Stairville Outdoor Stage PAR 12x8 QCL User Manual

Outdoor Stage PAR
12 × 8 QCL
LED PAR
user manual
Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
15.02.2018, ID: 305314 (V4)
Table of contents
1 General notes............................................................................................................................................... 5
1.1 Further information........................................................................................................................... 6
1.2 Notational conventions.................................................................................................................... 7
1.3 Symbols and signal words............................................................................................................... 7
2 Safety instructions.................................................................................................................................. 10
3 Features....................................................................................................................................................... 15
4 Installation.................................................................................................................................................. 17
5 Starting up.................................................................................................................................................. 21
6 Connections and operating elements........................................................................................... 24
7 Operating.................................................................................................................................................... 27
7.1 Starting the device........................................................................................................................... 27
7.2 Main menu.......................................................................................................................................... 27
7.3 Menu overview................................................................................................................................. 35
7.4 Functions in 1-channel DMX mode........................................................................................... 36
7.5 Functions in 4-channel DMX mode........................................................................................... 37
Table of contents
Outdoor Stage PAR 12 × 8 QCL
3
7.6 Functions in 5-channel DMX mode........................................................................................... 38
7.7 Functions in 7-channel DMX mode........................................................................................... 38
8 Technical specifications....................................................................................................................... 41
9 Plug and connection assignments.................................................................................................. 42
10 Troubleshooting...................................................................................................................................... 43
11 Cleaning....................................................................................................................................................... 45
12 Protecting the environment.............................................................................................................. 46
Table of contents
LED PAR
4
1 General notes
This manual contains important instructions for the safe operation of the unit. Read and follow the safety instructions and all other instructions. Keep the manual for future reference. Make sure that it is available to all those using the device. If you sell the unit please make sure that the buyer also receives this manual.
Our products are subject to a process of continuous development. Thus, they are subject to change.
General notes
Outdoor Stage PAR 12 × 8 QCL
5
1.1 Further information
On our website (www.thomann.de) you will find lots of further information and details on the following points:
Download This manual is also available as PDF file for you to download.
Keyword search
Use the search function in the electronic version to find the topics of interest for you quickly.
Online guides
Our online guides provide detailed information on technical basics and terms.
Personal consultation For personal consultation please contact our technical hotline.
Service
If you have any problems with the device the customer service will gladly assist you.
General notes
LED PAR
6
1.2 Notational conventions
This manual uses the following notational conventions:
The letterings for connectors and controls are marked by square brackets and italics. Examples: [VOLUME] control, [Mono] button.
Texts and values displayed on the device are marked by quotation marks and italics.
Examples: ‘24ch’ , ‘OFF’.
1.3 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal words that are used in this manual.
Letterings
Displays
General notes
Outdoor Stage PAR 12 × 8 QCL
7
Signal word Meaning DANGER! This combination of symbol and signal word indicates an
immediate dangerous situation that will result in death or serious injury if it is not avoided.
WARNING! This combination of symbol and signal word indicates a pos-
sible dangerous situation that can result in death or serious injury if it is not avoided.
NOTICE! This combination of symbol and signal word indicates a pos-
sible dangerous situation that can result in material and environmental damage if it is not avoided.
Warning signs Type of danger
Warning – high-voltage.
Warning – hot surface.
General notes
LED PAR
8
Warning signs Type of danger
Warning – suspended load.
Warning – danger zone.
General notes
Outdoor Stage PAR 12 × 8 QCL
9
2 Safety instructions
This device is intended to be used as an electronic illumination effect using LED technics. The device is designed for professional use and is not suitable for use in households. Use the device only as described in this user manual. Any other use or use under other operating con­ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.
Intended use
Safety instructions
LED PAR
10
DANGER! Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
DANGER! Electric shock caused by short-circuit
Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a registered electrician.
Safety
Safety instructions
Outdoor Stage PAR 12 × 8 QCL
11
DANGER! Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never remove any covers.
There are no user-serviceable parts inside. Do not use the device if covers, protectors or optical components are missing or
damaged.
WARNING! Eye damage caused by high light intensity
Never look directly into the light source.
Safety instructions
LED PAR
12
WARNING! Risk of epileptic shock
Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights.
WARNING! Risk of burns
The surface of the device can become very hot during operation. Do not touch the device with bare hands during operation, and after switching
off wait for at least 15 minutes.
NOTICE! Risk of fire
Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames.
Safety instructions
Outdoor Stage PAR 12 × 8 QCL
13
NOTICE! Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker. Failure to do so could result in damage to the device and possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire.
Safety instructions
LED PAR
14
3 Features
Due to its sturdy and weather-proof housing made of die-cast aluminum, the device is espe­cially suitable for outdoor use. With the very bright four-colour LEDs, it is particularly suitable for professional lighting tasks.
Special features of the device:
n
12 × four-colour LEDs (8 W)
n
Control via DMX (four different modes) and via buttons and display on the unit
n
11 preprogrammed automatic shows
n
Master / Slave operation
n
Rugged die-cast aluminium housing
n
IP65 (suitable for outdoor use)
n
Pressure equalisation element (prevents the development of condensation inside the device)
n
Sturdy double bracket for secure attachment to trusses or firm footing on the ground
n
Connectors for power supply and DMX control via splashproof screw-mountable plugs and couplings
n
Mains power adapter with safety plug included
Features
Outdoor Stage PAR 12 × 8 QCL
15
Loading...
+ 33 hidden pages