3 Operation
Charging station ATS-16PS:
Connect the power supply unit to the
jack DC IN situated on the side of the
charging station, then connect it to a
mains socket. Thus, the charging station is switched on.
Charging case ATS-36C:
1) To open the case, press the grey buttons to unlock the two snap locks and
pull the locks towards you.
2) Connect the power supply unit fastened
in the case with V elcro to the jack DC IN
above it; then connect it to a mains
socket via the supplied mains cable.
The power LED on the power supply
unit will light up.
3) To switch on the charging case, set the
switch next to the jack DC IN to ON
(switch will light up).
After switching on, the LED OK and the LED
ON at each charging compartment will shortly
light up in succession. The charger will perform
a short self-test. At its end, the LEDs ON of the
charging compartments will shortly light up
again: The charger is now ready for operation.
4 Charging the Batteries
1) Insert the units (transmitters or receivers)
with their batteries into the charging compartments.
2) During the charging process, the orange
LED ON for the corresponding charging
compartment will light up. (If the LED
flashes, the batteries are not correctly inserted into the transmitter/receiver or nonrechargeable batteries are used instead of
rechargeable batteries – in this case,
remove the unit from the compartment
immediately.)
3) When the batteries of a unit are fully
charged, the green LED OK of the charging compartment will light up.
4) To switch off
the charging station ATS-16PS, discon-
nect the power supply unit from the
mains socket. The LEDs ON will
shortly light up.
the charging case A TS-36C, set the switch
to OFF. The switch illumination will be
extinguished and the LEDs ON will
shortly light up. If the case is not used
for charging, disconnect the power
supply unit from the mains to prevent
unnecessary power consumption.
To close the case, fold down the
cover first; then push the snap locks
back into their locking position. Lock
the case with the one of the keys supplied, if required.
Note: When the charger is disconnected
from the power supply, allow the unit to reset
for 5s before operating it again.
5 Specifications
Charging procedure: pulse charging with ∆V and
timer control
Charging current: . . 450 –500 mA (ATS-16PS)
300– 330 mA (ATS-36C)
Charging time*: . . . . approx. 3 –4 hours (ATS-16PS)
approx. 5– 6 hours (ATS-36C)
Ambient temperature: 0 – 40 °C
Power supply
ATS-16PS: . . . . . 12V /500 mA via supplied
power supply unit connected
to 230V~ / 50Hz
ATS-36C: . . . . . . 12 V /7A via supplied switch
mode power supply unit con-
nected to 100– 240 V~ /50 Hz
or 60Hz
Dimensions, weight
ATS-16PS: . . . . . 105 x 72 x 84mm, 168 g
ATS-36C: . . . . . . 86 x 23 x 35 cm, 9.6kg
* for NiMH rechargeable batteries 1300mAh
Subject to technical modification.
7
GB
All rights reserved by MONACOR®INTERNATIONAL GmbH & Co. KG. No part of this instruction
manual may be reproduced in any form or by any means for any commercial use.