SB series
Line Interactive UPS
Inspection
The following items are inside the box:
● UPS unit ● User manual ● USB cable ● software CD
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is
discovered, re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6
hours prior to initial use.
SB-04001 SB-06001/ SB-08001
SB-10001 SB-15001/ SB-20001
A – Battery backup outlets
B – AC Input
C – Fuse/Circuit Breaker
D – USB com port
E – Cooling fan (1500/2000 models)
Plug in Equipment
Plug your equipment to Battery Backup Outlets on the rear panel
of the UPS.
NOTE: Make sure that the UPS is powered on to protect all
important devices from data loss during power failure.
REMARQUE: Assurez-vous que l’UPS est en marche pour
protéger tous les dispositifs importants de perte de données lors
de panne de courant.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup outlets of UPS. The equipment may draw
significant power to overload the UPS.
AVERTISSEMENT: Ne jamais raccorder une imprimante laser ou
un scanner pour les prises de sauvegarde batterie de l’onduleur.
L’équipement peut exiger beaucoup d’énergie de surcharger le
système UPS
Connect Com. Port and Install Software
Connect one end of the USB cable to PC and the other to the USB
port at the rear of the UPS.
Download the ViewPower software to your hard drive. Follow onscreen instructions to complete the software installation.
Operation Display
on, it will enter this mode
When AVR is
functioning, icon will
displayed in the following
order when LCD is
touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
alarm will beep every 0.5
second.
Mode
When battery level is
low, icon will flash.
seconds and LCD
information will be
displayed in the following
order when LCD is
touched.
1. Output voltage
2. Input voltage
3. Load level
alarm will beep every 0.5
second.
NOTE: If backlight shuts off, you may activate it by touching the
screen.
Remarque: Si le rétro-éclairage s’éteint, vous pouvez l’activer en
touchant l’écran.
![](/html/8f/8f28/8f284a45c01206613a8b54e1a61bb5dccb189f4d675d26fa3a262a2f7653e1b1/bg2.png)
Disconnect short-circuited
loads and restart the UPS
Disconnect all output l oads
and restart the UPS again.
Call for service immediately.
Bad or severely
discharged battery
Please replace the battery.
High output
voltage fault
Call for service immediately.
1. Turn off the unit and wait for
cooling.
2. Or remove excessive loads
Nothing is
displayed on
LCD panel.
not on. Pr ess the pow er sw itch
again to turn on the UPS.
Battery voltage is too
low.
Charge the battery at least
The UPS
always on
battery mode.
Re-plug the power cord.
The UPS
continuously
code for the details.
Please check the fault code
for the details.
Backup time
too short.
Battery voltage is too
low.
Charge the battery at least
loads. Before reconnecting
equipment, please verify
that the load matches the
UPS capability specification.
Output Voltage
Regulation
6 hours recover to 90% capacity
0-90% RH @ 0-40°C non-condensing)
Output Voltage
Regulation
6 hours recover to 90% capacity
0-90% RH @ 0-40°C non-condensing)