Stanley Black & Decker SM50 User Manual

Page 1
SM50
HYDRAULIC
USER MANUAL
Safety, Operation and Maintenance
© 2014 Stanley Black & Decker, Inc.
New Britain, CT 06053
U.S.A.
52724 2/2015 Ver. 6
Page 2
DECLARATION OF CONFORMITY
Weisbeck, Andy
DECLARATION OF CONFORMITY ÜBEREINSTIMMUNGS-ERKLARUNG DECLARATION DE CONFORMITE CEE DECLARACION DE CONFORMIDAD DICHIARAZIONE DI CONFORMITA
________________ ______________________________________________________
I, the undersigned: Ich, der Unterzeichnende: Je soussigné: El abajo firmante: lo sottoscritto:
hereby declare that the equipment specified hereunder: bestätige hiermit, daß erklaren Produkt genannten Werk oder Gerät: déclare que l’équipement visé ci-dessous: Por la presente declaro que el equipo se especifica a continuación: Dichiaro che le apparecchiature specificate di seguito:
Surname and First names/Familiennname und Vornamen/Nom et pr énom/Nombre y apellido/Cognome e nome
Hydraulic Tools
1. Category: Kategorie: Catégorie: Categoria: Categoria:
2. Make/Marke/Marque/Marca/Marca
3. Type/Typ/Type/Tipo/Tipo: SM50100, SM50100L
4. Serial number of equipment: Seriennummer des Geräts: Numéro de série de l’équipement: Numero de serie del equipo: Matricola dell´attrezzatura:
Has been manufactured in conformity with Wurde hergestellt in Übereinstimmung mit Est fabriqué conformément Ha sido fabricado de acuerdo con E’ stata costruita in conformitá con
Directive/Standards Richtlinie/Standards Directives/Normes Directriz/Los Normas Direttiva/Norme
EN Machinery Directive
5. Special Provisions: None Spezielle Bestimmungen: Dispositions particulières: Provisiones especiales: Disposizioni speciali:
No. Nr Numéro No n.
809:2009 2006/42/EC:2006
Stanley
Submersible Pump, Hydraulic
All
Approved body Prüfung durch Organisme agréé Aprobado Collaudato
Self Self
6. Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France.
Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione
Done at/Ort/Fait à/Dado en/Fatto a Stanley Hydraulic Tools, Milwaukie, Oregon USA
Signature/Unterschrift/Signature/Firma/Firma
Position/Position/Fonction/Cargo/Posizione Director of Product Development
2 ► SM50 User Manual
Date/Datum/le/Fecha/Data 1-5-11
Page 3
WARNING
TABLE OF CONTENTS
DECLARATION OF CONFORMITY .......................................................................................................................... 2
SAFETY SYMBOLS ..................................................................................................................................................4
SAFETY PRECAUTIONS .......................................................................................................................................... 5
TOOL STICKERS & TAGS ........................................................................................................................................6
HOSE TYPES ............................................................................................................................................................7
HOSE RECOMMENDATIONS ..................................................................................................................................8
FIGURE 1. TYPICAL HOSE CONNECTIONS .......................................................................................................8
HTMA REQUIREMENTS ...........................................................................................................................................9
OPERATION ............................................................................................................................................................10
TOOL PROTECTION & CARE ................................................................................................................................12
TROUBLESHOOTING ............................................................................................................................................13
SPECIFICATIONS ................................................................................................................................................... 14
ACCESSORIES.......................................................................................................................................................14
SM59 PARTS ILLUSTRATION ................................................................................................................................ 15
SM50 PARTS LIST ..................................................................................................................................................16
UNDERWATER TOOLS DEPTH GUIDELINE .........................................................................................................17
IMPORTANT
To ll out a Product Warranty Validation form, and for information on your warranty,
visit Stanleyhydraulics.com and select the Company tab, Warranty.
(NOTE: The warranty Validation record must be submitted to validate the warranty).
SERVICING: This manual contains safety, operation, and routine maintenance instructions. Stanley Hydraulic Tools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized
and certied dealer. Please read the following warning.
SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR
SERVICE OF THIS TOOL.
REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN
AUTHORIZED AND CERTIFIED DEALER.
For the nearest authorized and certied dealer, call Stanley Hydraulic Tools at the number listed on the back of this
manual and ask for a Customer Service Representative.
SM50 User Manual ◄ 3
Page 4
DANGER
WARNING
CAUTION
CAUTION
NOTICE
IMPORTANT
SAFETY SYMBOLS
Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair ac­tions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
This safety alert and signal word indicate an imminently hazardous situation which, if not avoided, will result in death or serious injury.
This safety alert and signal word indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This safety alert and signal word indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This signal word indicates a potentially hazardous situation which, if not avoid­ed, may result in property damage.
This signal word indicates a situation which, if not avoided, will result in damage to the equipment.
This signal word indicates a situation which, if not avoided, may result in dam­age to the equipment.
Always observe safety symbols. They are included for your safety and for the protection of the tool.
LOCAL SAFETY REGULATIONS
Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte­nance personnel.
4 ► SM50 User Manual
Page 5
SAFETY PRECAUTIONS
Tool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose.
These safety precautions are given for your safety. Re­view them carefully before operating the tool and before performing general maintenance or repairs.
Supervising personnel should develop additional pre-
cautions relating to the specic work area and local
safety regulations. If so, place the added precautions in the space provided in this manual.
The models SM50 Hydraulic Pump will provide safe and dependable service if operated in accordance with the instructions given in this manual. Read and understand this manual and any stickers and tags attached to the pump and hoses before operation. Failure to do so could result in personal injury or equipment damage.
Operator must start in a work area without bystand-
ers. The operator must be familiar with all prohibited work areas such as excessive slopes and danger­ous terrain conditions.
Establish a training program for all operators to en-
sure safe operations.
Do not operate the tool unless thoroughly trained or
under the supervision of an instructor.
Always wear safety equipment such as goggles,
head protection, and safety shoes at all times when operating the tool.
Do not inspect or clean the tool while the hydraulic
power source is connected. Accidental engagement of the tool can cause serious injury.
Do not operate this tool without rst reading the Op-
eration section of this manual.
Do not install or remove this tool while the hydraulic
power source is connected. Accidental engagement of the tool can cause serious injury.
Never operate the tool near energized transmission
lines. Know the location of buried or covered ser­vices before starting work.
Do not wear loose tting clothing when operating the tool. Loose tting clothing can get entangled with the
tool and cause serious injury.
Supply hoses must have a minimum working pres­sure rating of 2500 psi/175 bar.
Be sure all hose connections are tight.
The hydraulic circuit control valve must be in the
“OFF” position when coupling or uncoupling the tool. Wipe all couplers clean before connecting. Failure to do so may result in damage to the quick couplers and cause overheating. Use only lint-free cloths.
Do not operate the tool at oil temperatures above 140 ° F/60 ° C. Operation at higher oil temperatures can cause operator discomfort and may cause dam­age to the tool.
Do not operate a damaged, improperly adjusted, or incompletely assembled tool.
To avoid personal injury or equipment damage, all tool repair, maintenance and service must only be performed by authorized and properly trained per­sonnel.
Do not exceed the rated limits of the tool or use the tool for applications beyond its design capacity.
Always keep critical tool markings, such as labels and warning stickers legible.
Always replace parts with replacement parts recom­mended by Stanley Hydraulic Tools.
Check fastener tightness often and before each use daily.
SM50 User Manual ◄ 5
Page 6
52728
CAUTION
SM50 Combined Decal
TOOL STICKERS & TAGS
NOTE:
THE INFORMATION LISTED ON THE STICKERS SHOWN, MUST BE LEGIBLE AT ALL TIMES.
REPLACE DECALS IF THEY BECOME WORN OR DAM­AGED. REPLACEMENTS ARE AVAILABLE FROM YOUR LO­CAL STANLEY DISTRIBUTOR.
The safety tag (P/N 15875) at right is attached to the tool when shipped from the factory. Read and understand the safety instructions listed on this tag before removal. We suggest you retain this tag and attach it to the tool when not in use.
1. FAILURE TO USE HYDRAULIC HOSE LABELED AND CER­TIFIED AS NON-CONDUCTIVE WHEN USING HYDRAULIC TOOLS ON OR NEAR ELECTRICAL LINES MAY RESULT IN DEATH OR SERIOUS INJURY.
BEFORE USING HOSE LABELED AND CERTIFIED AS NON- CONDUCTIVE ON OR NEAR ELECTRIC LINES BE SURE THE HOSE IS MAINTAINED AS NON-CONDUCTIVE. THE HOSE SHOULD BE REGULARLY TESTED FOR ELECTRIC CUR­RENT LEAKAGE IN ACCORDANCE WITH YOUR SAFETY DEPARTMENT INSTRUCTIONS.
2. A HYDRAULIC LEAK OR BURST MAY CAUSE OIL INJEC­TION INTO THE BODY OR CAUSE OTHER SEVERE PERSONAL INJURY.
A. DO NOT EXCEED SPECIFIED FLOW AND PRESSURE
FOR THIS TOOL. EXCESS FLOW OR PRESSURE MAY CAUSE A LEAK OR BURST.
B. DO NOT EXCEED RATED WORKING PRESSURE OF
HYDRAULIC HOSE USED WITH THIS TOOL. EXCESS PRESSURE MAY CAUSE A LEAK OR BURST.
C. CHECK TOOL HOSE COUPLERS AND CONNECTORS
DAILY FOR LEAKS. DO NOT FEEL FOR LEAKS WITH YOUR HANDS. CONTACT WITH A LEAK MAY RESULT IN SEVERE PERSONAL INJURY.
IMPORTANT
READ OPERATION MANUAL AND
SAFETY INSTRUCTIONS FOR THIS
TOOL BEFORE USING IT.
USE ONLY PARTS AND REPAIR
PROCEDURES APPROVED BY
STANLEY AND DESCRIBED IN THE
OPERATION MANUAL.
TAG TO BE REMOVED ONLY BY
TOOL OPERATOR.
SEE OTHER SIDE
DANGERDANGER
D. DO NOT LIFT OR CARRY TOOL BY THE HOSES. DO
NOT ABUSE HOSE. DO NOT USE KINKED, TORN OR DAMAGED HOSE.
3. MAKE SURE HYDRAULIC HOSES ARE PROPERLY CON­NECTED TO THE TOOL BEFORE PRESSURING SYSTEM. SYSTEM PRESSURE HOSE MUST ALWAYS BE CON­NECTED TO TOOL “IN” PORT. SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL “OUT” PORT. REVERSING CONNECTIONS MAY CAUSE REVERSE TOOL OPERATION WHICH CAN RESULT IN SEVERE PERSONAL INJURY.
4. DO NOT CONNECT OPEN-CENTER TOOLS TO CLOSED­CENTER HYDRAULIC SYSTEMS. THIS MAY RESULT IN LOSS OF OTHER HYDRAULIC FUNCTIONS POWERED BY THE SAME SYSTEM AND/OR SEVERE PERSONAL INJURY.
5. BYSTANDERS MAY BE INJURED IN YOUR WORK AREA. KEEP BYSTANDERS CLEAR OF YOUR WORK AREA.
6. WEAR HEARING, EYE, FOOT, HAND AND HEAD PRO­TECTION.
7. TO AVOID PERSONAL INJURY OR EQUIPMENT DAMAGE, ALL TOOL REPAIR MAINTENANCE AND SERVICE MUST ONLY BE PERFORMED BY AUTHORIZED AND PROPERLY TRAINED PERSONNEL.
IMPORTANT
READ OPERATION MANUAL AND
SAFETY INSTRUCTIONS FOR THIS
TOOL BEFORE USING IT.
USE ONLY PARTS AND REPAIR
PROCEDURES APPROVED BY
STANLEY AND DESCRIBED IN THE
OPERATION MANUAL.
TAG TO BE REMOVED ONLY BY
TOOL OPERATOR.
SEE OTHER SIDE
6 ► SM50 User Manual
SAFETY TAG P/N 15875 (Shown smaller then actual size)
Page 7
HOSE TYPES
The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy­draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic Tools. They are:
Certied non-conductive — constructed of thermoplastic or synthetic rubber inner tube, synthetic ber braid
reinforcement, and weather resistant thermoplastic or synthetic rubber cover. Hose labeled certied non- conductive is the only hose authorized for use near electrical conductors.
Wire-braided (conductive) — constructed of synthetic rubber inner tube, single or double wire braid reinforce­ment, and weather resistant synthetic rubber cover. This hose is conductive and must never be used near
electrical conductors.
Fabric-braided (not certied or labeled non-conductive) — constructed of thermoplastic or synthetic rubber in­ner tube, synthetic ber braid reinforcement, and weather resistant thermoplastic or synthetic rubber cover. This
hose is not certied non-conductive and must never be used near electrical conductors.
HOSE SAFETY TAGS
To help ensure your safety, the following DANGER tags are attached to all hose purchased from Stanley Hydraulic Tools. DO NOT REMOVE THESE TAGS.
If the information on a tag is illegible because of wear or damage, replace the tag immediately. A new tag may be obtained from your Stanley Distributor.
THE TAG SHOWN BELOW IS ATTACHED TO “CERTIFIED NON-CONDUCTIVE” HOSE
DANGER
1. FAILURE TO USE HYDRAULIC HOSE LABELED AND CERTIFIED AS NON-CONDUCTIVE WHEN USING HYDRAULIC TOOLS ON OR NEAR ELECTRIC LINES MAY RESULT IN DEATH OR SERIOUS INJURY.
FOR PROPER AND SAFE OPERATION MAKE SURE THAT YOU HAVE BEEN PROP­ERLY TRAINED IN CORRECT PROCEDURES REQUIRED FOR WORK ON OR AROUND ELECTRIC LINES.
2. BEFORE USING HYDRAULIC HOSE LABELED AND CERTIFIED AS NON-CONDUCTIVE ON OR NEAR ELECTRIC LINES. WIPE THE ENTIRE LENGTH OF THE HOSE AND FIT­TING WITH A CLEAN DRY ABSORBENT CLOTH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUM ALLOWABLE CURRENT LEAKAGE IN ACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS.
DO NOT REMOVE THIS TAG
SEE OTHER SIDE
SIDE 1
3. DO NOT EXCEED HOSE WORKING PRESSURE OR ABUSE HOSE. IMPROPER USE
OR HANDLING OF HOSE COULD RESULT IN BURST OR OTHER HOSE FAILURE. KEEP HOSE AS FAR AWAY AS POSSIBLE FROM BODY AND DO NOT PERMIT DIRECT CONTACT DURING USE. CONTACT AT THE BURST CAN CAUSE BODILY INJECTION AND SEVERE PERSONAL INJURY.
4. HANDLE AND ROUTE HOSE CAREFULLY TO AVOID KINKING, ABRASION, CUTTING, OR
CONTACT WITH HIGH TEMPERATURE SURFACES. DO NOT USE IF KINKED. DO NOT USE HOSE TO PULL OR LIFT TOOLS, POWER UNITS, ETC.
5. CHECK ENTIRE HOSE FOR CUTS CRACKS LEAKS ABRASIONS, BULGES, OR DAM­AGE TO COUPLINGS IF ANY OF THESE CONDITIONS EXIST, REPLACE THE HOSE IMMEDIATELY. NEVER USE TAPE OR ANY DEVICE TO ATTEMPT TO MEND THE HOSE.
6. AFTER EACH USE STORE IN A CLEAN DRY AREA.
(Shown smaller than actual size)
DANGER
DANGER
SEE OTHER SIDE
SIDE 2
THE TAG SHOWN BELOW IS ATTACHED TO “CONDUCTIVE” HOSE.
DANGER
DANGER
1. DO NOT USE THIS HYDRAULIC HOSE ON OR NEAR ELECTRIC LINES. THIS HOSE IS NOT LABELED OR CERTIFIED AS NON-CONDUCTIVE. USING THIS HOSE ON OR NEAR ELECTRICAL LINES MAY RESULT IN DEATH OR SERIOUS INJURY.
2. FOR PROPER AND SAFE OPERATION MAKE SURE THAT YOU HAVE BEEN PROPERLY TRAINED IN CORRECT PROCEDURES REQUIRED FOR WORK ON OR AROUND ELEC­TRIC LINES.
3. DO NOT EXCEED HOSE WORKING PRESSURE OR ABUSE HOSE. IMPROPER USE OR HANDLING OF HOSE COULD RESULT IN BURST OR OTHER HOSE FAILURE. KEEP HOSE AS FAR AWAY AS POSSIBLE FROM BODY AND DO NOT PERMIT DIRECT CONTACT DURING USE. CONTACT AT THE BURST CAN CAUSE BODILY INJECTION AND SEVERE PERSONAL INJURY.
4. HANDLE AND ROUTE HOSE CAREFULLY TO AVOID KINKING, CUTTING, OR CONTACT WITH HIGH TEMPERATURE SURFACES. DO NOT USE IF KINKED. DO NOT USE HOSE TO PULL OR LIFT TOOLS, POWER UNITS, ETC.
DO NOT REMOVE THIS TAG
SEE OTHER SIDE
SIDE 1
5. CHECK ENTIRE HOSE FOR CUTS CRACKS LEAKS ABRASIONS, BULGES, OR DAMAGE TO COUPLINGS IF ANY OF THESE CONDITIONS EXIST, REPLACE THE HOSE IMMEDIATELY. NEVER USE TAPE OR ANY DEVICE TO ATTEMPT TO MEND THE HOSE.
6. AFTER EACH USE STORE IN A CLEAN DRY AREA.
(Shown smaller than actual size)
DANGER
SEE OTHER SIDE
SIDE 2
DO NOT REMOVE THIS TAG
DO NOT REMOVE THIS TAG
SM50 User Manual ◄ 7
Page 8
Min. Working Pressure
USE
(Press/Return)
HOSE RECOMMENDATIONS
Certied Non-Conductive Hose - Fiber Braid - for Utility Bucket Trucks
Oil Flow Hose Lengths Inside Diameter
GPM LPM FEET METERS INCH MM PSI BAR
4-9 15-34 up to 10 up to 3 3/8 10 Both 2250 155
Conductive Hose - Wire Braid or Fiber Braid -DO NOT USE NEAR ELECTRICAL CONDUCTORS
4-6 15-23 up to 25 up to 7.5 3/8 10 Both 2500 175
4-6 15-23 26-100 7.5-30 1/2 13 Both 2500 175
5-10.5 19-40 up to 50 up to 15 1/2 13 Both 2500 175
5-10.5 19-40 51-100 15-30 5/8 16 Both 2500 175
5/8 16 Pressure 2500 175
3/4 19 Return 2500 175
5-10.5 19-40 100-300 30-90
10-13 38-49 up to 50 up to 15 5/8 16 Both 2500 175
5/8 16 Pressure 2500 175
3/4 19 Return 2500 175
10-13 38-49 51-100 15-30
3/4 19 Pressure 2500 175
1 25.4 Return 2500 175
10-13 38-49 100-200 30-60
5/8 16 Pressure 2500 175
13-16 49-60 up to 25 up to 8
3/4 19 Return 2500 175
3/4 19 Pressure 2500 175
1 25.4 Return 2500 175
13-16 49-60 26-100 8-30
PRESSURE
<<< FLOW
RETURN
FLOW >>>
Figure 1. Typical Hose Connections
Tool to Hydraulic Circuit Hose
Recommendations
The chart to the right shows recommended
minimum hose diameters for various hose
lengths based on gallons per minute (gpm)/
liters per minute (lpm). These recommenda-
tions are intended to keep return line pressure
(back pressure) to a minimum acceptable lev-
el to ensure maximum tool performance.
8 ► SM50 User Manual
This chart is intended to be used for hydraulic
tool applications only based on Stanley Hy-
draulic Tools tool operating requirements and
should not be used for any other applications.
All hydraulic hose must have at least a rated
minimum working pressure equal to the maxi-
mum hydraulic system relief valve setting.
All hydraulic hose must meet or exceed
specications as set forth by SAE J517.
Page 9
HTMA / EHTMA REQUIREMENTS
HTMA / EHTMA REQUIREMENTS
HTMA HYDRAULIC SYSTEM REQUIREMENTS
Flow Range
Nominal Operating Pressure (at the power supply outlet)
System relief valve setting (at the power supply outlet)
Maximum back pressure (at tool end of the return hose)
Measured at a max. uid viscosity of:
(at min. operating temperature)
Temperature: Sufcient heat rejection capacity to limit max. uid temperature to:
(at max. expected ambient temperature)
Min. cooling capacity at a temperature
difference of between ambient and uid
temps NOTE: Do not operate the tool at oil temperatures above 140° F (60° C). Operation at higher temperatures can cause operator discomfort at the tool.
Filter
Min. full-ow ltration Sized for ow of at least:
(For cold temp. startup and max. dirt-holding capacity)
4-6 gpm 7-9 gpm 9-10.5 gpm 11-13 gpm (15-23 lpm) (26-34 lpm) (34-40 lpm) (42-49 lpm) 1500 psi 1500 psi 1500 psi 1500 psi (103 bar) (103 bar) (103 bar) (103 bar)
2100-2250 psi 2100-2250 psi 2200-2300 psi 2100-2250 psi (145-155 bar) (145-155 bar) (152-159 bar) (145-155 bar)
250 psi 250 psi 250 psi 250 psi (17 bar) (17 bar) (17 bar) (17 bar)
400 ssu* 400 ssu* 400 ssu* 400 ssu* (82 centistokes) (82 centistokes) (82 centistokes) (82 centistokes)
140° F 140° F 140° F 140° F (60° C) (60° C) (60° C) (60° C)
3 hp 5 hp 6 hp 7 hp (2.24 kW) (3.73 kW) (5.22 kW) (4.47 kW) 40° F 40° F 40° F 40° F (22° C) (22° C) (22° C) (22° C)
25 microns 25 microns 25 microns 25 microns 30 gpm 30 gpm 30 gpm 30 gpm (114 lpm) (114 lpm) (114 lpm) (114 lpm)
TYPE I TYPE II
TOOL TYPE
TYPE RR
TYPE III
Hydraulic uid Petroleum based
(premium grade, anti-wear, non-conductive) Viscosity (at min. and max. operating temps)
NOTE:
When choosing hydraulic uid, the expected oil temperature extremes that will be experienced in service determine the most suitable temperature viscosity characteristics. Hydraulic uids with a viscosity index over 140 will meet the requirements
over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal
EHTMA
100-400 ssu* 100-400 ssu* 100-400 ssu* 100-400 ssu* (20-82 centistokes)
CLASSIFICATION HYDRAULIC SYSTEM REQUIREMENTS
Flow Range
Nominal Operating Pressure (at the power supply outlet)
System relief valve setting (at the power supply outlet)
NOTE: These are general hydraulic system requirements. See tool specication page for tool specic requirements
B
3.5-4.3 gpm 4.7-5.8 gpm 7.1-8.7 gpm 9.5-11.6 gpm 11.8-14.5 gpm (13.5-16.5 lpm) (18-22 lpm) (27-33 lpm) (36-44 lpm) (45-55 lpm) 1870 psi 1500 psi 1500 psi 1500 psi 1500 psi (129 bar) (103 bar) (103 bar) (103 bar) (103 bar)
2495 psi 2000 psi 2000 psi 2000 psi 2000 psi (172 bar) (138 bar) (138 bar) (138 bar) (138 bar)
C
D
SM50 User Manual ◄ 9
Page 10
IMPORTANT
OPERATION
PREOPERATION PROCEDURES
CHECK POWER SOURCE
1. Using a calibrated ow meter and pres sure gauge, make sure the hydraulic power source develops a
ow of 7–12 gpm/26–45 Ipm at 1000–2000 psi/70–
140 bar.
2. Make certain that the power source is equipped with a relief valve set to open at 2100 psi/145 bar maxi­mum.
3. Make certain that the power source re turn pressure does not exceed 250 psi/17 bar.
4. Make sure the trash pump inlet is clear of debris. Remove any obstruction before operating. Refer to PUMP CLEANING PROCEDURES.
CONNECT HOSES
1. Wipe all hose couplers with a clean lint free cloth before making connections.
2. Connect the hoses from the hydraulic power source to the couplers on the trash pump or trash pump hoses. It is a good practice to connect return hose
rst and disconnect it last to minimize or avoid
trapped pressure within the trash pump motor.
NOTE: If uncoupled hoses are left in the sun, pressure in-
crease inside the hoses might make them difcult to
connect. Whenever possible, connect the free ends of the hoses together.
3. Observe the arrow on the couplers to ensure that the
ow is in the proper direc tion. The female coupler on
the trash pump is the inlet (pressure) coupler.
PUMP OPERATION
1. Observe all safety precautions.
NOTE: The SM50 is not designed for use with a suction
pipe inlet. The diameter of the suction screen at the bottom of the pump provides maximum pump ef-
ciency. Reducing the size of this inlet will greatly
reduce pump performance.
2. Connect a hose tted with a 3 inch/76.2 mm female camlock coupler to the pump outlet tting. Make sure the tting is securely tightened. For best perfor-
mance, keep the hose as short as possible and lay it out to avoid sharp bends or kinks.
3. Lower the pump into the liquid to be pumped. Locate the outlet end of the discharge hose to disperse the liquid as required. Remove any kinks from the hose
to assure maximum water ow.
Never point the hose at bystanders.
4.
Turn on the hydraulic power source. Watch for sol­ids in the liquid being pumped. If solids are exces­sive, the discharge ow might decrease. If this hap­pens, stop the pump and check for the cause of the problem.
Under some conditions, the liquid being pumped might be slowed enough so It can no longer push particles in the liquid. If this happens, particles can accumulate in the hose and backup the pumping chamber, causing further restriction. The impel­ler then acts as a “grinding wheel which causes
acceler ated pump wear. Reduced liquid ow can be
caused by the following:
The pump sinks into solids at the bottom of the hole.
The end of the outlet hose is too high, causing an excessive lift height for the column of liquid being pushed by the trash pump. This slows the
ow of liquid to a level where it can no longer
carry solids out the end of the hose.
The ow and pressure of hydraulic uid to the
pump is too low, which re duces impeller speed. A 20% de crease in hydraulic uid ow can re­duce pump performance by 50%. When operat-
ing at reduced hydraulic ow and pressure, the
end of the outlet hose should not be more than 30 ft/9 m above the liquid.
5. When pumping is complete, set the hy draulic control valve to the “OFF” posi tion. Lift the pump from the work area.
COLD WEATHER OPERATION
If the trash pump is to be used during cold weather,
preheat the hydraulic uid at low power source speed. When using the nor mally recommended uids, uid
should be at or above 50 °F/10 °C (400 ssu/82 centi­stokes) before use.
Damage to the hydraulic system or pump motor seals
can result from use with uid that is too viscous or thick.
10 ► SM50 User Manual
Page 11
OPERATION
CLEANING THE PUMPING CHAMBER
Debris such as weeds, sand and other solids may be­come trapped in the water hose and pumping chamber. This can reduce pump performance. It is important that the pumping chamber be kept clean at all times. The chamber can be cleaned as follows:
1. Remove motor and impeller by removing the two M12 × 1.75 Hex Head capscrews.
2. Remove all debris from the pump screen.
3. Thoroughly clean the volute and impeller. Do not remove the impeller unless necessary for repair or replacement or to remove trapped debris.
4. Assemble the motor and impeller to the volute. Clean the capscrews and lubricate the threads with underwater grease before installation.
5. Remove all debris from the hose. Otherwise, solids
will backll the pump.
SM50 User Manual ◄ 11
Page 12
NOTICE
TOOL PROTECTION & CARE
In addition to the Safety Precautions found
in this manual, observe the following for
equipment protection and care.
Make sure all couplers are wiped clean before con­nection.
The hydraulic circuit control valve must be in the “OFF” position when coupling or uncoupling hydrau­lic tools. Failure to do so may result in damage to the quick couples and cause overheating of the hy­draulic system.
Always store the tool in a clean dry space, safe from damage or pilferage.
Make sure the circuit PRESSURE hose (with male quick disconnect) is connected to the “IN” port. The circuit RETURN hose (with female quick disconnect) is connected to the opposite port. Do not reverse cir-
cuit ow. This can cause damage to internal seals.
Always replace hoses, couplings and other parts
with replacement parts recommended by Stanley Hydraulic Tools. Supply hoses must have a mini­mum working pressure rating of 2500 psi/172 bar.
Do not exceed the rated ow (see Specications) in this manual for correct ow rate and model number.
Rapid failure of the internal seals may result.
Always keep critical tool markings, such as warning stickers and tags legible.
Do not use the tool for applications it was not de­signed for.
Tool repair should be performed by experienced personnel only.
Make certain that the recommended relief valves are installed in the pressure side of the system.
Do not use the tool for applications for which it was not intended.
12 ► SM50 User Manual
Page 13
TROUBLESHOOTING
If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.
When diagnosing faults in operation, always make sure the hydraulic power source is supplying the correct hydrau-
lic ow and pressure as listed in the table. Use a owmeter know to be accurate. Check the ow with the hydraulic uid temperature at least 80 °F/27 °C.
PROBLEM CAUSE SOLUTION
Pump will not start. No hydraulic uid ow or pressure. Turn on power unit and check that 7–12
gpm/26–45 lpm at 1000-2000 psi/70–140
bar is available at the pump.
Defective couplers. Check the couplers. Replace if necessary.
Impeller jammed with debris. Clean the pumping chamber as described in
the Maintenance section in this manual.
Impeller rubbing against wear plates.
Defective hydraulic motor. Repair or replace motor.
Poor pump performance. Hydraulic ow reversed. Check that the hoses are correctly
Improper hydraulic uid ow. Check that 7–12 gpm/26-45 lpm at 1000–
Pump submersed in sediment. Lift the pump from the bottom of the hole or
Trash pump inlet restricted. Remove suction screen and thoroughly
Discharge hose kinked or restricted.
Discharge hose too small. Use a 3-inch diameter re hose.
Water lift too high. Lower the outlet end of the discharge hose.
Impeller worn or damaged. Check impeller for damage and excessive
Pump not matched to application Obtain higher capacity pump.
Hose used on suction side of pump.
Poor pump performance with excessive wear.
Too many solids in the water. Water speed out of the hose may be too slow, therefore hose and pump load up with solids.
Check and adjust the impeller clearance as described in the Service Manual.
connected to the pump motor ports. The female coupler should be connected to the
“IN” port. The return uid must never ow
through a reversing valve.
2000 psi/70–140 bar is available at the trash pump. A 20% decrease in ow can result in
a 50% decrease in pump performance.
chamber. Use a at support under the pump
if necessary.
clean. Reassemble.
Straighten the hose. If the hose must bend at the top of the hole, use a piece of split rigid conduit with large diameter of the expanded hose. This keeps the hose from kinking.
Increase hydraulic ow (12 gpm/45 lpm
max).
wear. Replace if necessary.
Remove. Use no plumbing on suction side of pump.
Reduce solids content. Increase pump speed.
SM50 User Manual ◄ 13
Page 14
SPECIFICATIONS
Capacity......................................................................................................................................... 500 gpm/1890 lpm
Weight .....................................................................................................................................................21 lbs/9.5 kg
Length................................................................................................................................................ 10.5 in./26.7 cm
Width .................................................................................................................................................... 10 in./25.4 cm
Pressure ............................................................................................................................1000-2000 psi/70–140 bar
Flow Range ................................................................................................................................7–12 gpm/26-45 lpm
Maximum Flow .................................................................................................................................... 12 gpm/45 lpm
Porting ...................................................................................................................................................–8SAE O-ring
Connect Size and Type ......................................................................3/8 in. Flush Face Quick Disconnect Couplers
Discharge Diameter .................................................................................................................................. 3 in./7.6 cm
Sound Pressure ..................................................................................................................................<85 dBA @ 1 m
ACCESSORIES
Description Part No.
Adapter, 3 in. NPT/3 in. Camlock Male..............................................................................................................52720
Lay-Flat Discharge Hose, 3 in. × 25 ft with Camlock Fittings ............................................................................56761
Adapter, 3 in. Femaile Camlock × Male Fire Hose (nh) Thread ........................................................................15248
14 ► SM50 User Manual
Page 15
SM50 PARTS ILLUSTRATION
65132 MOTOR ASSEM­BLY USED ON SUMP PUMPS WITH SERIAL NUMBERS 600 AND ABOVE, THIS MOTOR CAN ONLY BE PUR­CHASED AS AN ASSEM­BLY. INDIVIDUAL PARTS ARE NOT AVAILABLE.
SM50 User Manual ◄ 15
Page 16
SM50 PARTS LIST
ITEM NO.
1 52669 1 VOLUTE
2 52720 1 CAMLOCK COUPLING 3 IN.
3 13815 1 HSHCS 5/16 – 18 × 3/4
4 56763 1 WASHER
5 00635 1 KEY
6 52671 1 IMPELLER
7 31032 1* SHIM .020 (* NOTE QTY WHEN
8 31033 1* SHIM .010 (* NOTE QTY WHEN
9 31034 1* SHIM .005 (* NOTE QTY WHEN
10 52716 1 V-RING
11 65132 1 MOTOR ASSEMBLY
12 52728 1 SM50 COMBINED STICKER
13 52718 2 HHCS M12-1.75 X 30MM
14 58857 1 MALE FLUSH FACE COUPLER
15 58856 1 FEMALE FLUSH FACE COUPLER
PART NO. QTY DESCRIPTION
DISASSEMBLING TOOL)
DISASSEMBLING TOOL)
DISASSEMBLING TOOL)
NOSE 3/8 NPT
BODY 3/8 NPT
58718 1 COUPLER SET (MALE & FEMALE)
52758 1 REPAIR KIT
66398 1 SEAL KIT FOR 65132 MOTOR
(SERIAL # 600 AND ABOVE)
NOTE:
ALL SM50 PUMPS WITH A SERIAL NUMBER OF 600 AND ABOVE, COME SHIPPED WITH P/N 65132 MOTOR ASSEMBLY INSTALLED. A SEPARATE SEAL KIT 66398 IS AVAILABLE FOR THIS MOTOR.
IF YOU HAVE A SM50 WITH SERIAL # 599 AND BELOW CONTACT STANLEY CUSTOMER SERVICE FOR PARTS.
16 ► SM50 User Manual
Page 17
UNDERWATER TOOLS DEPTH GUIDELINE
UNDERWATER MODELS ONLY
CAUTION
DO NOT USE HYDRAULIC TOOLS UNDER-
WATER THAT ARE NOT DESIGNATED AS
AN “UNDERWATER” MODEL, OR THIS
WILL RESULT IN DAMAGE TO THE TOOL.
For underwater hydraulic tools the applications are broken down into four quadrants depending on type of tool and method of operation.
The types of tools are percussive and rotational, each with different characteristics allowing for dif­ferent depth operation. With percussive tools, the nitrogen accumulator PSI must counter the in­crease in ambient pressure found at lower depths. Since there is a maximum PSI for percussive tools they are limited to certain depths. Rotational tools do not have accumulators and thus capable of deeper depths.
Operation Overview
Percussive Rotational
Tools: Breakers, Hammer Drills and Chipping Hammers
Max Depth: 500' -
DiverROV
limitations due to accumulator PSI max (increase 40 PSI for every 100')
Tools: Breakers, Hammer Drills and Chipping Hammers
Max Depth: 500' ­limitations due to accumulator PSI max (increase 40 PSI for every 100')
Tools: Grinders, Saws, Chain Saws
Max Depth: 1000' ­Reference hose sizing guide below
Tools: Grinders, Saws, Chain Saws
Max Depth: 1000' ­Reference hose sizing guide below
The methods are broken into diver operated or remote operated vehicle (ROV). ROV's can reach lower depths and with an on-board hydraulic power source that is depth compensated, can operate hydraulic tools at depths of thousands of feet. ROV operation is still limited to the tool, for example a percussive tool has the same depth limitation whether ROV or diver operated.
Recommended Hose Diameters
Depth (ft) 8 GPM 12 GPM 100 5/8” 5/8” 300 3/4” 1” 600 1” 1” 1000 1” 1-1/4”
SM50 User Manual ◄ 17
Page 18
Stanley Hydraulic Tools
3810 SE Naef Road
Milwaukie, Oregon 97267-5698 USA
(503) 659-5660 / Fax (503) 652-1780
www.stanleyhydraulics.com
Loading...