Standard 63323, 64218, 64217, 64220, 64219 Installation Instructions Manual

...
LED FLOOD FIXTURES INSTALLATION INSTRUCTIONS
Order code
63323 LED/FL/10W/30K/KN/120-277V/BRZ/STD 120-277 ≥ 0.90 10 3 000 64217 LED/FL/10W/30K/KN/120-277V/WH/STD 120-277 ≥ 0.90 10 3 000 64218 LED/FL/10W/30K/KN/120-277V/BLK/STD 120-277 ≥ 0.90 10 3 000 63324 LED/FL/10W/40K/KN/120-277V/BRZ/STD 120-277 ≥ 0.90 10 4 000 64219 LED/FL/10W/40K/KN/120-277V/WH/STD 120-277 ≥ 0.90 10 4 000 64220 LED/FL/10W/40K/KN/120-277V/BLK/STD 120-277 ≥ 0.90 10 4 000 63325 LED/FL/30W/30K/KN/120-277/BRZ/STD 120-277 ≥ 0.90 30 3 000 63326 LED/FL/30W/40K/KN/120-277/BRZ/STD 120-277 ≥ 0.90 30 4 000 63327 LED/FL/50W/40K/KN/120-277/BRZ/STD 120-277 ≥ 0.90 50 4 000 63328 LED/FL/80W/40K/SF/120-277/BRZ/STD 120-277 ≥ 0.90 80 4 000 63329 LED/FL/100W/40K/SF/120-277/BRZ/STD 120-277 ≥ 0.90 100 4 000 63330 LED/FL/30W/40K/YK/120-277/BRZ/STD 120-277 ≥ 0.90 30 4 000 63331 LED/FL/50W/40K/YK/120-277/BRZ/STD 120-277 ≥ 0.90 50 4 000 63332 LED/FL/80W/40K/YK/120/277/BRZ/STD 120-277 ≥ 0.90 80 4 000 63333 LED/FL/100W/40K/YK/120/277/BRZ/STD 120-277 ≥ 0.90 100 4 000
Description Input
voltage
(VAC)
Power factor
Watts
(W)
Colour
temp.
(K)
IMPORTANT: READ ALL INSTRUCTIONS BEFORE THE INSTALLATION.
NOTE: SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: Risk of re or electric shock. The installation should be performed only by a qualied electrician in accor-
dance with the National Electrical Code and relevant local codes. This product must be installed in full accordance with applicable electrical and building codes.
WARNING - TO AVOID ELECTRIC SHOCK:
• Luminaire must be connected to a wiring system with an equipment-grounding conductor.
WARNING - TO AVOID EXPLOSION:
• Make sure the supply voltage is the same as the rated luminaire voltage.
• Do not install where marked operating temperatures exceed the ignition temperature of the hazardous atmosphere.
• Do not operate in ambient temperatures above those indicated on the luminaire.
• Keep lens tightly closed when in operation.
• For supply connections use wire rated for at least 100°C.
Ø21.5
Ø13.5
Ø6.5
Ø.10
53
120
Ø21.5
83
152
232
35
Ø.10
10 W
30 W
80 W
Ø21.5
210 321
60
Ø.10
Ø21.5
Ø.10
35
Ø.10
100 W
83
152
265
50 W
LED FLOOD FIXTURES INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS: DIRECTLY FIX TO MOUNTING SURFACE
• Use expansion bolts to secure the xture on mounting
1 2
L(BLACK)
N(WHITE)
G(GREEN)
surface (FIG. 1).
• Keep enough length wires to ensure adjusting angle unhindered.
• Connect wires into wiring terminal; white wire to “Neu­tral” terminal, black wire to “Live” terminal, green wire to “Ground”
terminal; and x them by screws.
• Adjust the xture to desired orientation, tighten the
WALL
screws. Use cULus Listed Water-proof outlet box cove (FIG. 2).
INSTALLATION INSTRUCTIONS: KNUCKLE MOUNTING (10 W / 30 W / 50 W )
• Adjust the two screws turn the xture left and right, up and down (FIG. 1).
• Secure service wire or conduit to the wiring compartment cover with 1/2” connector ( not provided ). ). Connect
white xture wire to white supply wire, black xture wire to black supply wire. Service ground should be attached to green ground screw provided. Ground must be properly attached to avoid the risk of electrical shock. Use wire nuts,
crimp-on lugs, or other approved devices to connect all wires. Make sure connections are secure and that no loose wire
strands are sticking out of connectors. Secure wiring compartment cover to xture, with black and white connections inside the wiring compartment. Use UL and CUL Listed exible steel waterproof conduit in trade size 1/2 and cULus
water-proof outlet box cove.(FIG. 2).
1 2
INSTALLATION INSTRUCTIONS: KNUCKLE MOUNTING ( 80 W / 100 W )
• Adjust the xture orientation by turning the bolt (FIG. 1).
• Please use a post of diameter 2.36” for mounting, and tighten with screws (FIG. 2).
• Please drill the holes on the square pole according to the size above (FIG. 3).
• Adjust the xture to desired orientation, tighten the screws (FIG. 3).
1 2 3
Loading...