STAKOHOME KNX - DMX512, BES-GW612100 Programming Manual

Gateways KNX - DMX512
BES-GW612100
v2.1.2
Programming manual
z
DMXBUS-K - Gat eways
Programming manual v2.1.2
www.besknx.cz
2
Index
1 GENERAL DESCRIPTION .......................................................................................................................................... 3
2 TECHNICAL INFORMATION ..................................................................................................................................... 4
3 PROGRAMMING . ................................................................................................................................................... 5
3.1 APPLICATION PROGRAM INFORMATION . .......................................................................................................................... 5
3.2 INDIVIDUAL ADDRESS . ................................................................................................................................................. 5
3.3 RESTORE FACTORY SETTINGS . ........................................................................................................................................ 5
3.4 ADDING DMX LIGHTS ................................................................................................................................................. 6
3.4.1 Device type . ....................................................................................................................................................... 6
3.4.2 Parameters ........................................................................................................................................................ 7
3.5 COMMUNICATION OBJECTS . ......................................................................................................................................... 8
3.5.1 Objects table . .................................................................................................................................................... 8
3.5.2 Objects description . ........................................................................................................................................... 9
3.6 SCENES/ SEQUENCES PROGRAMMING . ........................................................................................................................... 10
3.6.1 How to create a scene . .................................................................................................................................... 10
3.6.2 Nomenclature . ................................................................................................................................................. 10
3.6.3 Commands ...................................................................................................................................................... 11
4 INSTALLATION . .................................................................................................................................................... 12
DMXBUS-K - Gat eways
Programming manual v2.1.2
www.besknx.cz
3
1 General description
The device DMXBUS-K with Ref. GW612100, is a communication gateway between KNX protocol and DMX 512 protocol.
This device allows to regulate the 512 channels supported by DMX protocol and to execute up to 16 scenes, being easily programmable through the projects developing software ETS.
Thanks to this gateway it is possible to develop the integration of a DMX device or system into a KNX home automation installation, and regulate individually each DMX channel in a simply way like any other KNX dimmer or to program a complex group of commands in a scene in order to create sequences.
DMXBUS-K - Gat eways
Programming manual v2.1.2
www.besknx.cz
4
2 Technical information
Main power supply
230Vac
Max. power consumption
2,6VA @ 230Vac
Current consumption
1 mA from KNX BUS
Mounting
DIN rail
Size
6 modules.
Connections
BUS connection terminal KNX. Screw terminals for main supply and DMX bus.
DMX Channels
Up to 512 DMX channels emulation.
Environment temperature range
Operation: -10ºC/55ºC Storage: -30ºC/60ºC Transportation: - 30ºC/60ºC
Regulation
According to the directives of electromagnetic compatibility and low voltage: EN 50090-2-2 / UNE-EN 61000-6-3:2007 / UNE-EN 61000-6-1:2007 / UNE-EN 61010-1.