ST-602-WS-E / ST-603-WS-E
Workshop Electric Fan Heater
821000400-13

ENGLISH
Read The Instruction manual: When this symbol is marked on a product, it means that the
instruction manual must be read.
In order to avoid overheating, do not cover the heater.
© 2013, Pinnacle Products International, Inc.

ST-602-WS-E
4
6
5
7
1. POWER CABLE
2. FUNCTION SELECTOR
3. HANDLE
4. THERMOSTAT KNOB
5. CAUTION LIGHT
6. POWER LIGHT
7. FRONT GUARD
1. CORDON D’ALIMENTATION
2. SÉLECTEUR DE FONCTIONS
3. POIGNÉE
4. SELECTEUR DE THERMOSTAT
5. ATTENTION LA LUMIÉRE
6. PUISSANCE DE LA LAMPE
7. PROTECTION AVANT
1. ELEKTRICITEITSSNOER
2. FUNCTIEKEUZEKNOP
3. HANDVANT
4. THERMOSTAATKNOP
5. LET OP LICHT
6. LAMPJE
7. BESCHERMING VOORZIJDE
1. CABLE DE ALIMENTACIÓN
2. SELECTOR DE FUNCIÓN
3. ASA
4. BOTÓN DEL TERMOSTATO
5. ATENCIÓN LUZ
6. POTENCIA LUZ
7. PROTECTOR FRONTAL
1. Power Cable
2. Function Selector
3. Handle
4. Thermostat Knob
5. Caution Light
6. Power Light
7. Front Guard
2
1.
NÄTSLADD
2. FUNKTIONSVÄLJARE
3. HANDTAG
4.
TERMOSTATVRED
5. FÖRSIKTIGHET LJUS
6. STRÖMLAMPA
7. FRÄMRE SKYDD
1.
STRØMKABEL
2. FUNCTION SELECTOR
HÅNDTAK
3.
4.
TERMOSTATKNAPP
5. FORSIKTIG LYS
6. LAMPEN
7. FRONTVERN
3
1
1.
WTYCZKA
2. WYBÓR FUNKCJI
UCHWYT
3.
4.
TERMOSTAT
5. KONTROLKA OSTRZEGA
6. KONTROLKA ZASILANIA
7. OSŁONA PRZEDNIA
ST-603-WS-E
1. POWER CABLE
2. FUNCTION SELECTOR
3. HANDLE
4. THERMOSTAT KNOB
5. CAUTION LIGHT
6. POWER LIGHT
7. FRONT GUARD
8. HEATER STAND
1. CORDON D’ALIMENTATION
2. SÉLECTEUR DE FONCTIONS
3. POIGNÉE
4. SELECTEUR DE THERMOSTAT
5. ATTENTION LA LUMIÉRE
6. PUISSANCE DE LA LAMPE
7. PROTECTION AVANT
8. SUPPORT DE L'APPAREIL
DE CHAUFFAGE
3
2
1
1. ELEKTRICITEITSSNOER
2. FUNCTIEKEUZEKNOP
3. HANDVANT
4. THERMOSTAATKNOP
5. LET OP LICHT
6. LAMPJE
7. BESCHERMING VOORZIJDE
8. KACHELVOET
1. CABLE DE ALIMENTACIÓN
2. SELECTOR DE FUNCIÓN
3. ASA
4. BOTÓN DEL TERMOSTATO
5. ATENCIÓN LUZ
6. POTENCIA LUZ
7. PROTECTOR FRONTAL
8. SOPORTE DEL CALEFACTOR
1. Power Cable
2. Function Selector
3. Handle
4. Thermostat Knob
5. Caution Light
6. Power Light
7. Front Guard
8. Heater Stand
1.
2. FUNKTIONSVÄLJARE
3. HANDTAG
4.
5. FÖRSIKTIGHET LJUS
6. STRÖMLAMPA
7. FRÄMRE SKYDD
8. STÄLL FÖR VÄRMEELEMENT
1.
2. FUNCTION SELECTOR
3.
4.
5. FORSIKTIG LYS
6. LAMPEN
7. FRONTVERN
8. APPARATSTATIV
6
NÄTSLADD
TERMOSTATVRED
STRØMKABEL
HÅNDTAK
TERMOSTATKNAPP
4
5
7
8
1.
WTYCZKA
2. WYBÓR FUNKCJI
3.
UCHWYT
4.
TERMOSTAT
5. KONTROLKA OSTRZEGA
6. KONTROLKA ZASILANIA
7. OSŁONA PRZEDNIA
8. STOJAK GRZEJNIKA
© 2013, Pinnacle Products International, Inc.

SPECIFICATIONS
6SHFL¿FDWLRQVVXEMHFWWRFKDQJHZLWKRXWQRWLFH
ST-602-WS-E ST-603-WS-E
THERMAL POWER (kw)
2.0 2.0
THERMAL POWER (Btu) 6,828 6,828
AIR FLOW (CMH) 161 85
HEATING AREA (cu. m) 6 6
POWER (Volt / Hz) 220V - 240V / 50Hz 220V - 240V / 50Hz
HEAT SETTINGS 2 2
INGRESS PROTECTION RATING (IP) IP44 IP44
© 2013, Pinnacle Products International, Inc.

NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Safety Features
AUTOMATIC TIP-OVER SAFETY SWITCH
The tip-over switch is located inside the cabinet
housing. The tip-over safety switch allows the unit
to operate only when the heater is placed on a
level surface. If the heater is tipped or tilted while in
operation, it will automatically shut off.
AUTOMATIC OVERHEAT SAFETY CONTROL
This heater is equipped with safety internal heat
limiting thermostat and overheat protection circuit.
When a potential overheat temperature is reached,
the system will automatically shut the heater off
and turn the alert light on.
ALERT INDICATOR LIGHT
The alert light will turn on when the heater internal
temperature rises to an unsafe level. If this
situation occurs, make sure the heater is on a level
surface and clear of all obstructions. Unplug the
heater and allow it to “cool down” before restarting.
Operation
Position the fan heater so that it stands upright
on a firm surface and at a safe distance from wet
environments and flammable objects.
In order to protect the enclosure, don’t splash
water onto the heater, and never use a solvent like
gasoline, isoamyl acetate, toluene, etc. to clean the
heater.
When you store the heater, let it cool down first
and, keep it dry. Then cover it with a plastic bag,
put it in the packing box and store it in a dry,
ventilated place.
1000
0
2000
–
Thermostat
Function
Selector
+
Connect the fan heater to the electrical power.
Set the thermostat dial to the maximum
temperature.
The fan heater will switch on when the function
selector dial is set to one of the two power settings.
Once the room reaches the desired temperature,
turn the thermostat dial back until heating element
turns off. The fan will still continue to run. The
thermostat is now set at your desired temperature,
and the heater will continue to maintain a constant
temperature.
Cleaning and Maintenance
Before cleaning the appliance, disconnect it from
the outlet and let it cool down.
The enclosure is easy to get dirty. Wipe it often
with a soft sponge. For very dirty parts, wipe with a
sponge dipped in < 50°C water and mild detergent,
then dry the heater enclosure with a clean cloth.
Be careful not to let the water enter the inside of
the appliance
Clean the coupler, dry and pack it in a plastic bag.
Figure 1: ST-602-WS-E
–
Thermostat
Figure 2: ST-603-WS-E
+
Caution LightPower Light
2000
1000
O
Function
Selector
Caution LightPower Light
© 2013, Pinnacle Products International, Inc.

NEVER LEAVE HEATER UNATTENDED WHILE
CONNECTED TO A POWER SOURCE
Plug Replacement
WARNING
RISK OF ELECTRIC SHOCK! DISCONNECT FROM POWER BEFORE MAINTENANCE.
NOTE: This section only applies to heaters sold or used in Great Britain.
This appliance is supplied with a BS1363 3 pin
SOXJ¿WWHGZLWKDIXVH6KRXOGWKHIXVHUHTXLUH
replacement, it must be replaced with a fuse
with the proper amp rating. (see Technical
6SHFL¿FDWLRQVSDJHDQGDSSURYHGWR%6
In the event the mains plug has to be removed/
replaced for any reason, please note:
IMPORTANT: The wires in the mains lead are
colored in accordance with the following code:
Blue – Neutral Brown – Live
Green/Yellow – Earth
As the colors of the wires in the mains lead of this
appliance may not correspond with the colored
markings identifying the terminals in your plug,
proceed as follows:
The blue wire must be connected to the terminal
marked with an N or colored black. The brown
wire must be connected to the terminal marked
with an L or colored red. The green/ yellow wire
must be connected to the earthing terminal which
is marked with an E or with the earth symbol.
WARNING
Never connect live or neutral
wires to the earth terminal of
the plug.
127(,IDPRXOGHGSOXJLV¿WWHGDQGKDVWR
be removed take great care in disposing of the
plug and severed cable, it must be destroyed to
prevent engaging into a socket.
Figure 3
Plug Replacement Wiring Diagram
GREEN / YELLOW
Earth
BLUE
Neutral
CORD CLAMP
BROWN
Live
FUSE
13 Amps
© 2013, Pinnacle Products International, Inc.