Stanley G2250S Owner's Manual

®
Owner's Manual
This manual contains important safety instructions for gasoline generator models: G2250S, G3250S
that should be followed during operation and maintenance of the generator.
READ SAFETYWARNINGS AND OPERATING INSTRUCTIONS CAREFULLY,SAVE THESE INSTRUCTIONS.
Contents: 2-3 3
4 5-6
7-8 9
10-11
12-13
14-15
STANLEYProduct Lines
Missing Parts RequestForm
Warnings Warnings andSpecifications
ComponentIdentification
Assembly andOptionalWheel Kit Installation
Controls Operatingthe Generator
Maintenance, Transporting andStorage
Troubleshooting Warranty and Service
or go to
www.portablegenerator911.com or www.GXiOutdoorPower.com
Have the following information ready when you call us:
Date of Purchase: Location of Purchase:
Serial #:
Rev. 7/2010
STANLEY is a registered trademark ofThe Stanley Works or its affiliates and are used under license by GXiOutdoor Power LLC.
No part of this publication can be printed or copied without written permission.
DONOT RETURNTHIS GENERATOR
TO THE STORE
HAVE QUESTIONS OR NEED HELP? call our help-line: [1] 919-550-3259
I of 16
STANLEYProduct Lines Models:G2250S&G3250S
Walk Behind Turf and Brush Mowers
36" Brush Mower
HONDAGXV530V-twin engine
Hydro Drive
Convertible deck-- easily converts to a finish mower.
Zero-Turn Commercial Mowers
54" and 62"
HONDA and Robin Subaru engines
Hydro Drive
100" Tow Behind Mower
Model: 100TS
Commercial duty STANLEYtow behind mower
HONDA GXV530 V-twin engine cuts up to 100inches.
52in. brush cut or a 52 in. finish cut mower with wings up.
Rev. 7/2010
STANLEY is a registered trademark ofThe Stanley Works or its affiliates and are used under license by GXiOutdoor Power LLC.
No part of this publication can be printed or copied without written permission.
Commercial Walk Behind Mowers
36" and 54" deck
HONDA GXV530 V-twin engine
Belt drive or Hydro Drive
2of16
STANLEY Product Lines Models:G2250S&G3250S
Electric Pressure Washers
1450psito 1800psi electric pressure washers
20ft of high pressure hoseand 35ft. cord with GFCIprotection
Sleekand unique, high quality, stainlesssteel finish
13Amps, 120V
Auto-stop shut off system prolongs pump life
Generator Cord Accessories
240V,10/4,heavy duty extension cords with L14-30connectors at each end.
Reduces harmful voltage drops experienced when using smaller gauge cords.
Available in 15'and 25' lengths
Can be combined to reach the desired length.
All Weather Storm Generators
Patentpending, all weather design
Safeto operate in rainy,wet conditions
Commercial duty engine.
Nomaintenance, copper, brushless alternator.
Missing Parts Request Form
Pleaseindicate the part that you are missing:
[] Hardwarebag Name [] Other
[] Dateofpurchase Address Model#: Email
[] e225os [] G3250S
[] Serial#:
Comments: Phone
IMPORTANT: Please include a copy your receipt. Without a receipt, your order will be delayed.
E-mail customerservic e@gxioutdoorpower.com Fax: 1-919-550-3277
Rev. 7/2010
STANLEY is a registered trademark ofThe Stanley Works or its affiliates and are used under license by GXiOutdoor Power LLC.
No part of this publication can be printed or copied without written permission.
3of16
WAR NIN6S Models:G2250S&G3250S
This owner's manual is considered a permanent part ofthe generator andshould remain with the generator if resold. The information and specifications included inthis publication were in effect atthe time of approval for printing.
GXiOutdoor Power, LLC,reserves the right to discontinue or change specifications or design at anytime without notice and without incur- ring any obligation whatever. No part of this publication may be repro- duced without written permission.
EMISSION CONTROLSYSTEM INFORMATION
The U.S.and California CleanAir Acts
EPAand California regulations require all manufacturers to furnish written instructions describing the operation and maintenance of emis- sion control systems.Thefollowing instructions and procedures must
befollowed in order to keepthe emissions from your STANLEYengine within the emission standards. Maintenance, replacement, or repair of the emission control devices and systems may beperformed by any
engine repair establishment or individual, usingparts that are "certified" to EPAstandards.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other re-
productive harm.
CARBONMONOXIDE GAS
Exhaust contains poisonous carbon monoxide, a colorless and odorless gas. Breathing exhaust can cause loss of consciousness and may lead to death. To keep exhaust gas from accumulating, use in an area with adequate ventilation. DONOT use this genera-
tor in a garage, basement, crawlspace, enclosed shed, or any
other area that does not have adequate ventilation. DO NOT use
this generator near ventilation ducts or open windows that may
allow exhaust gasses to enter your home or business. ONLY operate this generator outdoors.
SAFETYLABEL LOCATIONS These labels warn you of potential hazardsthat can cause serious
injury. Readthem carefully. Ifa label comes off or becomes hardto
read, contact your STANLEYgenerator dealer for a replacement.
SAFETYINFORMATION STANLEYgenerators are designed to givesafe and dependable
service if operated according to instructions. Readand under- stand this owner's manual before operating your generator.
OPERATORRESPONSIBILITY Know howto stop the generator quickly incase of emergency. Under-
standthe useof all generator controls, output receptacles, and con- nections. Be sure that anyonewho operates the generator receives
proper instruction. Donot let children operate the generator.
Electocution hazard - Electricity can cause DEATH or SERIOUS INJURY.
Do not operate the generator when moisture is present.
This product is not safe to operate in the presence of water or nearwater.
Properly ground the generator and verify ground is in place before each use. Grounding regulations vary by location, con- sult a qualified local electrician for proper grounding instruc-
tions.
Power cords and electrical equipment pose a risk of shock and electrocution, especially if they are operated in wet conditions.
Inspect all equipment prior to every use and use only asdi- rected by the manufacturer.
Use a cord with GFCIprotection when using the power out- doors or when moisture is present.
Generators vibrate in normal use. During and after the use of
the generator, inspect the generator aswell as extension cords
and power supply cords connected to it for damage resulting from vibration. Have damaged items repaired or replaced as
necessary. Do not use plugs or cords that show signs of dam- age such as broken or cracked insulation or damaged blades.
Fire and Burn Hazards
The exhaust systemgets hot enough to ignite some materials.
Keepthe generator at least 3 feet (1meter) away from buildings andother equipment during operation.
Donot enclose the generator in any structure.
Donot smoke when refueling.
Keepflammable materials away from the generator.
The muffler becomes very hot during operation and remains hot for awhile after stopping the engine. Be careful not to touch the muf-
fler while it is hot.
Letthe engine cool before storing the generator indoors.
Refuelin a well ventilated area with the engine stopped.
Fuelvapors are extremely flammable and may ignite after the en- gine has started. Make sure that any spilled fuel has been wiped up before starting the generator.
Do not connectthis generator to a building electrical system.
Improper connections to a building electrical system can allow
electrical current from the generator to backfeed into the utility
lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and the gen- erator may explode, burn, or cause fires when utility power is re-
stored.
Ground System STANLEYportable generators havea system ground that connects gen-
erator frame components to the ground terminals inthe AC output re-
ceptacles. Thesystem ground is connected to the AC neutral wire.
Special Requirements There may beFederal or State Occupational Safety and Health Admini- stration (OSHA)regulations, local codes,or ordinances that apply to the
intended use ofthe generator. Pleaseconsult a qualified electrician,
electrical inspector, orthe local agency havingjurisdiction.
This generator does not meet USCoast Guard regulation 33 CFR-183 and should not be used on marine applications.
NEVERSTARTORSTOPTHEENGINEWITHDEVICESCON- NECTEDTOTHEGENERATOR.
Rev. 7/2010
STANLEY is a registered trademark ofThe Stanley Works or its affiliates and are used under license by GXiOutdoor Power LLC.
No part of this publication can be printed or copied without written permission.
4of16
WARN INGS Models: G2250S& G3250S
CSA and UL Warning
WARNING: USING A GENERATORINDOORSCAN KILL
(i)
YOU IN MINUTES;
(11)
GENERATOREXHAUSTCONTAINS CARBON MONOXIDE, POISONOUSGAS YOU CANNOT SEEOR
SMELL; NEVERUSEIN THE HOME ORIN PARTLYENCLOSED
(111)
AREASSUCHAS GARAGES;AND USE ONLYOUTSIDE AND FARFROMOPENWINDOWS, DOORS,AND VENTS.
(IV) THEREISA PERMANENT CONDUCTORBETWEENTHE
GENERATOR(STATORWINDING) AND THE FRAME.
Usinga generatorindoorsCANKILLYOUiN MINUTES,
Generatore×haastcontainscarbonmonoxide.Thisis_paisen
NEVERuseinsideahome or#arage,EVENtFdoors
andwindowsareopen,
yeacannotseear smetl.
Onlyuse0UTSiOEand farawayfromwindows,
deers, and vents.
Avoid ether generator hazards.
READMANUAL8EFOREUSE_
Rev. 7/2010
STANLEY is a registered trademark ofThe Stanley Works or its affiliates and are used under license by GXiOutdoor Power LLC.
No part of this publication can be printed or copied without written permission.
5of16
Loading...
+ 11 hidden pages