Stanley STFP00020 Instruction Manual

Instruction manual
Manuel d'instructions Manual de'instrucciones
www.StanleyTools.com
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA.
LÉASE ESTE INSTRUCTIVO
STFP00020
Air Compressor
Compresor de aire
Compresseur d’air
Maintenance-free pump
La pompe sans entretien
La bomba sin mantenimiento
Part No. N439650 MAY15 Copyright ©2015 STANLEY TOOLS
2 - ENG
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a practice not related to personal injury which, if not avoided, may result in property damage.
IMPORTANT SAFETY INSTRUCTIONS
This product contains chemicals known to the State of California to cause cancer,
and birth defects or other reproductive harm. Wash hands after handling.
Some dust contains chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm such as asbestos and lead in lead based paint.
To reduce the risk of injury, read the instruction manual.
SAVE THESE INSTRUCTIONS
HAZARD
RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN HOW TO PREVENT IT
• It is normal for electrical contacts within the motor and pressure switch to spark.
• Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors.
• If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.
• If spraying flammable materials, locate compressor at least 20' (6.1 m) away from spray area. An additional length of air hose may be required.
• Store flammable materials in a secure location away from compressor.
• Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.
• Never place objects against or on top of compressor.
• Operate compressor in an open area at least 12" (30.5 cm) away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings.
• Operate compressor in a clean, dry well ventilated area. Do not operate unit in any confined area. Store indoors.
• Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.
• Always remain in attendance with the product when it is operating.
• Always turn off and unplug unit when not in use.
3 - ENG
HAZARD
RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN HOW TO PREVENT IT
• The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon monoxide, toxic vapors, or solid particles from the air tank. Breathing these contaminants can cause serious injury or death.
• Never use air obtained directly from the compressor to supply air for human consumption. The compressor is not equipped with suitable filters and in-line safety equipment for human consumption.
• Exposure to chemicals in dust created by power sanding, sawing, grinding, drilling, and other construction activities may be harmful.
• Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, may contain harmful vapors and poisons.
• Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Always use certified safety equipment: NIOSH/OSHA respiratory protection or properly fit ting face mask designed for use with your specific application.
HAZARD
RISK OF BURSTING
Air Tank: On February 26, 2002, the U.S. Consumer Product Safety Commission published
Release # 02-108 concerning air compressor tank safety: Air compressor receiver tanks do not have an infinite life. Tank life is dependent upon several
factors, some of which include operating conditions, ambient conditions, proper installations, field modifications, and the level of maintenance. The exact effect of these factors on air receiver life is difficult to predict.
If proper maintenance procedures are not followed, internal corrosion to the inner wall of the air receiver tank can cause the air tank to unexpectedly rupture allowing pressurized air to suddenly and forcefully escape, posing risk of injury to consumers.
Your compressor air tank must be removed from service by the end of the year shown on your tank warning label.
The following conditions could lead to a weakening of the air tank, and result in a violent air tank explosion:
WHAT CAN HAPPEN HOW TO PREVENT IT
• Failure to properly drain condensed water from air tank, causing rust and thinning of the steel air tank.
• Drain air tank daily or after each use. If air tank develops a leak, replace it immediately with a new air tank or replace the entire compressor.
• Modifications or attempted repairs to the air tank.
• Never drill into, weld, or make any modifications to the air tank or its attachments. Never attempt to repair a damaged or leaking air tank. Replace with a new air tank.
• Unauthorized modifications to the safety valve or any other components which control air tank pressure.
• The air tank is designed to withstand specific operating pressures. Never make adjustments or parts substitutions to alter the factory set operating pressures.
4 - ENG
ATTACHMENTS & ACCESSORIES:
• Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires, and other inflatables can cause them to explode or fly apart, and could result in serious injury.
• Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use compressor to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
TIRES:
• Over inflation of tires could result in serious injury and property damage.
• Use a tire pressure gauge to check the tires pressure before each use and while inflating tires; see the tire sidewall for the correct tire pressure.
NOTE: Air tanks, compressors and similar
equipment used to inflate tires can fill small tires very rapidly. Adjust pressure regulator on air supply to no more than the rating of the tire pressure. Add air in small increments and frequently use the tire gauge to prevent over inflation.
HAZARD
RISK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN HOW TO PREVENT IT
• Your compressor is powered by electricity. Like any other electrically powered device, if it is not used properly it may cause electric shock.
• Never operate the compressor outdoors when it is raining or in wet conditions.
• Never operate compressor with protective covers removed or damaged.
• Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
• Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electrical codes.
Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death from electrocution. Refer to Grounding Instructions paragraph in the Installation section.
• Make certain that the electrical circuit to which the compressor is connected provides proper electrical grounding, correct voltage and adequate fuse protection.
HAZARD
RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN HOW TO PREVENT IT
• The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury.
• Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields when using the compressor.
• Never point any nozzle or sprayer toward any part of the body or at other people or animals.
• Always turn the compressor off and bleed pressure from the air hose and air tank before attempting maintenance, attaching tools or accessories.
5 - ENG
HAZARD
RISK OF HOT SURFACES
WHAT CAN HAPPEN HOW TO PREVENT IT
• Touching exposed metal such as the compressor head, engine head, engine exhaust or outlet tubes, can result in serious burns.
• Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
• Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
HAZARD
RISK FROM MOVING PARTS
WHAT CAN HAPPEN HOW TO PREVENT IT
• Moving parts such as the pulley, flywheel, and belt can cause serious injury if they come into contact with you or your clothing.
• Never operate the compressor with guards or covers which are damaged or removed.
• Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.
• Air vents may cover moving parts and should be avoided as well.
• Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury.
• Any repairs required on this product should be performed by authorized service center personnel.
HAZARD
RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN HOW TO PREVENT IT
• Unsafe op er a tion of your compressor could lead to se ri ous in jury or death to you or others.
• Review and understand all instructions and warnings in this manual.
• Be come fa mil iar with the op eration and controls of the air compressor.
• Keep operating area clear of all persons, pets, and obstacles.
• Keep chil dren away from the air compressor at all times.
• Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times.
• Never defeat the safety features of this product.
• Equip area of operation with a fire extinguisher.
• Do not op er ate machine with missing, broken, or un au tho rized parts.
• Never stand on the compressor.
6 - ENG
HAZARD
RISK OF FALLING
WHAT CAN HAPPEN HOW TO PREVENT IT
• A portable compressor can fall from a table, workbench, or roof causing damage to the compressor and could result in serious injury or death to the operator.
• Always operate compressor in a stable secure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use additional air hose to reach high locations.
HAZARD
RISK FROM NOISE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Under some conditions and duration of use, noise from this product may contribute to hearing loss.
• Always wear proper hearing protection during use.
SAVE THESE INSTRUCTIONS FOR FUTURE USE
SPECIFICATIONS
Model No. STFP00020
Bore 1.181" (30 mm) Stroke 0.551" (14 mm) Voltage/Hz-Single Phase 120/60 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity 2 Gallon (7.5 liters) Approximate Cut-in Pressure 85 psig Approximate Cut-out Pressure 115 psig SCFM @ 40 psig 0.7 * SCFM @ 90 psig 0.5 * Regulated Pressure Rating (Approximate) 3–115 psig Quick Connect Type 1/4" (6.4 mm) Industrial
*Tested per ISO 1217 Refer to Glossary for abbreviations.
GLOSSARY
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL®, CUL, CULUS, ETL®,
CETL, CETLUS, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain lower level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure.
7 - ENG
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off, protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
DUTY CYCLE
This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.
ASSEMBLY
UNPACKING
Remove unit from carton and discard all packaging.
INSTALLATION
HOW TO SET UP YOUR UNIT
LOCATION OF THE AIR COMPRESSOR
Locate the air compressor in a clean, dry and well ventilated area.
The air compressor should be located at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air.
The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
GROUNDING INSTRUCTIONS (FIG. 1)
RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord
C
A
B
FIG. 1
having a grounding wire with an appropriate grounding plug (A).
1. The cord set and plug (A) with this unit contains a
grounding pin (B). This plug MUST be used with a grounded outlet (C).
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.
2. Make sure the outlet being used has the same
configuration as the grounded plug. DO NOT USE AN ADAPTER. See figure 1.
3. Inspect the plug and cord before each use. Do not use if there are signs of damage.
4. If these grounding instructions are not completely understood, or if in doubt as to whether the
compressor is properly grounded, have the installation checked by a qualified electrician.
RISK OF ELECTRICAL SHOCK. IMPROPER GROUNDING CAN RESULT IN
ELECTRICAL SHOCK. Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should
be installed by a qualified electrician. Repairs to the cord set or plug MUST be made by a qualified electrician.
8 - ENG
EXTENSION CORDS
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product
in good condition
no longer than 50' (15.2 m)
14 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 12 AWG and 10AWG may also be used. DO NOT USE 16 OR 18 AWG.)
Risk of Property Damage. The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.
VOLTAGE AND CIRCUIT PROTECTION
Refer to Specifications for the voltage and minimum branch circuit requirements.
Risk of Overheating. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.
1. Voltage supply to circuit must comply with the National Electrical Code.
2. Circuit is not used to supply any other electrical needs.
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time
delay fuses should be marked "D" in Canada and "T" in the US.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to
change the cord set.
OPERATION
KNOW YOUR AIR COMPRESSOR
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.
DESCRIPTION OF OPERATION (FIG. 2–4)
FIG. 2
D
H
I
E
G
9 - ENG
Become familiar with these controls before operating the unit. On(I)/Off(O) Switch (D): Place this switch in the On (I) position to provide automatic power to the
pressure switch and Off (O) to remove power at the end of each use. Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank
pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.
Safety Valve (H): If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).
Tank Pressure Gauge (I): The tank pressure gauge indicates the reserve air pressure in the tank. Outlet Pressure Gauge (E): The outlet pressure gauge indicates the air pressure available at the outlet
side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.
Regulator (G): Controls the air pressure shown on the outlet pressure gauge. Turn regulator knob clockwise to increase pressure and counterclockwise to decrease pressure.
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Drain Valve (K): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.
K
FIG. 3 FIG. 4
F
Check Valve (not shown): When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.
Motor Overload Protector (not shown): The motor has a thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart:
1. Set the On/Off switch to "Off" and unplug unit.
2. Allow the motor to cool.
3. Plug the power cord into the correct branch circuit receptacle.
4. Set the Auto/Off switch to "On" position. Motor Fuse Protector (not shown): The motor is provided with a fuse protector which may cause the
motor to shut off if motor current is too high. If the motor does not operate, follow the instructions under Motor Overload Protector. If the motor fails to restart after following these instructions, return the unit to a service center to have the fuse protector replaced. The fuse protector is not a customer serviceable part.
Quick-Connect Body (F): The quick connect body accepts industrial quick connect plugs.
HOW TO USE YOUR UNIT (FIG. 2)
HOW TO STOP
1. Set the On/Off switch (D) to "Off".
2. Unplug unit when not in use.
10 - ENG
BEFORE STARTING
Do not operate this unit until you read this instruction manual for safety,
operation and maintenance instructions. BEFORE EACH START-UP
1. Set the On/Off switch (D) to "Off".
2.
Plug the power cord into the correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the Installation section of this manual.)
3. Turn the regulator knob (G) counterclockwise to set the outlet pressure to zero.
4. Attach hose and accessories.
Risk of unsafe operation. Firmly grasp air hose in hand when installing or
disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn accessories.
NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick
connect body (F).
Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
Risk of property damage. Compressed air from the unit may contain wa ter condensation and oil mist. Do not spray un fil tered air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the in struc tions for the air tools and accessories.
HOW TO START
1. Set the On/Off switch (D) to "On" and allow tank pressure to build. Motor will stop when tank
pressure reaches "cut-out" pressure.
2. Turn regulator knob (G) clockwise to increase pressure and stop when desired pressure is reached.
Risk of unsafe operation. If any unusual noise or vibration is noticed, stop the
compressor immediately and have it checked by a trained service technician.
The compressor is ready for use.
MAINTENANCE
CUSTOMER RESPONSIBILITIES
Before each use Daily or after
each use
See tank warning label
Check Safety Valve X Drain Tank X Remove tank
from service
X
1
1- For more information,
call our Customer Care Center at 1-800-262-2161
Risk of unsafe operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
NOTE: See Operation section for the location of controls.
TO CHECK SAFETY VALVE (FIG. 2)
Risk of Bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion.
11 - ENG
Risk from Flying Objects. Always wear certified safety equipment: ANSI Z87.1
eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve (H) to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
TO DRAIN TANK (FIG. 2, 3)
Risk of Unsafe Operation. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use ANSI Z87.1 eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up into face.
Risk from noise. Always wear proper hearing protection during use. Under some conditions and duration of use, noise from this product may contribute to hearing loss.
NOTE: All compressed air systems generate condensate that accumulates in any drain point (e.g., tanks, filter,
aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.
Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
Risk of Property Damage. Drain water from air tank may contain oil and rust which
can cause stains.
1. Set the On/Off switch (D) to "Off".
2. Turn the regulator knob (G) counterclockwise to set the outlet pressure to zero.
3. Remove the air tool or accessory.
4. Place a suitable container under the drain valve to catch discharge.
5. Pull ring on safety valve (H) allowing air to bleed from the tank until tank pressure is approximately
20 psi. Release safety valve ring.
6. Drain water from air tank by opening drain valve (K) on bottom of tank.
7. After the water has been drained, close the drain valve. The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then
reinstalled.
SERVICE AND ADJUSTMENTS
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.
Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
STORAGE
Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform scheduled maintenance as
necessary.
2. Drain water from air tank. See To Drain Tank under Maintenance.
Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
3. Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind
air hose loosely around the compressor handle. Wrap electrical cord onto the cord wrap.
4. Store the air compressor in a clean and dry location.
12 - ENG
SERVICE
REPLACEMENT PARTS
Use only identical replacement parts. For a parts list or to order parts, visit our service website at www.stanleytools.com. You can also order parts from your nearest STANLEY Factory Service Center or STANLEY Authorized Warranty Service Center. Or, you can call our Customer Care Center at 1-800-262-2161.
SERVICE AND REPAIRS
All quality tools will eventually require servicing and/or replacement of parts. For information about STANLEY, its factory service centers or authorized warranty service centers, visit our website at www.stanleytools.com or call our Customer Care Center at 1-800-262-2161. All repairs made by our service centers are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by others.
You can also write to us for information at STANLEY, 4825 Highway 45 North, Jackson, Tennessee 38305
-Attention: Product Service. Be sure to include all of the information shown on the nameplate of your tool (model number, type, serial number, etc.).
ACCESSORIES
Since accessories, other than those offered by STANLEY, have not been tested with this product, use of such accessories with this tool could be hazardous. To reduce the risk of injury, only STANLEY recommended accessories should be used with this product.
A complete line of accessories is available from your STANLEY Factory Service Center or a STANLEY Authorized Warranty Service Center. Please visit our Web Site www.stanleytools.com for a catalog or for the name of your nearest supplier.
TROUBLESHOOTING
Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
PROBLEM CAUSE CORRECTION
Excessive tank pressure
- safety valve pops off.
Pressure switch does not shut off motor when compressor reaches "cut-out" pressure.
Move On/Off switch to the "Off" position, if the outfit does not shut off
contact a Trained Service Technician. Pressure switch "cut­out" too high.
Contact a Trained Service Technician.
Air leaks at fittings. Tube fittings are not
tight enough.
Tighten fittings where air can be heard
escaping. Check fittings with soapy
water solution. Do Not Overtighten.
Air leaks in air tank or at air tank welds.
Defective air tank. Air tank must be replaced.
Do not repair the leak.
Risk bursting. Do not drill into, weld or otherwise modify air tank or it will weaken. The tank can rupture or explode.
Air leaks between head and valve plate.
Leaking seal. Contact a Trained Service Technician.
13 - ENG
PROBLEM CAUSE CORRECTION
Air leak from safety valve.
Possible defect in safety valve. Operate safety valve manually
by pulling on ring. If valve still leaks, it should be replaced.
Knocking Noise. Possible defect in safety valve. Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced. Pressure reading on the regulated pressure gauge drops when an accessory is used.
It is normal for "some" pressure drop to occur.
If there is an excessive amount of pressure
drop when the accessory is used, adjust
the regulator following the instructions
in the Description of Operation
paragraph in the Operation Section.
NOTE: Adjust the regulated
pressure under flow conditions
(while accessory is being used). Compressor is not supplying enough air to operate accessories.
Prolonged excessive use of air. Decrease amount of air usage. Compressor is not large enough for air requirement.
Check the accessory air requirement. If
it is higher than the SCFM or pressure
supplied by your air compressor,
you need a larger compressor.
Hole in hose. Check and replace if required. Check valve restricted. Have checked by a Trained
Service Technician.
Air leaks. Tighten fittings. Regulator knob has continuous air leak.
Damaged regulator. Replace.
Regulator will not shut off air outlet.
Damaged regulator. Replace.
Motor will not run. Fuse blown, circuit
breaker tripped.
Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. You should use a time delay fuse. Check for low voltage problem. Check the extension cord. Disconnect the other electrical appliances from circuit or operate the
compressor on its own branch circuit. Extension cord is wrong length or gauge.
Check the extension cord.
Loose electrical connections. Check wiring connection
inside terminal box. Faulty motor. Have checked by a Trained
Service Technician. Motor overload protection switch has tripped.
Refer to Motor Overload Protection
under Operation. If motor overload
protection trips frequently, contact
a Trained Service Technician.
14 - ENG
FULL ONE YEAR WARRANTY
STANLEY industrial tools are warranted for one year from date of purchase. We will repair, without
charge, any defects due to faulty materials or workmanship. For warranty repair information, call 1-800­262-2161. This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces.
LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained either in the packaging, call the local company or see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call 1-800-262-2161 for a free replacement.
Loading...
+ 30 hidden pages