Staco Energy Variable Transformers Selection Guide

Variable Transformers Product Selector Guide
Product Quick Selector
See legend on last page.
The STACO Variable Transformer Product Quick Selector is a guide to all standard single-phase and three-phase vari­able transformers in the Staco product line including portable, ganged and motorized models. Units are listed by voltage rating and by increasing values of current and KVA.
With known values of voltage, current and frequency, the STACO Variable Transformer Selector can be used to locate the particular transformer that best fits your requirements. If a
motor driven model is ordered, be sure to prefix the part num­ber with the desired travel time, typically 5, 15, 30 or 60 sec­onds.
For non-standard operating conditions, refer to the Product Design and Engineering Section of this catalog.
Ratings and configurations not included in the Variable Transformer Selector may be obtained by consulting our STACO representative or by contacting the factory.
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
SINGLE PHASE
50/60 0-120 1.75 0.21 2.2 0.26
171 10
60 0-132 1.75 0.23
50/60 0-120 2.00 0.24 2.5 0.30
201 10
60 0-132 2.00 0.26
50/60 0-120 2.50 0.30 3.2 0.38 221-B
——10
60 0-132 2.50 0.33 3PN221B
50/60 0-120 3.00 0.36 3.5 0.42
291 11
60 0-132 3.00 0.40
50/60
0-120 5.0 0.60 7.0 0.84 501-B, 511 M501-B 5,15,30,60
12
0-140 5.0 0.70 3PN501B
50/60
0-120 10 1.20 13 1.56 1010B M1010B 5,15,30,60
14
0-140
10 1.40 3PN1010B
60 0-120 12 1.44 15 1.80
1210B M1210B 5,15,30,60
17
3PN1210B
0-120 15 1.80 20 2.40 1510 M1510B 5,15,30,60
18
0-140 15 2.10 3PN1510B — 0-140 22 3.08 3PN2210B 20
——
120 0-120 25 3.00 30 3.60
2510 M2510
5,15,30,60
20
0-140 25 3.50 — 0-120 50 6.00 60 7.20
2510-2• M2510-2• 5,15,30,60 20
0-140 50 7.00 — 0-140 50 7.00 5011 M5011 5,15,30,60 22 0-120 60 7.20
6011 M6011 5,15,30,60 30
0-140 60 8.40 — 0-120 75 9.00 90 10.80
2510-3•• M2511-3•• 5,15,30,60 20
0-140 75 10.50 — 0-140 100 14.00 5011-2P M5011-2P 5,15,30,60 22 0-120 120 14.40
6011-2P M6011-2P 5,15,30,60 30
50/60 0-140 120 16.80
0-140 150 21.00 5011-3P M5011-3P 5,15,30,60 22 0-120 180 21.60
6011-3P M6011-3P 5,15,30,60 30
0-140 180 25.20 — 0-140 200 28.00 5011-4P M5011-4P 15,30,60 23 0-120 240 28.80
6011-4P M6011-4P 15,30,60 31
0-140 240 33.60 — 0-140 250 35.00 5011-5P M5011-5P 15,30,60 23 0-120 300 36.00
6011-5P M6011-5P 15,30,60 31
0-140 300 42.00 — 0-140 300 42.00 5011-6P M5011-6P 15,30,60 23 0-140 350 49.00 5011-7P M5011-7P 30, 60 24 0-120 360 43.20
6011-6P M6011-6P 15,30,60 31
0-140 360 50.40 — 0-140 400 56.00 5011-8P M5011-8P 30, 60 24 0-120 420 50.40
6011-7P M6011-7P 30, 60 32
0-140 420 58.80
Product Quick Selector
See legend on last page.
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
SINGLE
PHASE
SINGLE Ø VOLTAGE DOUBLERSSINGLE PHASE
0-140 450 63.00 5011-9P M5011-9P 30, 60 24 0-120 480 57.60
6011-8P M6011-8P 30, 60 32
120 50/60 0-140 480 67.20
0-120 540 64.80
6011-9P M6011-9P 30, 60 32
0-140 540 75.60
3.50
0.42 1020B M1020B 5,15,30,60 14
9.50
1.14 1520 M1520 5,15,30,60 18
10
1.20 2520 M2520 5,15,30,60 20
20
2.40 2520-2• M2520-2• 5,15,30,60 20
28
3.40 5021 M5021 5,15,30,60 22
30
3.60 2520-3 M2520-3 5,15,30,60 20
35
4.20 6020 M6020 5,15,30,60 30
56
6.80 5021-2P M5021-2P 5,15,30,60 22
70
8.40 6020-2P M6020-2P 5,15,30,60 30
84
10.20 5021-3P M5021-3P 5,15,30,60 23
120 50/60 0-280 105
12.60 6020-3P M6020-3P 5,15,30,60 31
112
13.50 5021-4P M5021-4P 15, 30, 60 23
140
16.80 6020-4P M6020-4P 15, 30, 60 31
168
20.40 5021-6P M5021-6P 15, 30, 60 24
175
21.00 6020-5P M6020-5P 15, 30, 60 31
196
23.50 5021-7P M5021-7P 30, 60 24
210
25.20 6020-6P M6020-6P 15, 30, 60 32
224
26.90 5021-8P M5021-8P 30, 60 24
245
29.40 6020-7P M6020-7P 30, 60 32
252
30.20 5021-9P M5021-9P 30, 60 24
280
33.60 6020-8P M6020-8P 30, 60 32
315
37.80 6020-9P M6020-9P 30, 60 32
50/60
0-240 0.80 0.19 1.00 0.24
252 10
0-264 0.80 0.21
50/60 0-240 1.75 0.42 2.20 0.53
171-2 10
60 0-264 1.75 0.46
50/60 0-240 2.00 0.48 2.50 0.60
201-2 10
60 0-264 2.00 0.53
50/60 0-240 2.50 0.60 3.20 0.77
221-B-2 10
60 0-264 2.50 0.66
50/60 0-240 3.00 0.72 3.50 0.84
291-2 11
60 0-264 3.00 0.79
50/60
0-240 3.50 0.84 5.0 1.20 1020B M1020B 5,15,30,60
14
0-280 3.50 0.98 3PN1020B
50/60
0-240 5.00 1.20 7.00 1.68
501-B-2 M501-B-2 5,15,30,60 12
0-280 5.00 1.40
240
60 0-240 5.00 1.20 7.00 1.68
1220B M1220B 5,15,30,60
17
3PN1220B
50/60
0-240 9.50 2.28 12.00 2.88 1520 M1520 5,15,30,60
18
0-280 9.50 2.66 3PN1520B
50/60
0-240 10 2.40 13 3.12
1010B-2 M1010B-2 5,15,30,60 14
0-280 10 2.80
50/60
0-240 10 2.40 13 3.12 2520 M2520 5,15,30,60
20
0-280
10 2.80 3PN2520B
60 0-240 12 2.88 15 3.60 1210B-2 M1210B-2 5,15,30,60 17
50/60
0-240 15 3.60 20 4.80
1510-2 M1510-2 5,15,30,60 18
0-280 15 4.20
50/60
0-240 20 4.80 26 6.20
2520-2• M2520-2• 5,15,30,60 20
0-280 20 5.60
50/60
0-240 25 6.00 30 7.20
2510-2 M2510-2 5,15,30,60 20
0-280 25 7.00
50/60
0-240 28 6.70
5021 M5021 5,15,30,60 22
0-280 28 7.80
Product Quick Selector
See legend on last page.
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
SINGLE PHASE
50/60
0-240 30 7.20 39 9.40
2520-3•• M2520-3•• 5,15,30,60 20
0-280 30 8.40
50/60
0-240 35 8.40
6020 M6020 5,15,30,60 30
0-280 35 9.80
50/60 0-280 50 14.00 5011-2S M5011-2S 5,15,30,60 22 50/60
0-240 56 13.40
5021-2P M5021-2P 5,15,30,60 22
0-280 56 15.70
50/60
0-240 60 14.40
6011-2S M6011-2S 5,15,30,60 30
0-280 60 16.80
50/60
0-240 70 16.80
6020-2P M6020-2P 5,15,30,60 30
0-280 70 19.60
50/60
0-240 84 20.20
5021-3P M5021-3P 5,15,30,60 23
0-280 84 23.50
50/60
0-240 105 25.20
6020-3P M6020-3P 5,15,30,60 31
0-280 105 29.40
50/60
0-240 112 26.90
5021-4P M5021-4P 15, 30, 60 23
0-280 112 31.40 — 0-240 120 28.80
6011-4PS M6011-4PS 15, 30, 60 31
0-280 120 33.60 — 0-240 140 33.60
6020-4P M6020-4P 15, 30, 60 31
0-280 140 39.20 — 0-280 150 42.00 5011-6PS M5011-6PS 15, 30, 60 23 0-240 168 40.30
5021-6P M5021-6P 15, 30, 60 24
0-280 168 47.00 — 0-240 175 42.00
6020-5P M6020-5P 15, 30, 60 31
240 0-280 175 49.00
0-240 180 43.20
6011-6PS M6011-6PS 15, 30, 60 31
0-280 180 50.40 — 0-240 196 47.00
5021-7P M5021-7P 30, 60 24
0-280 196 54.90 — 0-240 210 50.40
6020-6P M6020-6P 15, 30, 60 32
0-280 210 58.80 — 0-240 224 53.80
5021-8P M5021-8P 30, 60 24
0-280 224 62.70
50/60 0-240 240 57.60
6011-8PS M6011-8PS 30, 60 32
0-280 240 67.20 — 0-240 245 58.80
6020-7P M6020-7P 30, 60 32
0-280 245 68.60 — 0-280 250 70.00 M5011-10PS 30, 60 24 0-240 252 60.50
5021-9P M5021-9P 30, 60 24
0-280 252 70.60 — 0-240 280 67.20
6020-8P M6020-8P 30, 60 32
0-280 280 78.40 — 0-240 300 72.00
M6011-10PS 30, 60 32
0-280 300 84.00 — 0-240 315 75.60
6020-9P M6020-9P 30, 60 32
0-280 315 88.20 — 0-240 360 86.40
M6011-12PS 30, 60 33
0-280 360 100.80 — 0-240 420 100.80
M6011-14PS 60 33
0-280 420 117.60 — 0-240 480 115.20
M6011-16PS 60 33
0-280 480 134.40 — 0-240 540 129.60
M6011-18PS 60 33
0-280 540 151.20
3.50
0.84 1020B-2 M1020B-2 5,15,30,60 14
9.50
2.28 1520-2 M1520-2 5,15,30,60 18
240 50/60 0-560 10
2.40 2520-2 M2520-2 5,15,30,60 20
28
6.80 5021-2S M5021-2S 5,15,30,60 22
35
8.40 6020-2S M6020-2S 5,15,30,60 30
1 PHASE V.
DOUBLERS
Product Quick Selector
See legend on last page.
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
SINGLE PHASE
VOLTAGE DOUBLERS
SINGLE PHASE
56
13.50 5021-4PS M5021-4PS 15, 30, 60 23
70
16.80 6020-4PS M6020-4PS 15, 30, 60 31
84
20.40 5021-6PS M5021-6PS 15, 30, 60 24
105
25.20 6020-6PS M6020-6PS 15, 30, 60 32
112
26.90 5021-8PS M5021-8PS 30, 60 24
140
33.60 6020-8PS M6020-8PS 30, 60 32
168
40.30 M5021-12PS 30, 60 25
240 50/60 0-560 175
42.00 M6020-10PS 30, 60 33
196
47.10 M5021-14PS 60 25
210
50.40 M6020-12PS 30, 60 33
224
53.80 M5021-16PS 60 25
245
58.80 M6020-14PS 60 33
252
60.50 M5021-18PS 60 25
280
67.20 M6020-16PS 60 33
315
75.60 M6020-18PS 60 33
50/60
0-480 0.80 0.38 1.00 0.48
252-2 10
0-528 0.80 0.42
50/60
0-480 3.50 1.68 5.00 2.40
1020B-2 M1020B-2 5,15,30,60 14
0-560 3.50 1.96
60 0-480 5.00 2.40 7.00 3.36 1220B-2 M1220B-2 5,15,30,60 17
0-480 9.50 4.56 12 5.76
1520-2 M1520-2 5,15,30,60 18
0-560 9.50 5.32 — 0-480 10 4.80 13 6.24
2520-2 M2520-2 5,15,30,60 20
0-560 10 5.60 — 0-480 28 13.50
5021-2S M5021-2S 5,15,30,60 22
0-560 28 15.70 — 0-480 35 16.80
6020-2S M6020-2S 5,15,30,60 30
0-560 35 19.60 — 0-480 56 26.90
5021-4PS M5021-4PS 15, 30, 60 23
0-560 56 31.40 — 0-480 70 33.60
6020-4PS M6020-4PS 15, 30, 60 31
0-560 70 39.20 — 0-480 84 40.30
5021-6PS M5021-6PS 15, 30, 60 24
0-560 84 47.00
480 0-480 105 50.40
6020-6PS M6020-6PS 15, 30, 60 32
0-560 105 58.80 — 0-480 112 53.80
5021-8PS M5021-8PS 30, 60 24
0-560 112 62.70
50/60 0-480 140 67.20
6020-8PS M6020-8PS 30, 60 32
0-560 140 78.40 — 0-480 168 80.60
M5021-12PS 30, 60 25
0-560 168 94.10 — 0-480 175 84.00
M6020-10PS 30, 60 33
0-560 175 98.00 — 0-480 196 94.10
M5021-14PS 60 25
0-560 196 109.80 — 0-480 210 100.80
M6020-12PS 30, 60 33
0-560 210 117.60 — 0-480 224 107.50
M5021-16PS 60 25
0-560 224 125.50 — 0-480 245 117.60
M6020-14PS 60 33
0-560 245 137.20 — 0-480 252 121.00
M5021-18PS 60 25
0-560 252 141.00 — 0-480 280 134.40
M6020-16PS 60 33
0-560 280 156.80 — 0-480 315 151.20
M6020-18PS 60 33
0-560 315 176.40
Product Quick Selector
See legend on last page.
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
THREE PHASE OPEN DELTA
VOLTAGE DOUBLERS
THREE PHASE OPEN DELTA
3.50
0.73 1020B-2 M1020B-2 5,15,30,60 14
9.50
1.98 1520-2 M1520-2 5,15,30,60 18
10
2.10 2520-2 M2520-2 5,15,30,60 20
28
5.80 5021-2D M5021-2D 5,15,30,60 22
35
7.30 6020-2D M6020-2D 5,15,30,60 30
56
11.80 5021-4D M5021-4D 15, 30, 60 23
70
14.50 6020-4D M6020-4D 15, 30, 60 31
84
17.60 5021-6D M5021-6D 15, 30, 60 24
105
21.80 6020-6D M6020-6D 15, 30, 60 32
120 50/60 0-280 112
23.30 5021-8D M5021-8D 30, 60 24
140
29.10 6020-8D M6020-8D 30, 60 32
175
36.30 M6020-10D 30, 60 32
196
40.80 M5021-14D 60 25
210
43.60 M6020-12D 30, 60 33
224
46.60 M5021-16D 60 25
245
50.90 M6020-14D 60 33
252
52.50 M5021-18D 60 25
280
58.10 M6020-16D 60 33
315
94.50 M6020-18D 60 33
0-240 0.80 0.33 1.00 0.42
252-2 10
50/60
0-264 0.80 0.37 — 0-240 3.50 1.45 5.00 2.08
1020B-2 M1020B-2 5,15,30,60 14
0-280 3.50 1.70
60 0-240 5.00 2.08 7.00 2.91 1220B-2 M1220B-2 5,15,30,60 17
0-240 9.50 3.95 12 5.00
1520-2 M1520-2 5,15,30,60 18
0-280 9.50 4.61 — 0-240 10 4.20 13 5.40
2520-2 M2520-2 5,15,30,60 20
0-280 10 4.85 — 0-240 28 11.60
5021-2D M5021-2D 5,15,30,60 22
0-280 28 13.60 — 0-240 35 14.50
6020-2D M6020-2D 5,15,30,60 30
0-280 35 16.90 — 0-240 56 23.30
5021-4D M5021-4D 15, 30, 60 23
0-280 56 27.20 — 0-240 70 29.10
6020-4D M6020-4D 15, 30, 60 31
0-280 70 33.90 — 0-240 84 34.90
5021-6D M5021-6D 15, 30, 60 24
240 0-280 84 40.70
0-240 105 43.60
6020-6D M6020-6D 15, 30, 60 32
0-280 105 50.90 — 0-240 112 46.60
5021-8D M5021-8D 30, 60 24
50/60 0-280 112 54.30
0-240 140 58.10
6020-8D M6020-8D 30, 60 32
0-280 140 67.80 — 0-240 175 72.70
M6020-10D 30, 60 32
0-280 175 84.80 — 0-240 196 81.50
M5021-14D 60 25
0-280 196 95.10 — 0-240 210 87.20
M6020-12D 30, 60 33
0-280 210 101.70 — 0-240 224 93.10
M5021-16D 25
0-280 224 108.60 — 0-240 245 101.70
M6020-14D 60 33
0-280 245 118.70 — 0-240 252 104.50
M5021-18D 60 25
0-280 252 122.20 — 0-240 280 116.30
M6020-16D 60 33
0-280 280 135.60 — 0-240 315 130.80
M6020-18D 60 33
0-280 315 152.60
Product Quick Selector
See legend on last page.
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
THREE PHASE WYE V OL T AGE DOUBLERS
THREE PHASE WYE
60 0-240 1.75 0.73 2.20 0.92 171-3 10 60 0-240 2.00 0.83 2.50 1.04 201-3 10 60 0-240 2.50 1.04 3.20 1.33 221-B-3 10 60 0-240 3.00 1.25 3.50 1.45 291-3 11
50/60 0-240 5.00 2.08 7.00 2.91
501-B-3 M501-B-3 5,15,30,60 12
60 0-280 5.00 2.43
50/60 0-240 10 4.16 13 5.40
1010B-3 M1010B-3 5,15,30,60 14
60 0-280 10 4.85 — 60 0-240 12 4.96 15 6.24 1210B-3 M1210B-3 5,15,30,60 17
50/60 0-240 15 6.22 20 8.30
1510-3 M1510-3 5,15,30,60 18
60 0-280 15 7.26
50/60 0-240 25 10.40 30 12.50
2510-3 M2510-3 5,15,30,60 20
60 0-280 25 12.10
0-280 50 24.20 5011-3Y M5011-3Y 5,15,30,60 22 0-240 60 24.90
6011-3Y M6011-3Y 5,15,30,60 30
0-280 60 29.10 — 0-280 100 48.50 5011-6Y M5011-6Y 15, 30, 60 23 0-240 120 49.80
6011-6Y M6011-6Y 15, 30, 60 31
240 0-280 120 58.10
0-280 150 72.50 5011-9Y M5011-9Y 30, 60 24 0-240 180 74.70
6011-9Y M6011-9Y 30, 60 32
0-280 180 87.20 — 0-280 200 96.70 M5011-12Y 30, 60 25 0-240 240 99.60
M6011-12Y 30, 60 33
0-280 240 116.30
60 0-280 250 121.00 M5011-15Y 60 26
0-240 300 124.60
M6011-15Y 60 34
0-280 300 145.30 — 0-240 360 149.50
M6011-18Y 60 34
0-280 360 174.40 — 0-280 400 193.70 M5011-24Y 60 26 0-240 420 174.40
M6011-21Y 60 34
0-280 420 203.40 — 0-280 450 218.40 M5011-27Y 60 26 0-240 480 199.30
M6011-24Y 60 34
0-280 480 232.50 0-240 540 224.20
M6011-27Y 60 34
0-280 540 261.60
3.50
1.46 1020B-3 M1020B-3 5,15,30,60 14
9.50
3.96 1520-3 M1520-3 5,15,30,60 18
10
4.20 2520-3 M2520-3 5,15,30,60 20
28
11.80 5021-3Y M5021-3Y 5,15,30,60 23
35
14.50 6020-3Y M6020-3Y 5,15,30,60 31
56
23.50 5021-6Y M5021-6Y 15, 30, 60 24
70
29.10 6020-6Y M6020-6Y 15, 30, 60 32
84
35.00 5021-9Y M5021-9Y 30, 60 24
105
43.60 6020-9Y M6020-9Y 30, 60 32
112
46.60 M5021-12Y 30, 60 25
240 60 0-560 140
58.10 M6020-12Y 30, 60 34
168
70.00 M5021-18Y 60 26
175
72.70 M6020-15Y 60 34
196
82.00 M5021-21Y 60 26
210
87.20 M6020-18Y 60 34
224
93.00 M5021-24Y 60 26
245
101.70 M6020-21Y 60 34
252
105.00 M5021-27Y 60 26
280
116.30 M6020-24Y 60 34
315
130.80 M6020-27Y 60 34
Product Quick Selector
INPUT OUTPUT
MANUALLY MOTOR
CONST ANT CONST ANT OPERA TED DRIVEN
CURRENT IMPEDANCE
DET AILED
LOAD
LOAD
TECHNICAL
VOLTS HERTZ VOLTS
AVAILABLE
INFO
PART PART
SPEEDS
PAGE
MAX MAX MAX MAX
NUMBER NUMBER
(sec. at 60 Hz*)
AMPS kVA AMPS kVA
THREE PHASE WYE
50/60 0-480 0.80 0.67 1.00 0.83 252-3
——
10
60 0-528 0.80 0.73
50/60 0-480 3.50 2.91 5.00 4.16
1020B-3 M1020B-3 5,15,30,60 14
60 0-560 3.50 3.40 — 60 0-480 5.00 4.16 7.00 5.82 1220B-3 M1220B-3 5,15,30,60 17
50/60 0-480 9.50 7.90 12 10
1520-3 M1520-3 5,15,30,60 18
60 0-560 9.50 9.21
50/60 0-480 10 8.30 13 10.81
2520-3 M2520-3 5,15,30,60 20
60 0-560 10 9.70
50/60 0-480 28 23.30
5021-3Y M5021-3Y 5,15,30,60 23
60 0-560 28 27.20
50/60 0-480 35 29.10
6020-3Y M6020-3Y 5,15,30,60 31
60 0-560 35 33.90
50/60 0-480 56 46.60
5021-6Y M5021-6Y 15, 30, 60
24
60 0-560 56 54.30
50/60 0-480 70 58.10
6020-6Y M6020-6Y 15, 30, 60 32
60 0-560 70 67.80
50/60 0-480 84 69.80
5021-9Y M5021-9Y 30, 60 24
60 0-560 84 81.50
50/60 0-480 105 87.20
6020-9Y M6020-9Y 30, 60 32
60 0-560 105 101.70
480 50/60 0-480 112 93.10
M5021-12Y 30, 60 25
60 0-560 112 108.60
50/60 0-480 140 116.30
M6020-12Y 30, 60 34
60 0-560 140 135.60
50/60 0-480 168 139.50
M5021-18Y 60 26
60 0-560 168 163.30
50/60 0-480 175 145.30
M6020-15Y 60 34
60 0-560 175 169.50
50/60 0-480 196 163.0
M5021-21Y 60 26
60 0-560 196 189.5
50/60 0-480 210 174.60
M6020-18Y 60 34
60 0-560 210 203.40
50/60 0-480 224 186.50
M5021-24Y 60 26
60 0-560 224 217.80
50/60 0-480 245 203.40
M6020-21Y 60 34
60 0-560 245 237.40
50/60 0-480 252 209.50
M5021-27Y 60 26
60 0-560 252 244.00
50/60 0-480 280 232.50
M6020-24Y 60 34
60 0-560 280 271.30
50/60 0-480 315 261.60
M6020-27Y 60 34
60 0-560 315 305.20
Models with 575V input and 0-575V output are available with Series 6020 variable transformers with a Y, S, or PS suffix. See pages 30, 31, 32, 33 & 34.
Constant Current Load — the normal rated output amperes may be drawn at any position of the brush except in voltage doubler connections. Constant Impedance Load — an increased current may be drawn at the maximum voltage output (Limited to line voltage) provided the current reduces
proportionally as output voltage is lowered.
Voltage Doubler (half rates voltage input). Normal rated amperes may be drawn from 0 to 125% of the input voltage. At outputs above this, the load cur-
rent must be reduced according to the derating guide.Figure B, page 6.
Cord and plug models wired this way at the factory
One 52LAC paralleling choke is required
•• Three 52LAC paralleling chokes are required.
* Speeds are approximately 20% slower at 50Hz.
Loading...