Installation Addendum for Stanley Omnilock 45HOM Extreme Weatherized Locks
Connecting cables
Module bracket
Wire inlet
Figure 1 Inside circuit module
Escutcheon mounting screws
Grounding
wire
45HOM Extreme Weatherized Mortise Locks
This addendum begins at step 11 of Installation Instructions for Stanley Omnilock 45HOM Mortise Locks T83312.
1 Insert the escutcheon standoffs into the predrilled holes. 2 Thread connecting cables, motor wire and grounding wire through the
door cable hole. Use screws and washers to attach the escutcheon from the inside of the door. See Figure 1.
Note: Ensure that no wires are pinched when attaching the escutcheon to the door.
3 Thread the connecting cables motor wire and grounding wire through the
module bracket wire inlet. 4 Attach the module bracket to the door with the proper mounting screws. 5 Connect the wires and batteries as shown in Figure 2. 6 Secure the module cover with the security screws provided. See Figure 3. 7 Continue with step 14 of the Installation Instructions for Stanley Omnilock
45HOM Mortise Locks T83312 to complete the installation.
Security screws
12 Pin
Connector
Wire inlet
Cover grounding wire
Figure 2 Wire connections to circuit module
T83317/Rev A 0000000 ER-7991-12 Jan 2010
Connector
Grounding
a Product Group of Stanley Security Solutions, Inc.
10 Pin
wire
Figure 3 Inside view of weatherized model
Stanley Omnilock
Page 2
189 mm
7 29/64 in
1/8 in
1/8 in
3mm
J
J
3mm
3/4 in
K
19 mm
Through hole
1/8 in
1/8 in
3mm
J
J
3mm
3/16 in
3/16 in
F
5mm
5mm
F
Through hole
Through hole
1/8 in
1/8 in
3mm
H
H
3mm
1/2 in
13 mm
B
of lock
Horizontal centerline
3/8 in
D
10 mm
7/8 in
23 mm
C
Horizontal centerline
3/8 in
10 mm
D
of lever
Vertical centerline
of lever
use copies or facsimiles.
Align to vertical centerline
Hole Descriptions
TV model only
B Thumb turn (1)
printed templates. Do not
Inside Door
Cables
Weatherized module bolts (4)
Trim mounting (2)
Module bolt (2)
C Lever (1)
F
D
Thumb turn mounting screws (2)
H
TV model only
J
K
To ensure accurate door preparation, use only factory-
Loading...