The Staco V features a eld-proven Digital Signal Processor (DSP) achieving high reliability, while providing
protection from electrical power disturbances to the connected load. The convertible tower/rack design oers
maximum exibility, enabling UPS integration into a wide variety of environments.
Industry-leading functionality is standard and includes hot swappable battery, powerful internal charger,
emergency shut-down and programmable receptacles. The Staco V is an ideal power protection solution for
servers, networks, telecommunications, industrial equipment, and manufacturing processes. XL Models are for
those critical applications that require extended battery backup times.
True Double-Conversion
On-Line UPS
n
A true double conversion UPS will provide
clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer center servers,
telecom applications, as well as for industrial applications.
Output Power Factor 0.9
n
Staco V Series is a high-density UPS with an output power factor 0.9 to provide higher performance and eciency to critical
applications.
User-Friendly and Easy-Shift LCD Display
n
The front panel digital display can be easily shifted through LCD setting to suit the installation format,
Tower or Rack mount
Rack/Tower Design
n
The Series V is designed in a true universal-mount case. It can be easily installed as a free-standing tower or in a 19-inch rackmount
conguration.
Programmable Power Management Outlets
n
With programmable power management outlets, users can easily and independently control load segments. During power failure,
this feature enables users to extend battery time to mission-critical devices by shutting down the non-critical devices.
50/60 Hz Frequency Converter Mode
n
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipment.
ECO and Advanced ECO Mode for Energy Saving
n
It allows the UPS to operate in high eciency up to 97% in energy-saving ECO mode. In this operation mode, load is supplied
by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected
systems. The Series V even oers advanced ECO mode to allow UPS to operate at higher eciency up to 98%.
Emergency Power O Function (EPO)
n
This feature can secure the personnel and equipment in case of res or other emergencies.
Hot-Swappable Battery Design
n
Ensures clean and uninterruptible power to protected equipment during battery replacement.
Your Tailored Power Solutions Provider
TM
Page 2
On-Line, Single Phase
UPS System
The Staco V represents the latest in single-phase
technology at an aordable price. Its true on-line
performance provides a constant clean, steady sine wave
safeguarding the most sensitive equipment.
Staco V Series, Universal Rack/Tower Mount
120VAC, 1000VA, 1500VA, 2000VA & 3000VA
& LB Models, 900VA, 1250VA, 1700VA & 2500VA
UPS On-line, Double-Conversion – LCD Panel, USB and RS-232 Standard
Model
(Part Number)
V1000RT120
(SCV-10001)
V1500RT120
(SCV-15001)
V2000RT120
(SCV-20001)
V3000RT120
(SCV-30001)
V1000RTXL120
(SCV-10001-LB)
V1500RTXL120
(SCV-15001-LB)
V2000RTXL120
(SCV-20001-LB)
V3000RTXL120
(SCV-30001-LB)
Standard Models: Maximum (1) External Battery Pack (V1000EBC, V1500EBC, V2000EBC or V3000EBC)
XL Models: Maximum (5) External Battery Pack (V1000EBC, V1500EBC, V2000EBC or V3000EBC)
Note: 1. XL Models do not have internal batteries.
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
2. Unit ships with bundled NetAgent 9 Shutdown Software.
3. All units ship with floor stand and rack mount hardware.
VA/
Watts
1000VA / 900W 45-15P(4) 5-15R
1500VA / 1350W 45-15P(4) 5-15R
2000VA / 1800W 45-20P(8) 5-20R
3000VA / 2700W 4L5-30P
900VA / 810W05-15P(4) 5-15R
1250VA / 1125W05-15P(4) 5-15R
1700VA /1530W05-20P(8) 5-20R
2500VA / 2250W0L5-30P
Internal
Battery
(Minutes)
Input
Cord
Output
Connection
(4) 5-20R &
(1) L5-30R
(4) 5-20R &
(1) L5-30R
*Dimensions
H" x W" x D" / [mm]
3.39" x 17.24" x 16.44" (2U)
[86.2 x 438.0 x 417.5]
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
3.39" x 17.24" x 27.74" (2U)
[86.2 x 438.0 x 704.6]
3.39" x 17.24" x 16.44" (2U)
[86.2 x 438.0 x 417.5]
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
3.39" x 17.24" x 27.74" (2U)
[86.2 x 438.0 x 704.6]
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC
Optional SNMP CardPower management from SNMP manager and web browser
Optional MODBUS CardCommunications from MODBUS
Optional AS400 CardWith DB9 or 9 Pin Connector
AGENCY
ListingUL1778/cULUL1778/cULUL1778/cULUL1778/cULUL1778/cULUL1778/cULUL1778/CE/cUL UL1778/CE/cUL
* Derate capacity to 95% when the output voltage is adjusted to 115VAC. Derate capacity to 90% when the output voltage is adjusted to 110VAC.
Derate capacity to 80% when the output voltage is adjusted to 100VAC.
**Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Load level 0-25%, 26-50%, 51-75% and 76-100%, Low Battery and Battery Good, Programmable Management Outlets working, UPS On-Line,
UPS in Frequency Converter Mode, UPS On Bypass, Alarm Disabled Indicator and Battery Charger Working.
Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes), Fault Indicator, Battery Voltage, Overload,
and/or UPS Output is short circuited.
Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure, Battery Fault, Bypass Out of Range and
Bypass Frequency Unstable
3.39" x 17.24" x 16.44" (2U)
[86.2 x 438.0 x 417.5]
17.24" x 3.39" x 16.44" (2U)
[438.0 x 86.2 x 417.5]
Low Voltage 80 VAC/70 VAC/60 VAC/55 VAC ± 5 %
>0.99 @nominal voltage
8% max (Battery mode before shut down)
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
17.24" x 3.39" x 20.38" (2U)
[438.0 x 86.2 x 517.5]
< 2% (Linear load)
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
17.24" x 3.39" x 20.38" (2U)
[438.0 x 86.2 x 517.5]
3.39" x 17.24" x 27.74" (2U)
[86.2 x 438.0 x 704.6]
17.24" x 3.39" x 27.74" (2U)
[438.0 x 86.2 x 517.5]
Staco Energy Products Co.
Page 5
The Staco V Series Battery Run Time Charts
Standard External Battery Run Time Chart - Minutes Used with Staco V Series, 120 VAC, Standard Models, Universal Tower/Rack 1000VA, 1500VA, 2000VA & 3000VA
UPS
Rating
I000VAInternal01/026.911.76.64
I500VAInternal01/026.911.76.64
2000VAInternal01/026.911.76.64
3000VA Internal01/026.911.76.64
Note: 1. ONLY (1) Standard Battery Pack can be used on the SCV-X0002 Models without effecting recharge time.
If (2) battery packs are used the recharge will take twice the time.
2. If longer run times are needed or future expansion is planned the LB Model is recommended.
3. Run times included total of internal and external battery strings.
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Model
(Part Number)
V1000EBC
(SCV-BAT-1K)
V1500EBC
(SCV-BAT-1.5K)
V2000EBC
(SCV-BAT-2K)
V3000EBC
(SCV-BAT-3K)
Quantity
Cabinets
11/2103.34729.220.2
11/2103.34729.220.2
11/2103.34729.220.2
11/2103.34729.220.2
Standard External Battery Run Time Chart - Minutes Used with Staco V, 120VAC, XL Models, Universal Rack/Tower 900VA, 1250VA, 1700VA & 2500VA
UPS Rating
900VA Internal000000
1250VA Internal000000
1700VAInternal000000
2500VA Internal000000
Note: Weights include the total of all cabinets
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Model
(Part Number)
V1000EBC
(SCV-BAT-1K)
V1500EBC
(SCV-BAT-1.5K)
V2000EBC
(SCV-BAT-2K)
V3000EBC
(SCV-BAT-3K)
Quantity
Cabinets
1271.832.52013.7
24165.87647.433.176 / (34)
1278.835.72215.2
24181.883.452.136.4110 / (50)
1276.934.921.514.8
24177.581.550.835.5128 / (58)
1278.835.72215.2
24181.883.452.136.4182 / (82)
# Strings
Internal/External
# Strings25% Load50% Load75% Load
25% Load50% Load75% Load100% Load
100% Load
*Dimensions
H" x W" x D" / [mm]
3.39" x 17.24" x 17.04" (2U)
[86.2 x 438.0 x 432.7]
3.39" x 17.24" x 20.97" (2U)
[86.2 x 438.0 x 532.7]
3.39" x 17.24" x 20.97" (2U)
[86.2 x 438.0 x 532.7]
3.39" x 17.24" x 25.70" (2U)
[86.2 x 438.0 x 652.7]
*Dimensions
H" x W" x D" / [mm]
3.39" x 17.24" x 17.04" (2U)
[86.2 x 438.0 x 432.7]
3.39" x 17.24" x 20.97" (2U)
[86.2 x 438.0 x 532.7]
3.39" x 17.24" x 20.97" (2U)
[86.2 x 438.0 x 532.7]
3.39" x 17.24" x 25.70" (2U)
[86.2 x 438.0 x 652.7]
*Wt.
lbs. / (kg)
38 / (17)
55 / (25)
64 / (29)
91 / (41)
*Wt.
lbs. / (kg)
38 / (17)
55 / (25)
64 / (29)
91 / (41)
Staco V Rack/Tower
Page 6
The Staco V Series Battery Run Time Charts (Continued)
Extended Battery Run Time Chart - Minutes Used with Staco V, 120VAC, XL Models, Universal Rack/Tower 900VA, 1250VA, 1700VA & 2500VA
UPS RatingPart Number
(2) HR1290W Batteries per string
900VA
(2) HR12150W Batteries per string
900VA
(3) HR1290W Batteries per string
1250VA
(3) HR12150W Batteries per string
1250VA
(4) HR1290W Batteries per string
1700VA
(4) HR12150W Batteries per string
1700VA
(6) HR1251W Batteries per string
2500VA
(6) HR12150W Batteries per string
2500VA
Note: 1. Battery Times are based on new batteries +/- 5%.
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights