Weisbeck, Andy
Directive/Standards
No.
Approved body
SS-EN
60974-10
Self
DECLARATION OF CONFORMITY ÜBEREINSTIMMUNGS-ERKLARUNG DECLARATION DE CONFORMITE CEE DECLARACION DE CONFORMIDAD DICHIARAZIONE DI CONFORMITA
______________________________________________________________________
I, the undersigned: Ich, der Unterzeichnende: Je soussigné: El abajo firmante: lo sottoscritto:
hereby declare that the equipment specified hereunder: bestätige hiermit, daß erklaren Produkt genannten Werk oder Gerät: déclare que l’équipement visé ci-dessous: Por la presente declaro que el equipo se especifica a continuación: Dichiaro che le apparecchiature specificate di seguito:
Surname and First names/Familiennname und Vornamen/Nom et pr énom/Nombre y apellido/Cognome e nome
Hydraulic Tools
1. Category: Kategorie: Catégorie: Categoria: Categoria:
2. Make/Marke/Marque/Marca/Marca
3. Type/Typ/Type/Tipo/Tipo: EP30 / EP60
4. Serial number of equipment: Seriennummer des Geräts: Numéro de série de l’équipement: Numero de serie del equipo: Matricola dell´attrezzatura:
Has been manufactured in conformity with Wurde hergestellt in Übereinstimmung mit Est fabriqué conformément Ha sido fabricado de acuerdo con E’ stata costruita in conformitá con
Richtlinie/Standards Directives/Normes Directriz/Los Normas Direttiva/Norme
EMC Directive
Nr Numéro No n.
2004/108/EC
Pin Braze / Safebond Unit (Product Group-Railroad)
Stanley Hydraulic Tools
All
Prüfung durch Organisme agréé Aprobado Collaudato
Self
5. Special Provisions: None Spezielle Bestimmungen: Dispositions particulières: Provisiones especiales: Disposizioni speciali:
6. Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France.
Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione
Done at/Ort/Fait à/Dado en/Fatto a Stanley Hydraulic Tools, Milwaukie, Oregon USA
Signature/Unterschrift/Signature/Firma/Firma
Position/Position/Fonction/Cargo/Posizione Director of Product Development
2 ► EP30200 User Manual
Date/Datum/le/Fecha/Data 1-10-11
TABLE OF CONTENTS
DECLARATION OF CONFORMITY ................................................................................................................................... 2
WARRANTY .......................................................................................................................................................................3
SAFETY SYMBOLS ...........................................................................................................................................................4
SAFETY PRECAUTIONS ................................................................................................................................................... 5
OPERATION EP30200 ......................................................................................................................................... 6 THRU 9
TROUBLESHOOTING .....................................................................................................................................................10
EQUIPMENT MAINTENANCE & CARE ........................................................................................................................... 11
SPECIFICATIONS ............................................................................................................................................................ 12
ACCESSORIES.................................................................................................................................................13 THRU 17
EP30200 PARTS ILLUSTRATION....................................................................................................................................18
EP30200 PARTS LIST......................................................................................................................................................19
IMPORTANT
To ll out a Product Warranty Validation form, and for information on your warranty,
visit Stanleyhydraulics.com and select the Company tab, Warranty.
(NOTE: The warranty Validation record must be submitted to validate the warranty).
SERVICING: This manual contains safety, operation, and routine maintenance instructions. Stanley Hydraulic Tools recommends that servicing of the unit, other than routine maintenance, must be performed by an authorized and
certied dealer. Please read the following warning.
WARNING
SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR
SERVICE OF THIS TOOL.
REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN
AUTHORIZED AND CERTIFIED DEALER.
For the nearest authorized and certied dealer, call Stanley Hydraulic Tools at the number listed on the back of this
manual and ask for a Customer Service Representative.
EP30200 User Manual ◄ 3
DANGER
WARNING
CAUTION
NOTICE
IMPORTANT
SAFETY SYMBOLS
Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair ac­tions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
This safety alert and signal word indicate an imminently hazardous situation which, if not avoided, will result in death or serious injury.
This safety alert and signal word indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This safety alert and signal word indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Always observe safety symbols. They are included for your safety and for the protection of the tool.
This signal word indicates a potentially hazardous situation which, if not avoid­ed, may result in property damage.
This signal word indicates a situation which, if not avoided, will result in damage to the equipment.
This signal word indicates a situation which, if not avoided, may result in dam­age to the equipment.
LOCAL SAFETY REGULATIONS
Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte­nance personnel.
4 ► EP30200 User Manual
SAFETY PRECAUTIONS
Tool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose.
These safety precautions are given for your safety. Re­view them carefully before operating the tool and before performing general maintenance or repairs.
Supervising personnel should develop additional pre-
cautions relating to the specic work area and local
safety regulations. If so, place the added precautions in the space provided in this manual.
This tool will provide safe and dependable service if operated in accordance with the instructions given in this manual. Read and understand this manual and any stickers and tags attached to the tool before operation. Failure to do so could result in personal injury or equip­ment damage.
• Do not operate a damaged, improperly adjusted, or in­completely assembled tools.
• To avoid personal injury or equipment damage, all tool repair, maintenance and service must only be performed by authorized and properly trained personnel.
• Do not exceed the rated limits of the tool or use the tool for applications beyond its design capacity.
• Always keep critical tool markings, such as labels and warning stickers legible.
• Always replace parts with replacement parts recom­mended by Stanley Hydraulic Tools.
• Operator must start in a work area without bystanders. The operator must be familiar with all prohibited work areas such as excessive slopes, dangerous terrain con-
ditions, and rail trafc.
• Establish a training program for all operators to ensure safe operation.
• Do not operate the tool unless thoroughly trained or under the supervision of an instructor.
• Always wear safety equipment such as goggles, ear, head protection, and respiratory protection at all times when operating the tool.
• Do not inspect or clean the tool while the battery power source is connected. Accidental arcing can cause seri­ous injury.
• Do not load brazing pins or ceramic rings while the bat­tery power source is connected. Accidental arcing can cause serious injury.
• Do not use the tool while it is connected to a battery charger.
• Ensure battery charging is only done in a dry environ­ment. Charging batteries in the rain or near standing water presents an electrocution hazard. Read the safe­ty and operation instructions provided with the battery charger before using the battery charger.
EP30200 User Manual ◄ 5
EP30200 OPERATION
GENERAL PROTECTION
Store the Electronic Pin Brazing Unit in a place where it is protected from the elements, abrasive dust, and damage.
Use only recommended repair and replacement parts and
materials specied in the Parts List section of this manual.
Use only recommended accessories also specied in the
Parts List section of this manual.
Do not use the Electronic Pin Brazers for applications it was not designed for.
WARNING
Make sure battery charging is only accomplished in a well ventilated room. DO NOT PLACE THE CONTROL BOX ON TOP OF THE BATTERIES. REMOVE THE BATTERY BOX COVER. Battery charging produces explosive gases. A battery explosion can cause serious injuries. Avoid battery explosions by keeping cigarettes, sparks, and ames away from batteries being charged. Always wear safety glasses when working with batteries.
Use the carrying handle to transport the unit from location to location.
CLEANING
Establish a routine to keep the unit as free from dirt as pos­sible – daily, or at each shift change, for example.
Pin Brazers exposed to rain, sand, or grit-laden air should be cleaned prior to each use.
Keep tool labels and stickers legible.
PREOPERATION PROCEDURES
Before putting a new Pin Brazer into initial service, or after an extended period of being unused, perform a visual inspection for bent, broken, cracked, missing or worn components.
INITIAL SETUP AND BATTERY CHARGING
WARNING
1. The three batteries furnished are sealed, maintenance free batteries.
Sealed, maintenance free batteries do not contain cell caps and are already lled with battery acid. They will require charging before use.
NOTICE
Use only battery charger specially made for pin brazing units (36V dc) approved by Stanley.
2. Locate the four battery cables and connect them to the terminals on the batteries and the battery box as shown in
gure 1. Do not replace the lid on the battery box at this time.
+Pos.
-Neg.
Failure to follow the instructions in the battery charger operation manual can result in battery explosion and serious bodily injury. To reduce the risk of battery ex­plosion, read and understand the safety and operation instructions in the battery charger operation manual, the instructions published by the battery manufacturer, and the instructions in this manual before attempting to charge the batteries.
6 ► EP30200 User Manual
Figure 1. Battery cable and terminals
3. Insert the enclosed foam-rubber spacers between each battery and at both ends between the battery and the unit.
4. Connect the battery charger to the grinder outlet on the unit, then to the mains. When removing the charger remove
the main rst, the remove the plug from the unit.
Loading...