WARNING
To reduce the risk of injury, read and understand these safety warnings and instructions before using the tool. Keep these instructions with the tool for future reference. If you have any questions, contact your MAC TOOLS representative or distributor.
600LM Rechargeable INSPECTION LIGHT
© 2018 Mac Tools
TABLE OF CONTENTS
2018.08.20
AEC
受控
Introduction 2
Limited warranty 2 Specications 3 Getting started 4
Warnings 5 Caution 5
Customer service 6
INTRODUCTION
MHL600 is a professional-grade, hands-free light with “Find My Light” function. This light will deliver
efcient, dependable service when used correctly and with care. The manufacturer's instructions must be followed for best performance. Please study this manual before operating the light and understand the safety warnings and instructions. NOTE: Additional safety measures may be required because of your
particular application of the light. Contact your Mac Tools representative or distributor with any questions concerning the light and its use.
Mac Tools North America
505 North Cleveland Avenue
Mac Tools
Westerville, Ohio 43082
800.MACTOOLS
MACTOOLS.COM
LIMITED WARRANTY
We warrant that this light shall be free from manufacturing defects for a period of ONE YEAR from the original purchase date. Our obligation to the original purchaser shall be limited to repairing or replacing, at
our expense (not including shipping charges) a defective light if returned by the original purchaser within
one year from the date of purchase, all incoming shipping charges prepaid. THIS WARRANTY DOES NOT COVER DEFECTS OR DAMAGES TO THE LIGHT (i) after the warranty period expires; (ii) resulting from misuse or abnormal operation; (iii) resulting from a failure to properly maintain or operate the tool; or (iv) resulting from any repair or maintenance services performed by any party other than Mac Tools.
2
MACTOOLS.COM
SPECIFICATIONS
2018.08.20
AEC
受控
LAMP
COB LED
Power button
DOCK
MHL600
WeightModel#
13.4oz / 380g
200° rotating bracket with hidden hook
Lumen
Boost Mode
600
Normal
SPECIFICATIONS
Mode
300
Battery indicator
Run time
Boost Mode
3h30
Call button
Bracket
Normal
Mode
6h30
Charging
time
3h30
Charging
temperature
30° to 113°F /
0° to 45°C
In-charge
power input
8.4W
800.MACTOOLS
Voltage
4.2V max
SPECIFICATIONS
Protection
rating
IP67
Stoage
temperature
23° to 95°F /
-5° to 35°C
Operating
temperature
14° to 140°F /
-10 to 60°C
Swivel
Hook/Magnet
Yes/Yes
3
GETTING STARTED
2018.08.20
AEC
受控
1 - CHANNEL (CHN) SET UP
If you are only using 1 light in a location, the channel is already set and you can skip this step.
If you have multiple "Find My Light" products in the same location, you must set different channels
for each product. To set the channel, nd the dock switches on the back of the light and set each light to a different switch conguration, using only the six combinations shown here,
#1
Please note : Due to the number of available channels, the maximum number of lights in one location is 6. If there is more than one product on the same channel, the location features won't work properly.
2- PLUG IN
Plug the dock into a 120VAC wall receptacle.
By default, the light is in hibernation mode and you'll need to activate
it. After plugging in the dock, wait for the red LED on the dock to start slowly ashing or for the dock to beep (stop it with the button).
Afterward, charge the light for a few seconds to activate it. If the light
doesn’t activate, repeat the process from the beginning.
• Be sure to charge the light every month if used infrequently to ensure battery longevity.
3 - PAIRING
Once the channel is set, you must pair the light to the dock.To do this
• press the dock call button and the light power button for 10 seconds,
simultaneously. Release the button after you hear 3 beeps.
After releasing, if you hear :
- 2 beeps : Pairing succesful
4 - FIND MY LIGHT FUNCTION
When you want to nd a light that has been misplaced, press the dock
call button for 2 seconds. Release when you hear 2 beeps. Afterwards, the light will ash and the light alarm will activate.
Press the power button on the light to turn the alarm off.
#2
- 5 beeps : Pairing failed, repeat this step.
#3
#4
#5
#6
?
5 - OUT OF RANGE FUNCTION
When this function is active, if the light gets too far from the dock, the
connection will break. This will cause the dock and light alarm to activate and the light to ash.
To stop the alerts, press the dock and light buttons or return the light to
• the dock.
By default, the Out of Range Function is deactivated on the light.
- To activate, press the light power button for 5 seconds and release
after you hear 2 short beeps. The function is active if you hear 2 long beeps.
4
OUT OF RANGE
MACTOOLS.COM
- To deactivate, press the light power button for 5 seconds and release
2018.08.20
AEC
受控
after you hear 2 short beeps. The function is deactivated if you hear a further 1 long beep.
The Out of Range function is always active on the dock when the dock is plugged in. If you want to
disable the alarm on the dock, you will need to unplug the dock from the wall.
6 - OUT OF RANGE FUNCTION - POWER (PWR) SETTING
You are able to choose the distance at which the Out of Range Function will activate. There are 4
power settings that can be selected depending on the size of the location where the lights will be
used, as shown below,
Min PWR Mid PWR-1 Mid PWR-2
Max PWR
MIN
MAX
The distance at which the Out of Range function alarms will activate will vary depending on the orientation of the dock and any obstructions between the dock and the light. In an automotive or industrial workplace setting, the average minimum distance to trigger the Out of Range alarms is 100-250ft / 30-75m. To maximize this distance, set the PWR to the maximum setting and mount the dock at against a wall with as few obstructions around the dock as possible. We recommend conducting a physical trial to customize the alarm setting for your workplace.
7 - NORMAL USE OF THE LAMP
Press the power button once for a normal mode, twice for a boost
mode, three times to turn off the lamp.
8 - LOW CHARGE ALERT
When the light has 10 minutes of life remaining, the light will ash and the light alarm will activate.
To stop the alerts, simply return the light to the charging dock to charge it.
Please note : The Find My Light and Out of Range Function will not work once the light dies.
4 5
4 5
4 5
4 5
1 = ON / NORMAL 2 = BOOST 3 = OFF
WARNINGS
The dock is for indoor use only. Do not use in or around water. The lamp can be used outside.
Use only the recommended voltage and frequency requirements.
Keep out of the reach of children
Do not operate dock and lamp with wet hands.
Keep lamp away from hot objects
Do not place near an open ame
Do not crush
CAUTION
This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
800.MACTOOLS