LOOP CALIBRATOR
INSTRUCTION MANUAL
Distributed by: Mitchell Instrument Co. Inc.
Call Toll Free (888) 270 2690 - www.mitchellinstrument.com
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg2.png)
Table of Contents
Introduction..............................................1.
Safety Notes.............................................2.
Features...................................................3.
Specication.............................................4.
Panel Description.....................................5.
Display......................................................6.
Functions.................................................7.
Operating Instruction8.
mA Output Selection............................A.
Percentage(%) Input............................B.
Adjusting the Percentage Up andC.
Down....................................................
Auto Step Function..............................D.
Auto Ramp Function............................E.
0~24V Voltage Output..........................F.
Voltage Output(0-24V)........................G.
Use the AC Adapter..................................9.
Replacing the Battery.............................10.
1
1
1
2
3
4
5-7
8-9
10-11
12-13
14-15
16-17
18
19
20
20
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg3.png)
-1-
Introduction11
This tester has been designed and tested in accordance
with the CE safety requirements for electronic measuring
apparatus EN61326-1 and other safety standards. Follow
all warnings to ensure safe operation.
Safety Notes21
Read the following safety information carefully ●
before attempting to operate or service the
meter.
Use the meter only as specied in this ●
manual. Otherwise, the protection provided
by the meter may be impaired.
Rated enviromental conditions: ●
(1) Indoor use.
(2) Installation Category I
(3) Pollution Degree 2.
(4) Altitude up to 2000 meters.
(5) Relative humidity 80% max.
(6) Ambient temperature 0~40℃.
Features:31
(1) 4-20mA (1KΩ load, 24V Loop Supply)
(2) 0.025% Basic Accuracy
(3) Simple Operation Interface
(4) Auto Ramp and Step Functions
(5) 0-20mA, 0-24mA selectable
(6) Incremental percentage setting: 0-100%
(7) Warning beeper when output is open
(8) 0-24 V output
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg4.png)
-2-
Specication (2541
℃
±5
℃
≤85%R.H.)
DC CURRENT (1kΩ Max Load, 24v Loop Supply)
RANGE RESOLUTION ACCURACY
0-4mA 1uA ±0.025%±10uA
4-20mA 1uA ±0.025%±5uA
20-24mA 1uA ±0.025%±5uA
DC VOLTAGE
RANGE
RESOLUTION ACCURACY
0-4V
1mV ±0.05%±10mV
4-20V
1mV ±0.05%±5mV
20-24V
1mV ±0.05%±5mV
GENERAL
Power Consumption 150mA at 24V 1kΩ load
Operating Temperature 0º C - 50º C
Operating Humidity ≤80% R.H.
Storage Temperature -10º C - 60º C
Storage Humidity ≤85% R.H.
Power Source 9V x 1 alkaline battery
Dimensions 160 (L) x 100 (W) x 38 (D) mm
Weight Approx. 350g (battery includ-
ed)
Accessories DC adapter, pouch, battery,
instruction manual
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg5.png)
-3-
Panel Description51
1.LCD Display 6.ENTER Button
2.ON/OFF Button 7.Numerical & Function Keypad
3.Shift Button 8.DC Adaptor Input Socket
4.Voltage Button 9.Stand
5.Current Button 10.Output Terminal
4-20mA LOOP CALIBRATOR
1 2 3
4-20mA
4
7 8
0
9
V
I
START
5
END
%
%
-
+
6
SEC.
ENTER
Shift
0-20mA 0-24mA
ON
OFF
%
1.
7.
6.
2.
8.
9.
3.
4.
5.
10.
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg6.png)
-4-
Display61
1.mVA: Units
2.0-20mA: Output Range of mA
3.%: Percentage
4. : Ramp
5. : STEP
6.OL: Overload, output open
7.SHIFT:SHIFT functions
8. : low Battery
1.
2. 3.
4.
5.
6.
7.8.
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg7.png)
-5-
Functions71
Power ON/OFFa.
Press the SHIFT button and select the desired mA b.
range by pressing one of these three buttons.
Press the SHIFT button then press START (#4) button c.
to begin Auto Ramp Function.
Press the SHIFT button then press the END (#5) d.
button to stop Auto Ramp Function.
1 2 3
4-20mA
4
7 8
0
9
V
I
START
5
END
%
%
6
SEC.
ENTER
Shift
0-20mA 0-24mA
ON
OFF
%
![](/html/75/75fc/75fc3f1242e486faa4732c10bf6cf28b7ce015bab7063ede3c45d7ab0f53bb85/bg8.png)
-6-
Press the SHIFT button then press the SEC. (#6) e.
button to enter the duration in seconds for Auto Ramp
Function.
Press the SHIFT button then press this button (#7) f.
to begin Auto Ramp Function. Press again to end Auto
Ramp Function.
Press the SHIFT button then press the % button to g.
select the percentage range.
After the percentage range has been entered,use
these / buttons to increase or decrease the
percentage incrementally.
Press the SHIFT button then press this button (#9) to h.
start the STEP function. Press again to stop the function.