Owner’s Manual
This manual contains important safety instructions for gasoline generator models: G2250S, G3250S
that should be followed during operation and maintenance of the generator.
READ SAFETY WARNINGS AND OPERATING INSTRUCTIONS CAREFULLY, SAVE THESE INSTRUCTIONS.
Contents:
2-3 STANLEY Product Lines
3 Missing Parts Request Form
4 Warnings
5 –6 Warnings and Specifications
7-8 Component Identification
9 Assembly and Optional Wheel Kit Installation
10 Controls
10 –11 Operating the Generator
12-13 Maintenance, Transporting and Storage
14-15 Troubleshooting
16 Warranty and Service
or go to www.portablegenerator911.com or www.GXiOutdoorPower.com
Have the following information ready when you call us:
Date of Purchase: _______________________
Location of Purchase: _______________________
Serial #: _______________________
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
No part of this publication can be printed or copied without written permission.
DO NOT RETURN THIS GENERATOR
TO THE STORE
HAVE QUESTIONS OR NEED HELP?
call our help-line: [1] 919-550-3259
1 of 16 Rev. 7/2010

STANLEY Product Lines
Models: G2250S & G3250S
For more information or where to purchase STANLEY outdoor power equipment, visit
us at: www.GXiOutdoorPower.com
Walk Behind Turf and Brush Mowers
36” Brush Mower
HONDA GXV 530 V-twin engine
Hydro Drive
Convertible deck— easily converts to a finish mower.
Zero-Turn Commercial Mowers
54” and 62”
HONDA and Robin Subaru engines
Hydro Drive
100” Tow Behind Mower
Model: 100TS
Commercial duty STANLEY tow behind mower
HONDA GXV 530 V-twin engine cuts up to 100 inches.
52 in. brush cut or a 52 in. finish cut mower with wings up.
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
No part of this publication can be printed or copied without written permission.
Commercial Walk Behind Mowers
36” and 54” deck
HONDA GXV 530 V-twin engine
Belt drive or Hydro Drive
2 of 16 Rev. 7/2010

STANLEY Product Lines
Electric Pressure Washers
1450 psi to 1800 psi electric pressure washers
20 ft of high pressure hose and 35 ft. cord with GFCI protection
Sleek and unique, high quality, stainless steel finish
13 Amps, 120V
Auto-stop shut off system prolongs pump life
Generator Cord Accessories
240V, 10/4, heavy duty extension cords with L14-30 connectors at each end.
Reduces harmful voltage drops experienced when using smaller gauge cords.
Available in 15’ and 25’ lengths
Can be combined to reach the desired length.
Models: G2250S & G3250S
Missing Parts Request Form
Please indicate the part that you are missing:
Hardware bag
Other
Date of purchase
Model #:
G2250S
G3250S
Serial #:
Comments:
All Weather Storm Generators
Patent pending, all weather design
Safe to operate in rainy, wet conditions
Commercial duty engine.
No maintenance, copper, brushless alternator.
Name
Address
Email
Phone
IMPORTANT: Please include a copy your receipt. Without a receipt, your order will be delayed.
E-mail : customerservice@gxioutdoorpower.com
Fax: 1-919-550-3277
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
No part of this publication can be printed or copied without written permission.
3 of 16 Rev. 7/2010

WARNINGS
Models: G2250S & G3250S
This owner’s manual is considered a permanent part of the generator
and should remain with the generator if resold. The information and
specifications included in this publication were in effect at the time of
approval for printing.
GXi Outdoor Power, LLC, reserves the right to discontinue or change
specifications or design at any time without notice and without incurring any obligation whatever. No part of this publication may be reproduced without written permission.
EMISSION CONTROL SYSTEM INFORMATION
The U.S. and California Clean Air Acts
EPA and California regulations require all manufacturers to furnish
written instructions describing the operation and maintenance of emission control systems. The following instructions and procedures must
be followed in order to keep the emissions from your STANLEY engine
within the emission standards. Maintenance, replacement, or repair of
the emission control devices and systems may be performed by any
engine repair establishment or individual, using parts that are
‘‘certified’’ to EPA standards.
SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious
injury. Read them carefully. If a label comes off or becomes hard to
read, contact your STANLEY generator dealer for a replacement.
SAFETY INFORMATION
STANLEY generators are designed to give safe and dependable
service if operated according to instructions. Read and understand this owner’s manual before operating your generator.
OPERATOR RESPONSIBILITY
Know how to stop the generator quickly in case of emergency. Understand the use of all generator controls, output receptacles, and connections. Be sure that anyone who operates the generator receives
proper instruction. Do not let children operate the generator.
WARNING
The engine exhaust from this product contains chemicals known to
the State of California to cause cancer, birth defects or other reproductive harm.
DANGER
CARBON MONOXIDE GAS
Exhaust contains poisonous carbon monoxide, a colorless and
odorless gas. Breathing exhaust can cause loss of consciousness
and may lead to death. To keep exhaust gas from accumulating,
use in an area with adequate ventilation. DO NOT use this generator in a garage, basement, crawlspace, enclosed shed, or any
other area that does not have adequate ventilation. DO NOT use
this generator near ventilation ducts or open windows that may
allow exhaust
gasses to enter your home or business. ONLY
operate this generator outdoors.
DANGER
Fire and Burn Hazards
The exhaust system gets hot enough to ignite some materials.
Keep the generator at least 3 feet (1 meter) away from buildings
and other equipment during operation.
Do not enclose the generator in any structure.
Do not smoke when refueling.
Keep flammable materials away from the generator.
The muffler becomes very hot during operation and remains hot for
a while after stopping the engine. Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator indoors.
Refuel in a well ventilated area with the engine stopped.
Fuel vapors are extremely flammable and may ignite after the en-
gine has started. Make sure that any spilled fuel has been wiped
up before starting
the generator.
DANGER
Electocution hazard - Electricity can cause DEATH or SERIOUS
INJURY.
Do not operate the generator when moisture is present.
This product is not safe to operate in the presence of water or
near water.
Properly ground the generator and verify ground is in place
before each use. Grounding regulations vary by location, consult a qualified local electrician for proper grounding instructions.
Power cords and electrical equipment pose a risk of shock and
electrocution, especially if they are operated in wet conditions.
Inspect all equipment prior to every use and use only as directed by the manufacturer.
Use a cord with GFCI protection when using the power out-
doors or when moisture is present.
Generators vibrate in normal use. During and after the use of
the generator, inspect the generator as well as extension cords
and power supply cords connected to it for damage resulting
from vibration. Have damaged items repaired or replaced as
necessary. Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades.
NEVER START OR STOP THE ENGINE WITH DEVICES CONNECTED TO THE GENERATOR.
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
No part of this publication can be printed or copied without written permission.
WARNING
Do not connect this generator to a building electrical system.
Improper connections to a building electrical system can allow
electrical current from the generator to backfeed into the utility
lines. Such backfeed may electrocute utility company workers or
others who contact the lines during a power outage, and the generator may explode, burn, or cause fires when utility power is restored.
Ground System
STANLEY portable generators have a system ground that connects generator frame components to the ground terminals in the AC output receptacles. The system ground is connected to the AC neutral wire.
Special Requirements
There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the
intended use of the generator. Please consult a qualified electrician,
electrical inspector, or the local agency having jurisdiction.
This generator does not meet US Coast Guard regulation 33 CFR-183
and should not be used on marine applications.
4 of 16 Rev. 7/2010

WARNINGS
CSA and UL Warning
DANGER
(I) WARNING: USING A GENERATOR INDOORS CAN KILL
YOU IN MINUTES;
(II) GENERATOR EXHAUST CONTAINS CARBON
MONOXIDE, POISONOUS GAS YOU CANNOT SEE OR
SMELL;
(III) NEVER USE IN THE HOME OR IN PARTLY ENCLOSED
AREAS SUCH AS GARAGES; AND USE ONLY OUTSIDE
AND FAR FROM OPEN WINDOWS, DOORS, AND
VENTS.
(IV) THERE IS A PERMANENT CONDUCTOR BETWEEN THE
GENERATOR (STATOR WINDING) AND THE FRAME.
Models: G2250S & G3250S
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
No part of this publication can be printed or copied without written permission.
5 of 16 Rev. 7/2010