. For specific wiring, check the wiring diagram.
DO NOT CONNECT TO DIRECT CURRENT (DC)
The installation of the appliance should conform to the:
NATIONAL ELECTRIC CODE AND ALL
LOCAL ELECTRIC CODES AND ORDINANCES
AND THE LOCAL ELECTRIC COMPANY
RULES AND REGULATIONS
CONNECTIONS OF FRYERS TO VENTILATOR FIRE DETECTION OR EXTINGUISHING SYSTEM
Star has manufactured this fryer to be not only one of the most efficient fryers made, but the safest. The unit is equipped with a terminal block (see enclosed wiring diagram) for tying into a fire detection system. This terminal is located at the rear of the unit in the area of the power connection point.
2
CONNECTIONS OF FRYERS (Cont'd)
Models 116C and 116CL To connect to the terminal block, remove the jumper and connect leads from the terminal block to a normally closed switch which is tied into the fire detection system of the ventilator hood. The switch in the detector system should be capable of handling 240 Volts and a minimum of 5 Amperes. DO NOT connect these leads into a voltage source. The voltage is supplied by the fryer.
Models 115D and 115DL Connect leads to terminal block from a normally open switch which is tied into the fire detection system of the ventilator hood. The switch in the detector system should be capable of handling 240 Volts at 1 Ampere. DO NOT connect these leads into a voltage source. The voltage is supplied by the fryer.
OPERATING INSTRUCTIONS
CONTROLS
A. ON/OFF TWO-POLE SWITCH
Located on the front panel is a two-pole switch which turns power on or off. An indicator light (Power On) is located on the control housing.
B . THERMOSTAT CONTROL
Located on the Control Housing, this control allows you to select the desired frying temperature. A signal light "Heating" indicates when the element is on. When the light goes off, the desired temperature has been reached.
C. HI-LIMIT THERMOSTAT - Should fat
temperatures reach 450° F (230° C), this control will shut off the power. Both lights on the control panel will go out. The fat temperature must cool to 400° F (202.4° C) and the circuit breaker switch located on the front panel must be reset. Should the hi-limit control activate twice in succession, the primary thermostat should be checked for malfunction by a qualified service technician.
CLEAN KETTLE BEFORE USING
Take out baskets, push and hold element catch, lift up on element lift handle until elements lock in a vertical position, and remove kettle. The kettle can be cleaned in a sink like any other pot or container.
ADDING FAT
Replace kettle and swing the element down, making fryer ready for use. Add fat - 12" fryers have a 15 lb. fat capacity, 24" fryers have a 30 lb. fat capacity. A fat level line on the rear of the kettle will guide you in determining the minimum cold fat level. A higher fat level can be used when frying bulky foods, such as chicken or fish cakes. The fat level should be chosen carefully so that the foaming action of the fat does not spill out of the kettle. If solid shortening is used, pack carefully around the elements.
FRYING
After fat has been added, turn the switch on and set the thermostat at 200° F (92.4° C). After the fat has melted, turn the thermostat to the desired setting. Included in this instruction booklet is a frying chart and some helpful hints on fat use. After the selected fat temperature has been reached, slowly lower half filled baskets into the fat. Do not overload baskets as this causes foods to be improperly fried.
Fryers with Bell Timers - After baskets have been lowered, set timers to desired time. If frying time is less than 2 minutes, turn timer beyond 5 minutes then back to desired time.
Fryers with Automatic Basket Lifts - Turn timer dial to desired frying time. To lower baskets, push in on center buttom timer. After selected frying time has elapsed, baskets will raise automatically. The timer dial need not be reset unless a different frying cycle is desired.
NOTE: The baskets may be raised before the end of the frying cycle by turning the timer to "0".
3
NOTE: Baskets should be allowed to drain after frying cycle. The kettle handles serve as basket hangers.
IDLING
During idle periods turn thermostat control to approximately 200° F (92.4° C). The fast recovery fryers can be brought up to frying temperature in a matter of minutes. Lowering the temperature during idle periods saves energy costs and prolongs fat life.
DRAINING KETTLE
Turn switch to "OFF" and allow fat to cool. Raise element to the first stop and allow to drain. Raise the element to the vertical position and siphon the oil out of the kettle. DO NOT ATTEMPT TO REMOVE THE KETTLE FILLED WITH HOT OIL. If you do not have a siphon, order one from your dealer or dip the oil out and strain into a container. After oil has been removed, remove the kettle and clean.
MAINTENANCE AND REPAIRS
Contact the factory or one of its representatives or a local service company for service or maintenance if required.
ACCESS TO MOTOR FUSE (Units with Automatic Lift)
1. Remove basket lifting hood.
2. Pivot up electrical element and lock in vertical position.
3. Remove kettle.
4. Remove drip panels located in the kettle opening.
5. The fuse holder is located on a fuse box at the front of the opening.
CLEANING THE EXTERIOR
The exterior surfaces can be cleaned by regularly wiping with a soft cloth. Any discoloration can be removed with a non-abrasive cleaner.
RETAIN THIS MANUAL FOR FUTURE REFERENCE Part No. 2M-7555 Rev. A 5/15/96
4
CAUTIONS FOR ALL DEEP FAT FRYERS
NEVER LEAVE AN OPERATING FRYER UNATTENDED
REMEMBER HOT OIL IS DANGEROUS - RESPECT IT!
1. Hot oil is dangerous - Severe burns can result when hot oil contacts the skin.
2. Locate your fryer in a protected place so it cannot be knocked over or off its support.
3. Keep your floors clean and free of grease so no one slips accidentally and contacts the hot fryer .
4. Hot oil is flammable - Keep open flames away from it and its vapors.
5. Keep areas and filters clean above your fryer - Oil soaked lint or dust can ignite easily and flames will spread rapidly .
8. If your fryer starts to smoke or boil abnormally , cut off the energy supply immediately and determine the reason for the smoking or boiling before attempting to use it again.
9. Be sure your energy supply is installed properly and in accordance with the local and national codes. There should be a convenient switch or gas valve, readily available, close to the fryer for such a shut-off procedure.
10.See that all of your help understand the hazards of hot fat. Instruct them on the proper action to take if something does not seem to be acting properly.
6. Install an automatic fire extinguisher over the fryer and in the exhaust duct.
7. Have your equipment checked regularly to insure its safe and proper functioning.
11.Instruct your personnel on what to do if there is a fat fire. Do not use water on an oil fire! Use only fire extinguishers of the approved type and never direct such extinguishers so as to blow the oil out of the oil container.
12.Never allow water to get in hot fat.
It can explode!
5