Stack ST747 User Information

ST747 0-10 Bar / 150 PSI
PRESSURE SENSOR (1/8 NPTF)
USER INFORMATION
(ST541047-004)
Stack Limited, Wedgwood Road, Bicester, Oxfordshire, OX26 4UL, England.
Tel.(01869) 240404 Fax (01869) 245500
INSTALLATION
Suggested Wiring Clearances Min space ST747 Ignition HT & coil leads 75mm (3”) Radio transmitters 50mm (2”) Fast switching inductive loads like
50mm (2”) fuel injectors, hydraulic solenoids. Any powerful source of heat Shield with reflective
material
Although it is possible to mount the sensors directly to the engine block, if the engine vibration is excessive, it is recommended that they are mounted indirectly, if possible, using flexible connections.
All STACK pressure sensors will withstand an over-pressure of only double their working maximum. Therefore, it is recommended that they be connected via an in-line pressure restrictor to eliminate the possibility of damage from any short high-pressure pulses, which may exist. If an adaptor is required to enable mounting of the transmitter it is possible to incorporate the restrictor into this part. The restriction should take the form of a 1mm diameter x 25mm long hole.
These terminals must be connected to the corresponding terminals of the selected input channel.
Pin Number Signal Description 1 Output from sensor
2 5v supply voltage
3 No connection 40v
ST747 TECHNICAL SPECIFICATION
Range 10 Bar Over-range 20 Bar Resolution 100 mB Accuracy 2% Accuracy/Temp 3% Output Voltage 0.5 – 4.5 volts Working Temp -30 to +120 Degrees Centigrade Storage Temp -40 to +140 Degrees Centigrade Vibration 15G (33.3 to 200 Hz) Pressure Port 1/8” NPTF Male
Sensor Connections
Sensors connect into Stack Systems via a four way, Mini Sure Seal (MSS) connector. The following polarity is observed in all cases:
= Pin
= Socket
Plug Harness End
12
34
Socket Sensor End
12
34
Sealing IP65
ST747 - User Manual (ST541047)