Stanley Installation And Operating Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
K1700 & K2300
Wood Pellet Boiler Stove
Installation and Operating Instructions
Read these instructions carefully before installing, using and servicing the stove.
Table of Contents
1 SETTING THE LANGUAGE FOR THE FIRST TIME. ................................................................................................................. 3
2 STANLEY PELLET STOVE WARRANTY .................................................................................................................................. 4
6 INSTALLATION OF THE BOILER PELLET STOVE .................................................................................................................... 9
9 USE OF THE BOILER PELLET STOVE ................................................................................................................................... 14
9.2.1 Menu ................................................................................................................................................................. 16
9.2.2 Water temperature ............................................................................................................................................. 16
Remove side covers ........................................................................................................................................ 23
Pellet reservoir lid .......................................................................................................................................... 24
15 PERFORMANCE GRAPHS FOR THE UPSO 15-55 CIAO CIRCULATING PUMP ...................................................................... 33
FIGURE 8 – PERFORMANCE GRAPHS FOR THE CIRCULATING PUMP........................................................................................... 33
16 LIFE CYCLE OF A BOILER PELLET STOVE ............................................................................................................................ 33
Thank you for purchasing a Waterford Stanley Wood pellet Stove.
Please read this manual carefully and retain it for future reference.
These products fulfil the requirements of the Construction Products Regulation and have
been approved with the CE conformity mark;
The Boiler pellet stoves are manufactured in compliance with the EN 14785:2008 Standards
WATERFORD STANLEY bears no responsibility for any damage to the stove if it is installed
by non-qualified personnel;
WATERFORD STANLEY is not responsible for any damage to stoves not installed and used
in compliance to the instructions included in this manual;
All local regulations, national and European standards, must be observed when installing,
operating and servicing the stove;
Whenever you need assistance, you should contact your stove’s supplier or installer. You must
have the wood pellet stove serial number located on the identification plate.
The product must be commissioned by a Waterford Stanley approved service engineer.
1 Setting the Language for the first time.
To set the Language to English on the controller.
Press the menu button until “ set” is displayed beside the menu button.
Press the “ +” button 4 times , display shows “configura.......”.
Press the set button twice until abbreviation for languages in the top and centre of the screen.
Press the “ +” button until abbreviation “EN” is displayed.
Press the Menu button to set the language to English.
3
·
Electrical
components under normal operation.
WS Service Department.
review.
2 STANLEY PELLET STOVE WARRANTY
CONDITIONS OF WARRANTY
Your Stanley pellet stove is guaranteed against any part that fails (under normal operating conditions) as
detailed in the following table with timelines specified from the date of installation of the appliance. If the
stove is not installed within six months of date of purchase, the warranty will commence six months from
the date of purchase.
Warranty
Parts Covered (Parts & Labour unless Stated)
Period
Up to 1
Year
· Refractory materials (supply only)
· Rope seals, glass seals and cement seals.
· Surface Finish on Seno models.
· Grates and fire bars.
· Ceramic glass is covered for Thermal breakage (supply only).
· Rust (if reported before installation)
· Aesthetic Damage (provided reported on date of receipt)
Up to 2
Years
Up to 3
Years
·All external casings & enamel finishes (excluding impact damage or
damage caused by overfiring). Pictures of damage must be submitted to
·Boiler - A Leaking Boiler Report must be conducted by an Authorised
Stanley Service Engineer and submitted to WS Service Department for
All warranty claims must be reported to the Waterford Stanley Service Department and must be submitted with the product serial
number (located on the data plaque at the rear of the product), date of purchase, proof of purchase (if requested) and details of the
specific nature of the problem.
The warranty is given only to the original consumer/purchaser only and is non- transferable. The appliance must be installed by a
suitable qualified person and installed as per the requirements of the manual. Failure to comply with the Installation requirements
or Building Regulations will void your warranty. Waterford Stanley reserve the right to replace any part due to manufacturing
defect that fails within the warranty period under the terms of the warranty. The stove must be used for normal domestic purposes
only and in accordance with manufacturer's operation instructions.
LIMITS OF LIABILITY
The warranty does not cover:
· Special, incidental or consequential damages, injury to persons or Property, or any other consequential loss.
· Any issue caused by negligence, misuse, abuse or circumstances beyond Waterford Stanley’s control.
· Any issue with wear and tear, modification, alteration, or servicing by anyone other than an authorized service engineer.
· Installation and operational related problems such as draught related issues external to the stove, inadequate venting or
ventilation, excessive flue offsets, negative air pressure caused by insufficient burning of improper fuel.
· Damage caused to the stove while in transit.
· Discolouration due to over firing, damage caused by impact, damage to baffles caused by over firing and fading of
surface finish on casting.
· Stress fractures on bricks.
· Rust on cast iron parts unless reported prior to stove being installed.
· Aesthetic damage, rust & missing parts on stoves purchased off display.
· Electrical components where voltage variations are in excess of 10% of nominal 230V
Note: Adequate clearance must be maintained around the appliance to ensure the ease of part removal in the possible event of
their damage/failure. Waterford Stanley are not responsible for any costs incurred in the removal of items installed in the vicinity
of the appliance that must be moved to facilitate a part replacement.
4
3 Package content
- Boiler pellet stove model K1700 & K2300
- Side covers, top front cover and bottom front cover
- Instruction Manual &Power cable
3.1 Unpacking the free-standing fire
When unpacking the stove, please refer to the illustrations below. First remove the retractable bag containing the cardboard box
(Figure 1-a). Then pull the cardboard box out (Figure 1-b) by lifting it and remove the bag containing the free-s t anding
fire stove (Figure 1-c) and the Styrofoam plates. Finally, unscrew the four parts securing the stove to the wood pallet (Figure 1d and -e).
a) b) c)
d) e)
Figure 1 – Unpacking the free-standing fire stove
4 Safety precautions
Waterford Stanley is not liable for any damages to the stove if the specified precautions, warnings and operating procedures are
not followed.
Stoves manufactured by Waterford Stanley are easy to operate and special attention was given to their components in order to
protect users and installers against accidental damages.
The stoves must only be installed by an authorised engineer, who should supply the client with a relevant statement of conformity
and who shall be liable for the final installation and consequent product good operating conditions.
This stove must be used according to its intended use as specified by the manufacturer. The manufacturer is excluded from all
liability, by contract or by tort, caused by injury to people, animals or property arising from misuse or faulty installation or servicing.
After removing the packaging, verify the contents to check their integrity and completeness. If the content of the package
fails to correspond to that indicated in point 1, contact the salesperson from whom you purchased the stove.
All the stove's components guarantee its operation and energy efficiency and should only be replaced with original parts provided
by an authorised technical assistance centre.
The stove must be serviced at least once a year by the installation engineer. This manual is provided with the
product. Please keep it close to the stove.
5
4.1 For your safety, we recommend that:
· Make sure you fully read and understand this instruction manual before using the boiler pellet stove as a biomass heating stove.
·
· Make sure that the hydronic/ plumbing circuit was correctly assembled and connected to the water supply before turning on the
boiler pellet stove.
·
· The boiler pellet stove is not intended for use by children or persons with reduced physical, sensory or mental capabilities,
·
· or lack of experience or knowledge, unless they are under supervision or have been instructed concerning the use of the stove.
·
· Do not touch the stove when barefoot or if any part of your body is wet or humid;
·
· Do not tamper with safety or adjustment features without the manufacturer's authorization;
·
· Do not cover or reduce the size of the vents at the installation area;
·
· The boiler pellet stove requires a clear space around the stove for proper combustion, so possible air tightness of the location or
any existing air extraction sources in the room may prevent the stove proper operation;
· The existence of vents is a requisite for proper combustion;
·
· Do not leave the packing materials near children;
·
· During normal operation, Free Standing Fire stove's door must not be opened;
·
· Some parts of the stove may overheat during normal operation, so avoid direct contact with parts such as the door handle and
glass;
·
· Check the existence of any obstructions on the fume duct before turning on the stove after a long period of inactivity;
·
· This boiler pellet stove is intended for residential use in protected areas. Safety systems may turn off the stove. If this occurs,
contact the technical assistance. In any circumstances should you attempt to interfere with the safety systems;
·
· The boiler pellet stove is a biomass heating stove equipped with an electric fume extractor. The occurrence of any power failure
during its use may prevent fume extraction and the room will be filled with smoke. For this reason, you should have a natural
fume extraction system, like a chimney, available;
·
· During operation, NEVER turn off the free-s ta n din g fire stove by disconnecting the electric plug. The fume extractor on
the free-standing pellet fire stove is electric so disconnecting the power plug will prevent the extraction of combustion fumes;
·
· Your stove must be disconnected from the mains for servicing. Before doing this, the stove must be totally cooled down (if
operating before);
·
· Never touch the interior of the stove without disconnecting it from the power mains;
·
· The maximum temperature of the water that can be set by the user (water set-point temperature) is 85°C. In the event of a
temperature of 90ºC being reached, the boiler pellet stove automatically disconnects, and the respective alarm is activated.
6
5 Technical specifications
45
50
66
12 12
22 22
Table 1 – Technical specifications
FEATURES
Weight
Height
Width
Depth
Diameter of the fume discharge pipe
Reservoir capacity
Maximum heating capacity
Maximum overall thermal power (fire
Minimum thermal power (fire insert/boiler)
Minimum fuel consumption
Maximum fuel consumption
Rated electrical current
Electric power at start-up (<10 min.)
Rated voltage
Nominal frequency
Thermal yield at rated thermal power
K1700 K2300
202
1150
600
655
100
30
384
14,2 / 3 18,8 / 3,3
4,3 / 0,8 4,3 / 0,8
1,1
3,9
134
434
230
50
91,1
219
1210
665
730
100
520
1,1
5,1
134
434
230
89,2
Stoves
Kg
mm
mm
mm
mm
Kg
m³
kW
kW
Kg/h
Kg/h
W
W
V
Hz
%
Thermal yield at reduced thermal power
Combustion gas flow (max.)
Combustion gas flow (min.)
Max. gas temperature
Min. gas temperature
CO emissions at rated thermal power
CO emissions at reduced thermal power
Draught in the chimney
Stove water volume
Sound level max.
93,8
14,8
6,9
128
66
0,02
0,02
49,1
93,8
%
18,8
6,9
153
0,02
0,024
49,1
g/s
g/s
ºC
ºC
%
%
Pa
W
dB(A)
7
Tests performed using wood pellets with a heating capacity of 4.9 kWh/kg.
The above information was obtained during product homologation tests performed at independent laboratories
accredited for pellet stove tests.
Front Rear
Side
Top
Front Rear
Figure 3 – Dimensions of the K2300
Figure 2 – Dimensions of the K1700
Side
Top
Figure 5 – Hydraulic connections of the K1700 Figure 6 – Hydraulic connections of the K2300
8
6 Installation of the boiler pellet stove
Before installing, please perform the following steps:
· Upon receipt, check the product for completeness and to determine that is does not show any damage signs. Any damages
or defects should be checked before the stove is installed.
· The stove is equipped with four adjustable height feet at the base which allow for a simple adjustment when installed on a
unlevel surface.
· Remove the instruction manual from the package and hand it over to the client.
· Connect a 100mm diameter flue between the combustion gas output and the outgoing fume extraction duct of the building
(e.g. chimney) – check location diagrams under no. 4.
· If a pipe is used for combustion air inlet from the outside, it shall be no longer than 60cm horizontally or present offsets (such
as bends);
· Perform the hydronic installation
· Connect the 230VAC power cable to a grounded socket.
· The surface of the stove where the hot air outlet is located must be facing the area to be heated.
Figure 7 – Adjustable feet
9
6.1 Assembly of removable parts
After the installation, the stove should be fitted with the removable covers.
- Top front cover
To install the top front cover, place it over the stove (Figure-8a) and then tighten the screws that secure it to the top panel of
the stove (Figure 8b).
8a) 8b)
- Bottom front cover
The bottom front cover can be assembled by removing the screws located on the bottom part of the stove. Then place the part in
the appropriate position (Figure 9-a) and replace and tighten the screws again (Figure 9-b)
Figure 13 – Assembly of the top front cover
9a) 9b)
Figure 14 – Assembly of the bottom front cover
- Side covers
To install the stove's side covers position the covers and insert them as illustrated, onto the existing supports.
Figure 10 – Assembly of side covers
10
7 Installation requirements
The minimum distance between the free-standing pellet fire stove and particularly flammable surfaces is specified in
Figure 11.
The top of the stove must be at least 100cm separated from the ceiling, especially in rooms with ceilings consisting of
flammable materials.
The base supporting the stove cannot be made of combustible material (e.g. carpet), so make sure you use an adequate
protection.
a) b)
Figure 11 – Clearances to combustibles: a) plan view of the stove's installation;
b) side view of the stove's installation
7.1 Installation of ducts and fume extraction systems:
· The exhaust pipe must have been designed for this purpose, in compliance to the location requirements and in accordance
with any applicable regulations.
·Important! An inspection-T with an airtight lid must be attached to the exhaust pipe of the stove to allow the regular
inspection of the system or discharge of heavy dust and condensates. As indicated in Figure 15, the exhaust pipe must be
assembled to allow cleaning and maintenance of the pipe by inserting inspection points.
· Under normal operating conditions, the combustion gas flow should create a draught of 12 Pa one meter above the chimney
neck.
· The stove must be installed in a shared chimney
· Pipes outside the heated area must be suitably insulated
7.2 Installation without a chimney
The installation of the boiler pellet stove without a chimney should be performed as illustrated in Figure 16, with 100 mm diameter
flue pipe up to the Tee piece for the boiler model) directly outside and over the roof.
Double-walled stainless- s teel insulated pipes must be used and properly fastened to avoid condensation.
A T-tube must be installed at the base of the pipe to allow periodic inspections and annual maintenance, as illustrated in
Figure 16.
11
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.