Stanley BR50 User Manual

Page 1
BR50
HYDRAULIC
BREAKER
USER MANUAL
© 2012 Stanley Black & Decker, Inc.
New Britain, CT 06053
U.S.A.
72962 3/2017 Ver. 7
Page 2
Weisbeck, Andy
Directive/Standards
No.
Approved body
ISO
28927-10:2011
Self
DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY ÜBEREINSTIMMUNGS-ERKLARUNG DECLARATION DE CONFORMITE CEE
Hydraulic Tools
DECLARACION DE CONFORMIDAD DICHIARAZIONE DI CONFORMITA
______________________________________________________________________
I, the undersigned: Ich, der Unterzeichnende: Je soussigné: El abajo firmante: lo sottoscritto:
hereby declare that the equipment specified hereunder: bestätige hiermit, daß erklaren Produkt genannten Werk oder Gerät: déclare que l’équipement visé ci-dessous: Por la presente declaro que el equipo se especifica a continuación: Dichiaro che le apparecchiature specificate di seguito:
1. Category: Hydraulic Hand Held Concrete Breaker Kategorie: Catégorie: Categoria: Categoria:
2. Make/Marke/Marque/Marca/Marca Stanley
3. Type/Typ/Type/Tipo/Tipo: BR5017801, BR5017801AA, BR5057801, BR5057801AA
4. Serial number of equipment: Seriennummer des Geräts: Numéro de série de l’équipement: Numero de serie del equipo: Matricola dell´attrezzatura:
5. Mass/Masse/Masse/Masa/Massa 25 kg
Has been manufactured in conformity with Wurde hergestellt in Übereinstimmung mit Est fabriqué conformément Ha sido fabricado de acuerdo con E’ stata costruita in conformitá con
Surname and First names/Familiennname und Vornamen/Nom et prénom/ Nombre y apellido/Cognome e nome
All
Richtlinie/Standards Directives/Normes Directriz/Los Normas Direttiva/Norme
ISO Noise Directive
Machinery Directive
6. Special Provisions: None 7. Measurements: Measured Sound Power Level 102 LwA Spezielle Bestimmungen: Messungen Guaranteed Sound Power Level 104 LwA Dispositions particulières: Mesures Measured in accordance to Directive 2000/14/EC, Provisiones especiales: Mediciones Annex III, Part B, No 10, 15 < m < 30 Disposizioni speciali: Misurazioni
8. Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France. Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione
Done at/Ort/Fait à/Dado en/Fatto a Stanley Hydraulic Tools, Milwaukie, Oregon USA Date/Datum/le/Fecha/Data 8-4-2015
Signature/Unterschrift/Signature/Firma/Firma
Position/Position/Fonction/Cargo/Posizione Director of Product Development
Nr Numéro No n.
11148-4:2012 2000/14/EC:2005 3744:2010
2006/42/EC:2006
2 ► BR50 User Manual
Prüfung durch Organisme agréé Aprobado Collaudato
Self AkustikNet (Notified body ID 1585) Bagsvard Hovedgade 141, 2880 Bagsvard, Denmark Certificate #863/2011/003 (verification 2015-08-04) Valid 12/31/2018 Self
Page 3
WARNING
TABLE OF CONTENTS
DECLARATION OF CONFORMITY .......................................................................................................................... 2
SAFETY SYMBOLS ..................................................................................................................................................4
SAFETY PRECAUTIONS .......................................................................................................................................... 5
TOOL STICKERS & TAGS ........................................................................................................................................7
HOSE TYPES ............................................................................................................................................................8
HOSE RECOMMENDATIONS ..................................................................................................................................9
FIGURE 1. TYPICAL HOSE CONNECTIONS .......................................................................................................9
HTMA REQUIREMENTS .........................................................................................................................................10
OPERATION ............................................................................................................................................................ 11
TOOL PROTECTION & CARE ................................................................................................................................12
TROUBLESHOOTING ............................................................................................................................................13
CHARGING THE ACCUMULATOR .........................................................................................................................14
FIGURE 2. CHARGING THE ACCUMULATOR ................................................................................................... 14
SPECIFICATIONS ................................................................................................................................................... 15
TEST EQUIPMENT .................................................................................................................................................16
SERVICE TOOLS ....................................................................................................................................................16
ACCESSORIES.......................................................................................................................................................17
BR50 T-HANDLE ILLUSTRATION .......................................................................................................................... 18
BR50 T-HANDLE PARTS LIST ................................................................................................................................ 19
BR50 ANTI-VIB ILLUSTRATION ............................................................................................................................. 20
BR50 ANTI-VIB PARTS LIST ..................................................................................................................................21
BREAKER FOOT PARTS LIST ............................................................................................................... 22 THRU 26
IMPORTANT
To ll out a Product Warranty Validation form, and for information on your warranty,
visit Stanleyhydraulics.com and select the Company tab, Warranty.
(NOTE: The warranty Validation record must be submitted to validate the warranty).
SERVICING: This manual contains safety, operation, and routine maintenance instructions. Stanley Hydraulic Tools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized
and certied dealer. Please read the following warning.
SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR
SERVICE OF THIS TOOL.
REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN
AUTHORIZED AND CERTIFIED DEALER.
For the nearest authorized and certied dealer, call Stanley Hydraulic Tools at the number listed on the back of this
manual and ask for a Customer Service Representative.
BR50 User Manual ◄ 3
Page 4
DANGER
WARNING
CAUTION
CAUTION
NOTICE
IMPORTANT
SAFETY SYMBOLS
Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair actions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
This safety alert and signal word indicate an imminently hazardous situation which, if not avoided, will result in death or serious injury.
This safety alert and signal word indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This safety alert and signal word indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This signal word indicates a potentially hazardous situation which, if not avoided, may result in property damage.
This signal word indicates a situation which, if not avoided, will result in damage to the equipment.
This signal word indicates a situation which, if not avoided, may result in damage to the equipment.
Always observe safety symbols. They are included for your safety and for the protection of the tool.
LOCAL SAFETY REGULATIONS
Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and maintenance personnel.
4 ► BR50 User Manual
Page 5
SAFETY PRECAUTIONS
Tool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose.
These safety precautions are given for your safety. Review them carefully before operating the tool and before performing general maintenance or repairs.
Supervising personnel should develop additional
precautions relating to the specic work area and local
safety regulations. If so, place the added precautions in the space provided in this manual.
The BR50 Hydraulic Breaker will provide safe and dependable service if operated in accordance with the instructions given in this manual. Read and understand this manual and any stickers and tags attached to the tool and hoses before operation. Failure to do so could result in personal injury or equipment damage.
Operator must start in a work area without
bystanders. The operator must be familiar with all prohibited work areas such as excessive slopes and dangerous terrain conditions.
Establish a training program for all operators to
ensure safe operation.
Do not operate the tool unless thoroughly trained or
under the supervision of an instructor.
Always wear safety equipment such as goggles,
gloves, ear, head, and breathing protection, and safety shoes at all times when operating the tool.
Do not inspect, carry or clean the tool while the
hydraulic power source is connected. Accidental engagement of the tool can cause serious injury.
Supply hoses must have a minimum working
pressure rating of 2500 psi/175 bar.
Be sure all hose connections are tight.
The hydraulic circuit control valve must be in the
OFF position when coupling or uncoupling the tool. Wipe all couplers clean before connecting. Use only lint-free cloths. Failure to do so may result in damage to the quick couplers and cause overheating of the hydraulic system.
Do not operate the tool at oil temperatures above
140 °F/60 °C. Operation at higher oil temperatures can cause operator discomfort and may damage the tool. Never come in contact with the tool bit, the bit can get hot.
Do not operate a damaged, improperly adjusted, or incompletely assembled tool.
Do not weld, cut with an acetylene torch or hard­face the tool bit.
To avoid personal injury or equipment damage, all tool repair, maintenance and service must only be performed by authorized and properly trained personnel.
Do not exceed the rated limits of the tool or use the tool for applications beyond its design capacity.
Always keep critical tool markings, such as labels and warning stickers legible.
Always replace parts with replacement parts recommended by Stanley Hydraulic Tools.
Check fastener tightness often and before each use daily.
Never operate the tool if you cannot be sure that underground utilities are not present.
Do not wear loose tting clothing when operating the tool.
Warning: Use of this tool on certain materials during demolition could generate dust potentially containing a variety of hazardous substances such as asbestos, silica or lead. Inhalation of dust containing these or other hazardous substances could result in serious injury, cancer or death. Protect yourself and those around you. Research and understand the materials you are cutting. Follow correct safety procedures and comply with all applicable national, state or provisional health and safety regulations relating to them, including, if appropriate, arranging for the safe
disposal of the materials by a qualied person.
BR50 User Manual ◄ 5
Page 6
SAFETY PRECAUTIONS
Warning: Hydraulic uid under pressure could cause skin injection injury. If you are injured by hydraulic
uid, get medical attention immediately.
Keep all body parts away from the working tool.
When handling material or the tool bit, wear your Personal Protection Equipment (PPE).
Be observant of the hydraulic hoses lying about the work area as they can be a tripping hazard.
Always de-energize the hydraulic system when changing a tool bit.
Take caution when changing a tool bit. Tool bits can get very hot.
Never use the tool in an explosive atmosphere. Sparks from the breaking process could ignite explosive gas.
Use proper lifting techniques when handling the tool. Get help from a co-worker and do not over-reach.
Use proper protection from falling or ying debris, and keep bystanders at a safe distance.
Do not exceed the rated ow and pressure. See
Specications in this manual for correct ow rate
and pressure rating. Rapid failure of the internal seals may result.
6 ► BR50 User Manual
Page 7
TOOL STICKERS & TAGS
28322 CE Sticker
74832 Stanley Logo
28409 Composite Sticker All Models
11207 Circuit Type D Sticker BR5017801
65458 Guaranteed Sound Level Sticker
11208 Hex Shank Length Sticker
10180 Caution N2 Gas Sticker
NOTE:
THE INFORMATION LISTED
ON THE STICKERS SHOWN,
MUST BE LEGIBLE AT ALL
TIMES.
REPLACE DECALS IF
THEY BECOME WORN OR
DAMAGED. REPLACEMENTS
ARE AVAILABLE FROM
YOUR LOCAL STANLEY
DISTRIBUTOR.
The safety tag (P/N 15875) at right is attached to the tool when shipped from the factory. Read and understand the safety instructions listed on this tag before removal. We suggest you retain this tag and attach it to the tool when not in use.
BR50 BREAKE
R
74665 5-gpm Anti-Vib Name Tag Sticker (BR5057801 only)
74661 8-gpm Anti-Vib Name Tag Sticker (BR50125, BR50135 and BR5017801 only)
74662 8-gpm T-Handle Name Tag Sticker (BR50120, BR50120E, BR50130 and BR50130E only)
1. FAILURE TO USE HYDRAULIC HOSE LABELED AND CER­TIFIED AS NON-CONDUCTIVE WHEN USING HYDRAULIC TOOLS ON OR NEAR ELECTRICAL LINES MAY RESULT IN DEATH OR SERIOUS INJURY.
BEFORE USING HOSE LABELED AND CERTIFIED AS NON- CONDUCTIVE ON OR NEAR ELECTRIC LINES BE SURE THE HOSE IS MAINTAINED AS NON-CONDUCTIVE. THE HOSE SHOULD BE REGULARLY TESTED FOR ELECTRIC CUR­RENT LEAKAGE IN ACCORDANCE WITH YOUR SAFETY DEPARTMENT INSTRUCTIONS.
2. A HYDRAULIC LEAK OR BURST MAY CAUSE OIL INJEC­TION INTO THE BODY OR CAUSE OTHER SEVERE PERSONAL INJURY.
A. DO NOT EXCEED SPECIFIED FLOW AND PRESSURE
FOR THIS TOOL. EXCESS FLOW OR PRESSURE MAY CAUSE A LEAK OR BURST.
B. DO NOT EXCEED RATED WORKING PRESSURE OF
HYDRAULIC HOSE USED WITH THIS TOOL. EXCESS PRESSURE MAY CAUSE A LEAK OR BURST.
C. CHECK TOOL HOSE COUPLERS AND CONNECTORS
DAILY FOR LEAKS. DO NOT FEEL FOR LEAKS WITH YOUR HANDS. CONTACT WITH A LEAK MAY RESULT IN SEVERE PERSONAL INJURY.
IMPORTANT
READ OPERATION MANUAL AND
SAFETY INSTRUCTIONS FOR THIS
TOOL BEFORE USING IT.
USE ONLY PARTS AND REPAIR
PROCEDURES APPROVED BY
STANLEY AND DESCRIBED IN THE
OPERATION MANUAL.
TAG TO BE REMOVED ONLY BY
TOOL OPERATOR.
SEE OTHER SIDE
D. DO NOT LIFT OR CARRY TOOL BY THE HOSES. DO
NOT ABUSE HOSE. DO NOT USE KINKED, TORN OR DAMAGED HOSE.
3. MAKE SURE HYDRAULIC HOSES ARE PROPERLY CON­NECTED TO THE TOOL BEFORE PRESSURING SYSTEM. SYSTEM PRESSURE HOSE MUST ALWAYS BE CON­NECTED TO TOOL “IN” PORT. SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL “OUT” PORT. REVERSING CONNECTIONS MAY CAUSE REVERSE TOOL OPERATION WHICH CAN RESULT IN SEVERE PERSONAL INJURY.
4. DO NOT CONNECT OPEN-CENTER TOOLS TO CLOSED­CENTER HYDRAULIC SYSTEMS. THIS MAY RESULT IN LOSS OF OTHER HYDRAULIC FUNCTIONS POWERED BY THE SAME SYSTEM AND/OR SEVERE PERSONAL INJURY.
5. BYSTANDERS MAY BE INJURED IN YOUR WORK AREA. KEEP BYSTANDERS CLEAR OF YOUR WORK AREA.
6. WEAR HEARING, EYE, FOOT, HAND AND HEAD PRO­TECTION.
7. TO AVOID PERSONAL INJURY OR EQUIPMENT DAMAGE, ALL TOOL REPAIR MAINTENANCE AND SERVICE MUST ONLY BE PERFORMED BY AUTHORIZED AND PROPERLY TRAINED PERSONNEL.
IMPORTANT
READ OPERATION MANUAL AND
SAFETY INSTRUCTIONS FOR THIS
USE ONLY PARTS AND REPAIR
PROCEDURES APPROVED BY
STANLEY AND DESCRIBED IN THE
TAG TO BE REMOVED ONLY BY
SAFETY TAG P/N 15875 (Shown smaller then actual size)
These numbers are for example only and may not relate to your model of breaker, see part numbers below for name tag stickers that
ts your model
breaker.
DANGERDANGER
TOOL BEFORE USING IT.
OPERATION MANUAL.
TOOL OPERATOR.
SEE OTHER SIDE
BR50 User Manual ◄ 7
Page 8
HOSE TYPES
The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hydraulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic Tools. They are:
Certied non-conductive — constructed of thermoplastic or synthetic rubber inner tube, synthetic ber braid
reinforcement, and weather resistant thermoplastic or synthetic rubber cover. Hose labeled certied non- conductive is the only hose authorized for use near electrical conductors.
Wire-braided (conductive) — constructed of synthetic rubber inner tube, single or double wire braid reinforcement, and weather resistant synthetic rubber cover. This hose is conductive and must never be used
near electrical conductors.
Fabric-braided (not certied or labeled non-conductive) — constructed of thermoplastic or synthetic rubber inner tube, synthetic ber braid reinforcement, and weather resistant thermoplastic or synthetic rubber cover.
This hose is not certied non-conductive and must never be used near electrical conductors.
HOSE SAFETY TAGS
To help ensure your safety, the following DANGER tags are attached to all hose purchased from Stanley Hydraulic Tools. DO NOT REMOVE THESE TAGS.
If the information on a tag is illegible because of wear or damage, replace the tag immediately. A new tag may be obtained from your Stanley Distributor.
THE TAG SHOWN BELOW IS ATTACHED TO “CERTIFIED NON-CONDUCTIVE” HOSE
DANGER
1. FAILURE TO USE HYDRAULIC HOSE LABELED AND CERTIFIED AS NON-CONDUCTIVE WHEN USING HYDRAULIC TOOLS ON OR NEAR ELECTRIC LINES MAY RESULT IN DEATH OR SERIOUS INJURY.
FOR PROPER AND SAFE OPERATION MAKE SURE THAT YOU HAVE BEEN PROP­ERLY TRAINED IN CORRECT PROCEDURES REQUIRED FOR WORK ON OR AROUND ELECTRIC LINES.
2. BEFORE USING HYDRAULIC HOSE LABELED AND CERTIFIED AS NON-CONDUCTIVE ON OR NEAR ELECTRIC LINES. WIPE THE ENTIRE LENGTH OF THE HOSE AND FIT­TING WITH A CLEAN DRY ABSORBENT CLOTH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUM ALLOWABLE CURRENT LEAKAGE IN ACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS.
DO NOT REMOVE THIS TAG
SEE OTHER SIDE
SIDE 1
3. DO NOT EXCEED HOSE WORKING PRESSURE OR ABUSE HOSE. IMPROPER USE
OR HANDLING OF HOSE COULD RESULT IN BURST OR OTHER HOSE FAILURE. KEEP HOSE AS FAR AWAY AS POSSIBLE FROM BODY AND DO NOT PERMIT DIRECT CONTACT DURING USE. CONTACT AT THE BURST CAN CAUSE BODILY INJECTION AND SEVERE PERSONAL INJURY.
4. HANDLE AND ROUTE HOSE CAREFULLY TO AVOID KINKING, ABRASION, CUTTING, OR
CONTACT WITH HIGH TEMPERATURE SURFACES. DO NOT USE IF KINKED. DO NOT USE HOSE TO PULL OR LIFT TOOLS, POWER UNITS, ETC.
5. CHECK ENTIRE HOSE FOR CUTS CRACKS LEAKS ABRASIONS, BULGES, OR DAM­AGE TO COUPLINGS IF ANY OF THESE CONDITIONS EXIST, REPLACE THE HOSE IMMEDIATELY. NEVER USE TAPE OR ANY DEVICE TO ATTEMPT TO MEND THE HOSE.
6. AFTER EACH USE STORE IN A CLEAN DRY AREA.
(Shown smaller than actual size)
DANGER
DANGER
SEE OTHER SIDE
SIDE 2
THE TAG SHOWN BELOW IS ATTACHED TO “CONDUCTIVE” HOSE.
DANGER
DANGER
1. DO NOT USE THIS HYDRAULIC HOSE ON OR NEAR ELECTRIC LINES. THIS HOSE IS NOT LABELED OR CERTIFIED AS NON-CONDUCTIVE. USING THIS HOSE ON OR NEAR ELECTRICAL LINES MAY RESULT IN DEATH OR SERIOUS INJURY.
2. FOR PROPER AND SAFE OPERATION MAKE SURE THAT YOU HAVE BEEN PROPERLY TRAINED IN CORRECT PROCEDURES REQUIRED FOR WORK ON OR AROUND ELEC­TRIC LINES.
3. DO NOT EXCEED HOSE WORKING PRESSURE OR ABUSE HOSE. IMPROPER USE OR HANDLING OF HOSE COULD RESULT IN BURST OR OTHER HOSE FAILURE. KEEP HOSE AS FAR AWAY AS POSSIBLE FROM BODY AND DO NOT PERMIT DIRECT CONTACT DURING USE. CONTACT AT THE BURST CAN CAUSE BODILY INJECTION AND SEVERE PERSONAL INJURY.
4. HANDLE AND ROUTE HOSE CAREFULLY TO AVOID KINKING, CUTTING, OR CONTACT WITH HIGH TEMPERATURE SURFACES. DO NOT USE IF KINKED. DO NOT USE HOSE TO PULL OR LIFT TOOLS, POWER UNITS, ETC.
DO NOT REMOVE THIS TAG
SEE OTHER SIDE
SIDE 1
5. CHECK ENTIRE HOSE FOR CUTS CRACKS LEAKS ABRASIONS, BULGES, OR DAMAGE TO COUPLINGS IF ANY OF THESE CONDITIONS EXIST, REPLACE THE HOSE IMMEDIATELY. NEVER USE TAPE OR ANY DEVICE TO ATTEMPT TO MEND THE HOSE.
6. AFTER EACH USE STORE IN A CLEAN DRY AREA.
(Shown smaller than actual size)
DANGER
SEE OTHER SIDE
SIDE 2
DO NOT REMOVE THIS TAG
DO NOT REMOVE THIS TAG
8 ► BR50 User Manual
Page 9
Min. Working Pressure
USE
(Press/Return)
HOSE RECOMMENDATIONS
Certied Non-Conductive Hose - Fiber Braid - for Utility Bucket Trucks
Oil Flow Hose Lengths Inside Diameter
GPM LPM FEET METERS INCH MM PSI BAR
4-9 15-34 up to 10 up to 3 3/8 10 Both 2250 155
Conductive Hose - Wire Braid or Fiber Braid -DO NOT USE NEAR ELECTRICAL CONDUCTORS
4-6 15-23 up to 25 up to 7.5 3/8 10 Both 2500 175
4-6 15-23 26-100 7.5-30 1/2 13 Both 2500 175
5-10.5 19-40 up to 50 up to 15 1/2 13 Both 2500 175
5-10.5 19-40 51-100 15-30 5/8 16 Both 2500 175
5/8 16 Pressure 2500 175
3/4 19 Return 2500 175
5-10.5 19-40 100-300 30-90
10-13 38-49 up to 50 up to 15 5/8 16 Both 2500 175
5/8 16 Pressure 2500 175
3/4 19 Return 2500 175
10-13 38-49 51-100 15-30
3/4 19 Pressure 2500 175
1 25.4 Return 2500 175
10-13 38-49 100-200 30-60
5/8 16 Pressure 2500 175
13-16 49-60 up to 25 up to 8
3/4 19 Return 2500 175
3/4 19 Pressure 2500 175
1 25.4 Return 2500 175
13-16 49-60 26-100 8-30
PRESSURE
<<< FLOW
RETURN
FLOW >>>
Figure 1. Typical Hose Connections
Tool to Hydraulic Circuit Hose
Recommendations
The chart to the right shows recommended
minimum hose diameters for various
hose lengths based on gallons per minute
(gpm)/liters per minute (lpm). These
recommendations are intended to keep return
line pressure (back pressure) to a minimum
acceptable level to ensure maximum tool
performance.
This chart is intended to be used for hydraulic
tool applications only based on Stanley
Hydraulic Tools tool operating requirements
and should not be used for any other
applications.
All hydraulic hose must have at least a
rated minimum working pressure equal to
the maximum hydraulic system relief valve
setting.
All hydraulic hose must meet or exceed
specications as set forth by SAE J517.
BR50 User Manual ◄ 9
Page 10
HTMA / EHTMA REQUIREMENTS
HTMA / EHTMA REQUIREMENTS
HTMA HYDRAULIC SYSTEM REQUIREMENTS
Flow Range
Nominal Operating Pressure (at the power supply outlet)
System relief valve setting (at the power supply outlet)
Maximum back pressure (at tool end of the return hose)
(at min. operating temperature)
(at max. expected ambient temperature)
Min. cooling capacity at a temperature
temps NOTE: Do not operate the tool at oil temperatures above 140° F (60° C). Operation at higher temperatures can cause operator discomfort at the tool.
Filter
(For cold temp. startup and max. dirt-holding capacity)
4-6 gpm 7-9 gpm 9-10.5 gpm 11-13 gpm (15-23 lpm) (26-34 lpm) (34-40 lpm) (42-49 lpm) 1500 psi 1500 psi 1500 psi 1500 psi (103 bar) (103 bar) (103 bar) (103 bar)
2100-2250 psi 2100-2250 psi 2200-2300 psi 2100-2250 psi (145-155 bar) (145-155 bar) (152-159 bar) (145-155 bar)
250 psi 250 psi 250 psi 250 psi (17 bar) (17 bar) (17 bar) (17 bar)
400 ssu* 400 ssu* 400 ssu* 400 ssu* (82 centistokes) (82 centistokes) (82 centistokes) (82 centistokes)
140° F 140° F 140° F 140° F (60° C) (60° C) (60° C) (60° C)
3 hp 5 hp 6 hp 7 hp (2.24 kW) (3.73 kW) (5.22 kW) (4.47 kW) 40° F 40° F 40° F 40° F (22° C) (22° C) (22° C) (22° C)
25 microns 25 microns 25 microns 25 microns 30 gpm 30 gpm 30 gpm 30 gpm (114 lpm) (114 lpm) (114 lpm) (114 lpm)
TYPE I TYPE II
TOOL TYPE
TYPE RR
TYPE III
(premium grade, anti-wear, non-conductive) Viscosity (at min. and max. operating temps)
NOTE:
over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal
EHTMA HYDRAULIC SYSTEM REQUIREMENTS
Flow Range
Nominal Operating Pressure (at the power supply outlet)
System relief valve setting (at the power supply outlet)
NOTE:
100-400 ssu* 100-400 ssu* 100-400 ssu* 100-400 ssu* (20-82 centistokes)
CLASSIFICATION
B
3.5-4.3 gpm 4.7-5.8 gpm 7.1-8.7 gpm 9.5-11.6 gpm 11.8-14.5 gpm (13.5-16.5 lpm) (18-22 lpm) (27-33 lpm) (36-44 lpm) (45-55 lpm) 1870 psi 1500 psi 1500 psi 1500 psi 1500 psi (129 bar) (103 bar) (103 bar) (103 bar) (103 bar)
2495 psi 2000 psi 2000 psi 2000 psi 2000 psi (172 bar) (138 bar) (138 bar) (138 bar) (138 bar)
C
D
.
10 ► BR50 User Manual
Page 11
OPERATION
The recommended hose size is .500 inch/12 mm ID up to 50 ft/15 m long and .625 inch/16 mm ID minimum up to 100 ft/30 m.
PRE-OPERATION PROCEDURES
CHECK POWER SOURCE
1. Using a calibrated owmeter and pressure gauge, check that the hydraulic power source develops a
ow of 7–9 gpm/26–34 lpm at 2000 psi/140 bar or 5–6 gpm /18–22 lpm at 1500–2000 psi /105–140
bar.
2. Make certain the hydraulic power source is equipped with a relief valve set to open at 2250 psi/155 bar maximum.
INSTALL TOOL BIT
1. Rotate the latch on the breaker foot downward (pointing away from the tool).
2. Insert the tool bit into the foot and pull the latch up to lock the tool bit in place.
CONNECT HOSES
1. Wipe all hose couplers with a clean, lint-free cloth before making connections.
2. Connect the hoses from the hydraulic power source
to the tool ttings or quick disconnects. It is a good practice to connect return hoses rst and disconnect
them last to minimize or avoid trapped pressure within the tool.
3. Observe ow indicators stamped on hose couplers
to ensure that uid ow is in the proper direction. The
female coupler on the tool hose is the inlet coupler.
4. Move the hydraulic circuit control valve to the ON position to operate the tool.
NOTE: If uncoupled hoses are left in the sun, pressure
increase within the hoses may make them difcult to connect. When possible, connect the free ends of the hoses together.
NOTE: Partially depressing the trigger allows the tool to run
at slow speed. Slow-speed operation permits easier starting of the tool bit into the work surface.
5. To start, break an opening (hole) in the center of the surface. After making a hole, break portions of the material into the original opening. For best productivity, the breaking should be done around the original hole.
The size of the broken material will vary with the strength and thickness of the base material and the amount of any reinforcement wire or rebar.
Harder material or more reinforcing wire or rebar will require taking smaller bites. To determine the most effective bite, start with 2 in./50 mm or smaller bites.
Bites can then be gradually increased until the broken piece becomes too large, requiring increased time to break off the piece.
Sticking of the tool bit occurs when too large a bite is being taken and the tool bit hammers into the material without the material fracturing. This causes the tool bit to become trapped in the surrounding material.
COLD WEATHER OPERATION
If the breaker is to be used during cold weather, preheat
the hydraulic uid at low engine speed. When using the normally recommended uid, uid temperature should
be at or above 50 °F/10 °C (400 ssu/82 centistokes) before use.
Damage to the hydraulic system or breaker can result
from use with uid that is too viscous or thick.
OPERATION PROCEDURES
1. Observe all safety precautions.
2. Install the appropriate tool bit for the job.
3. Place the bit rmly on the surface to be broken.
4. Squeeze the trigger to start the breaker. Adequate down pressure is very important. When the tool bit breaks through the obstruction or becomes bound, release the trigger and reposition the tool bit.
BR50 User Manual ◄ 11
Page 12
NOTICE
TOOL PROTECTION & CARE
In addition to the Safety Precautions found in
this manual, observe the following for equipment
protection and care.
Make sure all couplers are wiped clean before connection.
The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling hydraulic tools. Failure to do so may result in damage to the quick couplers and cause overheating of the hydraulic system.
Always store the tool in a clean dry space, safe from damage or pilferage.
Make sure the circuit PRESSURE hose (with male quick disconnect) is connected to the IN port. The circuit RETURN hose (with female quick disconnect) is connected to the opposite port. Do not reverse
circuit ow. This can cause damage to internal seals.
Always replace hoses, couplings and other parts with replacement parts recommended by Stanley Hydraulic Tools. Supply hoses must have a minimum working pressure rating of 2500 psi/172 bar.
Do not exceed the rated ow and pressure. See
Specications in this manual for correct ow rate
and pressure rating. Rapid failure of the internal seals may result.
Always keep critical tool markings, such as warning stickers and tags legible.
Do not force a small breaker to do the job of a large breaker.
Keep tool bit sharp for maximum breaker performance. Make sure that tool bits are not chipped or rounded on the striking end.
Never operate a breaker without a tool bit or without holding it against the work surface. This puts excessive strain on the breaker foot.
Tool repair should be performed by experienced personnel only.
Make certain that the recommended relief valves are installed in the pressure side of the system.
Do not use the tool for applications for which it was not intended.
12 ► BR50 User Manual
Page 13
TROUBLESHOOTING
PROBLEM CAUSE REMEDY
Tool does not run. Power unit not functioning. Check power source for proper ow
and pressure (7–9 gpm/ 26–34 lpm, 2000 psi/ 140 bar) or 5–6 gpm /18–22 lpm at 1500–2000 psi /105–140 bar.
Couplers or hoses blocked. Remove restriction.
Pressure and return line hoses reversed at ports.
Mechanical failure of piston or automatic valve.
Tool does not hit effectively. Power unit not functioning. Check power source for proper ow
Couplers or hoses blocked. Remove restriction.
Low accumulator charge (pressure hose will pulse more than normal).
Fluid too hot (above 140 °F/60 °C). Provide cooler to maintain proper uid
Tool operates slow. Low gpm supply from power unit. Check power source for proper ow
High back-pressure. Check hydraulic system for excessive
Couplers or hoses blocked. Remove restriction.
Orice plug blocked. Remove restriction.
Fluid too hot (above 140 °F/60 °C) or too cold (below 60 °F/16 °C).
Relief valve set too low. Adjust relief valve to 2100–2250
Collar support not sliding freely in the foot bore (Easi-Ride™).
Tool gets hot. Hot uid going through tool. Check power unit. Be sure ow rate
Fluid leakage on tool bit. Lower piston seal failure. Replace seal.
Fluid leakage around trigger.
Valve spool seal failure. Replace seals.
Be sure hoses are connected to their proper ports.
Disassemble breaker and inspect for damaged parts.
and pressure (7–9 gpm/ 26–34 lpm, 2000 psi/ 140 bar) or 5–6 gpm /18–22 lpm at 1500–2000 psi /105–140 bar.
Recharge accumulator. Replace diaphragm if charge loss continues.
temperature (130 °F/55 °C).
and pressure (7–9 gpm/ 26–34 lpm, 2000 psi/ 140 bar) or 5–6 gpm /18–22 lpm at 1500–2000 psi /105–140 bar.
back-pressure (over 200 psi/14 bar).
Check power unit for proper uid
temperature. Bypass cooler to warm
the uid or provide cooler to maintain
proper temperature.
psi/145–155 bar.
Remove, clean and replace as required.
is not too high causing part of the
uid to go through the relief valve. Provide cooler to maintain proper uid
temperature (140 °F/60 °C max). Check
the relief valve setting. Eliminate ow
control devices.
BR50 User Manual ◄ 13
Page 14
CAUTION
CHARGING THE ACCUMULATOR
ACCUMULATOR TESTING PROCEDURE
To check or charge the accumulator, the following equipment is required:
31254 Charge Kit: which includes the following:
Accumulator Tester (Part Number 02835). – Charging Assembly (P/N 15304: includes a
liquid lled gauge with snub valve, hose and ttings).
NITROGEN bottle with an 800 psi/55 bar minimum charge. (Not included in 31254 kit)
The breaker contains nitrogen under pressure.
1.
Remove the plug from the handle or handle pivot.
2. Holding the chuck end of Accumulator Tester (P/N 02835), turn the gauge fully counterclockwise to ensure that the stem inside the chuck is completely retracted.
3. Thread the tester onto the accumulator charging valve. Do not advance the gauge-end into the chuck-end. Turn as a unit. Seat the chuck on the accumulator charging valve and hand tighten only.
4. Advance the valve stem of the tester by turning the gauge-end clockwise until a pressure is read on the
gauge (charge pressure should be 500–700 psi/34–
48 bar).
5. If pressure is OK unscrew the gauge-end from the chuck to retract the stem, then unscrew the entire tester assembly from the accumulator charging valve. If pressure is low, charge the accumulator as described in the following section.
6. Install the plug.
ACCUMULATOR CHARGING
1. Perform Steps 1 through 4 of the Accumulator Testing procedure.
2. Connect the chuck of the charging assembly to the charging valve on the accumulator tester or, if preferred, remove the tester from the charging valve and connect the charging assembly chuck directly to the charging valve.
3. Adjust the snub valve to a charging pressure of 600 psi/42 bar. Note: While watching the pressure gauge, open snub valve slowly until it reaches the
proper charge pressure (600–700 psi).
NOTE: It may be necessary to set the gauge at 650–700
psi/45–48 bar to overcome any pressure drop through the charging system.
4. When the accumulator is fully charged close the snub valve on the charging assembly hose and remove the charging assembly chuck from the accumulator tester or tool charging valve.
5. If the accumulator tester has been used, be sure to turn the gauge-end fully counterclockwise before removing the tester from the charging valve of the tool. Install the valve cap.
Liquid Filled Gauge w/Snub valve
31254 Accumulator Charge Kit: Includes all of the above except the Nitrogen tank
14 ► BR50 User Manual
Nitrogen Tank (Not Included in kit)
Hose
Charge Fitting
Gauge
Figure 2. Charging the Accumulator
Chuck
Location of charge valve on Anti-Vib Models. On T-Handle models charge valve is located on the top of breaker.
Page 15
SPECIFICATIONS
Pressure Range................................................................................................................1500-2000 psi/105-140 bar
Maximum Back Pressure......................................................................................................................250 Psi/17 bar
Flow Range (EHTMA D/HTMA Class II) ...................................................................................... 7–9 gpm/26–34 lpm
Nominal Flow................................... .............................................................. (EHTMA D/HTMA-II) = 8 gpm/30 lpm
Flow Range (EHTMA D/HTMA Class I) ........................................................................................ 4–6 gpm /1–22 lpm
Nominal Flow................................... ............................................................... (EHTMA D/HTMA-I) = 5 gpm/19 lpm
Hose Whips....................................................... .................................................................................................... Yes
Connect Size & Type .......................................................................................................3/8 in Male Pipe Hose Ends
Weight (T-Handle Models) ........................................................................................................................52 lbs/24 kg
(Anti Vib Models) ..........................................................................................................................56 lbs/25 kg
Overall Length ................................................................................................................................... 28.5 in./72.4 cm
Overall Width at Handles ..................................................................................................................... 17.25 in/44 cm
Max. Fluid Temperature .......................................................................................................................... 140 °F/60 °C
System Type ........................................................................................................................................... Open Center
Port Size .................................................................................................................................................SAE 8 O-ring
HTMA/EHTMA Category .............................................................................................................................Type 1 - 2
Nominal Pressure ............................................................................................................................. 1500 psi/103 bar
Max Pressure ................................................................................................................................... 2500 psi/172 bar
Max Relief Pressure ......................................................................................................................... 2150 psi/148 bar
NOTE: Weights, dimensions and operating specications listed herein are subject to change without notice. Where
specications are critical to your applications, please consult Stanley Hydraulic Tools.
BR50 SOUND AND VIBRATION DECLARATION
Test conducted on BR5017801,operated at standard 8 gpm input
Measured A-weighted sound power level, Lwa (ref. 1pW) in decibels 102 dBA Uncertainty, Kwa, in decibels 1.6 dBA Guaranteed sound power level 104 dBA Measured A-weighted sound pressure level, Lpa (ref. 20 µPa) at operator's position, in decibels 98 dBA Uncertainty, Kpa, in decibels 3 dBA Values determined according to noise test code given in ISO 15744, using the basic standard
ISO3744 Test conducted by independent notied body to comply with 2000/14/EC:2005 requirements.
NOTE- The sum of a measured noise emission value and its associated uncertainty represents an upper bound­ary of the range of values which is likely to occur in measurements. Declared vibration emission value in accordance with EN 12096 Measured vibration emission value: 3-Axis 5.9 m/sec² Uncertainty: K 0.5 m/sec² Measurred Vibration emission value with uncertainty (3 Axis) 6.4 m/sec² Measured vibration emission value: Z-Axis 2.4 m/sec² Uncertainty: K 0.5 m/sec² Measurred Vibration emission value with uncertainty (Z Axis) 4 m/sec²
Values determined according to ISO 8662-5, ISO 5349-1,2
BR50 User Manual ◄ 15
Page 16
TEST EQUIPMENT / SERVICE TOOLS
TEST EQUIPMENT
Accumulator Tester ............................................................................................................................................ 02835
Flow and Pressure Tester .................................................................................................................................. 04182
Accumulator Charge Assembly (Includes Liquid Filled Gauge w/ Valve, Hose, & Charge Fitting) .................... 15304
Accumulator Charge Kit (Includes 02835 Tester, 15304 Charge Assy and 372047 Charge Kit Box) ................31254
SERVICE TOOLS
Flow Sleeve Removal Tube ...............................................................................................................................04910
Flow Sleeve Removal Tool ................................................................................................................................ 04919
Accumulator Cylinder Puller ..............................................................................................................................05640
Tamper Sleeve Tool ........................................................................................................................................... 01120
O-ring Tool Kit .................................................................................................................................................... 04337
16 ► BR50 User Manual
Page 17
ACCESSORIES
ACCESSORIES
1-1/8 IN. HEX × 6 IN. SHANK
Moil Point – 14 in. Long UC ............................................................................................................................... 02333
Chisel Point – 14 in. Long UC ...........................................................................................................................03990
3-inch Chisel – 14 in. Long UC .......................................................................................................................... 02334
Clay Spade – 5-1/2 in. Blade ............................................................................................................................. 02331
Asphalt Wedge – 12 in. .....................................................................................................................................08106
Asphalt Cutter – 5 in. Wide ................................................................................................................................ 02332
Ground Rod Driver – 1 in. Rod .......................................................................................................................... 04176
1-1/4 IN. HEX × 6 IN. SHANK
Moil Point – 14 in. Long UC ............................................................................................................................... 02336
3-inch Chisel – 14 in. Long UC .......................................................................................................................... 02337
Clay Spade – 5-1/2 in. Blade ............................................................................................................................. 09262
Asphalt Cutter – 5 in. Wide ................................................................................................................................ 02335
Ground Rod Driver – 1 in. Rod .......................................................................................................................... 04367
Heavy Duty Chisel – 1 in.. .................................................................................................................................02338
Heavy Duty Moil Point – 18 in. ..........................................................................................................................04404
Clay Spade – 8 in. .............................................................................................................................................04405
Detachable Shank (Requires 17783) ................................................................................................................17782
Tamping Pad – 6 in. (Requires 17782) .............................................................................................................. 17783
BR50 User Manual ◄ 17
Page 18
BR50 T-HANDLE ILLUSTRATION
PICTURED IS A BR50120 FOR BREAKER FOOT PARTS THAT PERTAIN TO YOUR MODEL SEE PAGE 22 THRU PAGE 26.
21
28
10
19
2
44
45
46
22
7
6
8
27
20
17
25
23
12
1
11
3
24
18
15
3
11
12
14
16
30
9
26
15
4
5
18 ► BR50 User Manual
13
31
See pages 22 thru 26 for Breaker foot parts.
Page 19
BR50 T-HANDLE PARTS LIST
ITEM P/N QTY DESCRIPTION
1 01652 2 HOSE WHIP 12"
2 02494 2 HANDLE GRIP
3 02900 2 ROLL PIN
4 03972 1 COUPLER,3/8FEM. 3/8NPT
5 03973 1 COUPLER,3/8MALE 3/8NPT
6 04058 1 SPRING
7 04077 1 VALVE SPOOL
8 04371 1 TRIGGER
9 04373 4 SIDE ROD
10 04374 4 HEX NUT
11 04379 2 O-RING*
12 04381 2 BACK-UP RING*
13 04382 1 AUTOMATIC VALVE
14 04383 1 FLOW SLEEVE TUBE
15 04571 2 PUSH PIN
16 04605 4 PUSH PIN
17 07479 1 ACCUMULATOR DIAPHRAGM
18 07480 1 AUTOMATIC VALVE BODY
19 07483 1 HANDLE
20 07492 2 ROLL PIN
21 07493 1 O-RING PLUG MALE
22 04057 1 BUSHING (BUSHING ASSY
07699 INCLUDES ITEMS 44-46)
23 09611 1 FLOW SLEEVE
24 09640 1 PORTING BLOCK
25 11588 1 ACCUMULATOR ON-OFF
26 74832 2 STANLEY LOGO
27 19443 1 PISTON
28 20499 1 CHARGE VALVE
30 72919 2 FILLER SNAP-ON SMALL
ITEM P/N QTY DESCRIPTION
31 74662 1 NAME TAG-BR50 T-HANDLE
44 04056 1 ROD WIPER*
45 01362 1 O-RING*
46 00293 1 O-RING*
SEAL KIT P/N-13552
* DENOTES PART IN SEAL KIT
BR50 User Manual ◄ 19
Page 20
21
16
37
43
28
31
39
BR50 ANTI-VIB ILLUSTRATION
PICTURED IS A BR5017801 FOR BREAKER FOOT PARTS THAT
7
42
45
41
17
35
34
30
PERTAIN TO YOUR MODEL SEE PAGE 22 THRU PAGE 26.
15
3
12
10
26
33
46
25
27
50
49
48
18
32
6
4
5
1
2
29
14
20
24
13
44
38
19
8
9
36
9
22
8
3
47
11
NOTE: 5-GPM Models (BR5057801 & BR5057801AA) have a
Orice Plug P/N-12832 Installed in the lower return port of item 24 Accumulator On-Off Valve Block (Orice Plug not pictured).
20 ► BR50 User Manual
See pages 22 thru 26 for Breaker foot parts.
Page 21
BR50 ANTI-VIB PARTS LIST
ITEM P/N QTY DESCRIPTION
1 01652 2 HOSE WHIP 12"
2 02494 2 HANDLE GRIP
3 02900 2 ROLL PIN
4 03972 1 COUPLER,3/8FEM. 3/8NPT
FL.FACE SET 03971
5 03973 1 COUPLER,3/8MALE 3/8NPT
FL.FACE SET 03971
6 04058 1 SPRING
7 04374 4 HEX NUT
8 04379 2 O-RING*
9 04381 2 BACK-UP RING*
10 04382 1 AUTOMATIC VALVE
11 04383 1 FLOW SLEEVE TUBE
12 04571 2 PUSH PIN
13 04605 4 PUSH PIN
14 07479 1 ACCUMULATOR DIAPHRAGM
15 07480 1 AUTOMATIC VALVE BODY
16 07493 1 O-RING PLUG MALE
17 07624 1 ROLL PIN
18 04057 1 BUSHING (BUSHING ASSY
07699 INCLUDES ITEMS 48-50)
19 09611 1 FLOW SLEEVE
20 09640 1 PORTING BLOCK
21 10180 1 CAUTION N2 GAS STICKER
22 11207 1 CIRCUIT TYPE "D" STICKER
11206 1 CIRCUIT TYPE “C” STICKER
(5-GPM MODELs ONLY)
24 11588 1 ACCUMULATOR ON-OFF
VALVE BLOCK
25 74832 2 STANLEY LOGO
26 19443 1 PISTON
58597 1 PISTON (5-GPM MODELS ONLY
BR5057801 & BR5057801AA)
27 20499 1 CHARGE VALVE
28 20500 2 ROLL PIN
29 20505 1 HANDLE PIVOT BLOCK
30 20508 2 PIVOT SCREW
31 20511 1 LEVER
32 20515 1 VALVE SPOOL
33 20517 4 SIDE ROD
ITEM P/N QTY DESCRIPTION
34 20540 2 COMPRESSION COIL SPRING
35 20541 2 COMPRESSION COIL SPRING
36 28322 1 STICKER "CE"
37 28369 1 HANDLE (GUARDED)
38 28409 1 COMPOSITE STICKER
39 28494 1 TOP PLATE
41 58526 1 CAST TRIGGER
42 58527 1 TRIGGER LOCK
43 58529 1 TRIGGER HANDLE
44 65458 1 GUARANTEED SOUND POWER
LEVEL - 104dB (BR5057801)
45 66828 1 TORSION SPRING
46 72919 2 FILLER SNAP-ON SMALL
47 74661 1 NAME TAG-BR50 8-GPM ANTI-
VIB HANDLE
74665 NAME TAG-BR50 5-GPM ANTI_
VIB HANDLE (BR5057801 only)
48 00293 1 O-RING*
49 01362 1 O-RING*
50 04056 1 ROD WIPER*
SEAL KIT P/N-13552
* DENOTES PART IN SEAL KIT
BR50 User Manual ◄ 21
Page 22
BR50 BREAKER FOOT PARTS LIST
BREAKER FOOT ASSEMBLY (STANDARD) P/N-72825 (MODEL BR50120 and BR50125) 72825 Assembly Includes Items 1 thru 14 Below.
ITEM P/N QTY DESCRIPTION
1 01269 2 TAPER SLEEVE
2 01744 1 SPRING
3 01837 1 LATCH
4 02022 1 O-RING*
5 03127 1 ROD WIPER*
6 72825 1 HEX BUSHING 1-1/8" - IF
ORDERING HEX BUSHING YOU MUST ORDER COM­PLETE FOOT ASSY 72825
1-1/8” HEX
INSTALL WITH A LIGHT COATING OF
12
LOCTITE #609 ON I.D. OF FOOT BORE
4
3
ITEM P/N QTY DESCRIPTION
7 04983 1 FOOT LATCH BOLT
8 04984 1 NYLOCK NUT
9 04985 2 SPRING WASHER
10 08411 1 DETENT
11 09642 1 BACK UP WASHER
12 72825 1 INSERT - IF ORDERING IN-
13 72825 1 BREAKER FOOT - IF OR-
14 34092 1 SEAL*
8
SERT YOU MUST ORDER COMPLETE FOOT ASSY 72825
DERING FOOT YOU MUST ORDER COMPLETE FOOT ASSY 72825
1
7
99 1
11
5
INSTALL WITH
6
LOCTITE #609
14
22 ► BR50 User Manual
NOTE: IF YOU ARE REPLACING THE FOOT, HEX BUSHING OR INSERT
2
1013
YOU MUST PURCHASE A COMPLETE BREAKER FOOT ASSEMBLY.
Page 23
BR50 BREAKER FOOT PARTS LIST
BREAKER FOOT ASSEMBLY (EASY RIDE) P/N-72932 (MODEL BR50120E) 72932 Assembly Includes Items 1 thru 17 Below.
ITEM P/N QTY DESCRIPTION
1 01269 2 TAPER SLEEVE
2 01744 1 SPRING
3 01837 1 LATCH
4 02022 1 O-RING*
5 03127 1 ROD WIPER*
6 04983 1 FOOT LATCH BOLT
7 04984 1 NYLOCK NUT
8 04985 2 SPRING WASHER
1-1/8” HEX
ITEM P/N QTY DESCRIPTION
9 72932 1 HEX BUSHING 1-1/8" - IF
ORDERING HEX BUSHING YOU MUST ORDER COM­PLETE FOOT ASSY 72932
10 07522 1 RETAINING RING
11 08115 1 COLLAR SUPPORT ASSY.
12 72932 1 BREAKER FOOT - IF OR-
DERING FOOT YOU MUST ORDER COMPLETE FOOT ASSY 72932
13 08158 1 SPRING
14 08411 1 DETENT
15 09642 1 BACK UP WASHER
16 72932 1 INSERT - IF ORDERING IN-
SERT YOU MUST ORDER COMPLETE FOOT ASSY 72932
17 34092 1 CUP SEAL*
17515
12
INSTALL WITH A
16
LIGHT COATING OF LOCTITE #609 ON I.D. OF FOOT BORE.
9
INSTALL WITH LOCTITE #609
13
2 34
10
1411
7
1 6
8
8
1
ALIGN HEX AS SHOWN
NOTE: IF YOU ARE REPLACING THE FOOT, HEX BUSHING OR INSERT YOU MUST PURCHASE A COMPLETE BREAKER FOOT ASSEMBLY.
BR50 User Manual ◄ 23
Page 24
BR50 BREAKER FOOT PARTS LIST
BREAKER FOOT ASSEMBLY (STANDARD) P/N-72828 (MODELS BR50130 and BR50135) 72828 Assembly Includes Items 1 thru 14 Below.
ITEM P/N QTY DESCRIPTION
1 01269 2 TAPER SLEEVE
2 01744 1 SPRING
3 01837 1 LATCH
4 02022 1 O-RING*
5 03127 1 ROD WIPER*
6 72828 1 HEX BUSHING 1-1/4" - IF
ORDERING HEX BUSHING YOU MUST ORDER COM­PLETE FOOT ASSY 72828
1-1/4” HEX
INSTALL WITH A LIGHT COATING OF
12
LOCTITE #609 ON I.D. OF FOOT BORE
ITEM P/N QTY DESCRIPTION
7 04983 1 FOOT LATCH BOLT
8 04984 1 NYLOCK NUT
9 04985 2 SPRING WASHER
10 08411 1 DETENT
11 09642 1 BACK UP WASHER
12 72828 1 INSERT - IF ORDERING IN-
SERT YOU MUST ORDER COMPLETE FOOT ASSY 72828
13 72828 1 BREAKER FOOT - IF OR-
DERING FOOT YOU MUST ORDER COMPLETE FOOT ASSY 72828
14 34092 1 CUP SEAL*
14511
INSTALL WITH
6
LOCTITE #609
34
8 9
1
9
1
7
NOTE: IF YOU ARE REPLACING THE FOOT, HEX BUSHING OR INSERT
2
1013
YOU MUST PURCHASE A COMPLETE BREAKER FOOT ASSEMBLY.
24 ► BR50 User Manual
Page 25
ALIGN HEX AS SHOWN
BR50 BREAKER FOOT PARTS LIST
BREAKER FOOT ASSEMBLY (EASY RIDE) P/N-72019 (MODEL BR50130E) 72019 Assembly Includes Items 1 thru 17 Below.
ITEM P/N QTY DESCRIPTION
1 01269 2 TAPER SLEEVE
2 01744 1 SPRING
3 01837 1 LATCH
4 02022 1 O-RING*
5 03127 1 ROD WIPER*
6 04983 1 FOOT LATCH BOLT
7 04984 1 NYLOCK NUT
8 04985 2 SPRING WASHER
INSTALL WITH
9
LOCTITE #609
1-1/4” HEX
ITEM P/N QTY DESCRIPTION
9 72019 1 HEX BUSHING 1-1/4" - IF
ORDERING HEX BUSHING YOU MUST ORDER COM­PLETE FOOT ASSY 72019
10 07522 1 RETAINING RING
11 08116 1 COLLAR SUPPORT ASSY.
12 72019 1 BREAKER FOOT - IF OR-
DERING FOOT YOU MUST ORDER COMPLETE FOOT ASSY 72019
13 08158 1 SPRING
14 08411 1 DETENT
15 09642 1 BACK UP WASHER
16 72019 1 INSERT - IF ORDERING IN-
SERT YOU MUST ORDER COMPLETE FOOT ASSY 72019
17 34092 1 CUP SEAL*
4
17 515
12
INSTALL WITH A
16
LIGHT COATING OF LOCTITE #609 ON I.D. OF FOOT BORE.
13
2 3
10
1411
NOTE: IF YOU ARE REPLACING THE
1
1
67 8
8
FOOT, HEX BUSHING OR INSERT YOU MUST PURCHASE A COMPLETE BREAKER FOOT ASSEMBLY.
BR50 User Manual ◄ 25
Page 26
BR50 BREAKER FOOT PARTS LIST
BREAKER FOOT ASSEMBLY (EASY RIDE) UK P/N-48772 (MODELS BR5017801, BR5017801AA, BR5057801 and BR5057801AA) 48772 Assembly Includes Items 1 thru 17 Below.
ITEM P/N QTY DESCRIPTION
1 01269 2 TAPER SLEEVE
2 01744 1 SPRING
3 01837 1 LATCH
4 02022 1 O-RING*
5 03127 1 ROD WIPER*
6 04983 1 FOOT LATCH BOLT
7 04984 1 NYLOCK NUT
8 04985 2 SPRING WASHER
1-1/4” HEX UK AND CE
MODELS
INSTALL WITH
14
LOCTITE #609
ITEM P/N QTY DESCRIPTION
9 07522 1 RETAINING RING
10 08158 1 SPRING
11 08411 1 DETENT
12 09642 1 BACK UP WASHER
13 48772 1 INSERT - IF ORDERING THE IN-
SERT YOU MUST ORDER COM­PLETE FOOT ASSY 48772
14 48772 1 HEX BUSHING 1-1/4" - IF ORDER-
ING HEX BUSHING YOU MUST ORDER COMPLETE FOOT ASSY 48772
15 11234 1 COLLAR SUPPORT ASSY.
16 48772 1 BREAKER FOOT - IF ORDER-
ING BREAKER FOOT YOU MUST ORDER COMPLETE FOOT ASSY 48772
17 34092 1 CUP SEAL*
16 10
17 512 9
INSTALL WITH A
13
LIGHT COATING OF LOCTITE #609 ON I.D. OF FOOT BORE.
2 34
1
1115
67 8 1 8
ALIGN HEX AS SHOWN
NOTE: IF YOU ARE REPLACING THE FOOT, HEX BUSHING OR INSERT YOU MUST PURCHASE A COMPLETE BREAKER FOOT ASSEMBLY.
26 ► BR50 User Manual
Page 27
Page 28
Stanley Hydraulic Tools
3810 SE Naef Road
Milwaukie, Oregon 97267-5698 USA
(503) 659-5660 / Fax (503) 652-1780
www.stanleyhydraulics.com
Loading...