ST XL0840 User Manual

®
XL0840
SENSITIVE GATE 0.8A SCRs
MAIN FEATURES
Symbol Value Unit
I
T(RMS)
V
DRM
I
GT
0.8 A 400 V 200 µA
DESCRIPTION
Thanks to its highly sensitive triggering levels, the XL0840 device is suitable for all high volumes appli­cations where the available gate current is limited, such as Christmas lights control.
ABSOLUTE RATINGS (limiting values)
A
G
K
K
G
A
TO-92
Symbol Parameter Value Unit
I
T(RMS)
I
T(AV)
I
TSM
2
tI
I
dI/dt Critical rate of rise of on-state current
I
GM
P
G(AV)
T
stg
T
j
January 2002 - Ed: 1A
current
2
t Value for fusing tp = 10 ms Tj = 25°C 0.24 A2s
tp = 8.3 ms
Tj = 25°C
tp=10ms 7
8A
F = 60 Hz Tj = 125°C 30 A/µs
=2xIGT,tr100ns
I
G
Operating junction temperature range
-40to+150
-40to+125
°C
1/5
XL0840
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)
Symbol Test Conditions XL0840 Unit
I
GT
V
GT
V
GD
V
RG
I
H
I
L
dV/dt V
V
TM
V
TO
VD=12V RL=140 MAX. 200 µA
MAX. 0.8 V
VD=V
DRMRL
=3.3kRGK=1k Tj = 125°C MIN. 0.1 V IRG= 10µA MIN. 8 V IT= 50mA RGK=1k MAX. 5 mA
IG= 1mA RGK=1k MAX. 6 mA
=67% V
D
DRMRGK
=1k Tj= 125°C MIN. 75 V/µs ITM= 1.6A tp = 380µs Tj = 25°C MAX. 1.95 V Threshold voltage Tj = 125°C MAX. 1.0 V
Rd Dynamic resistance Tj = 125°C MAX. 600 m
I
DRM
V
DRMRGK
=1k Tj = 25°C MAX. 1 µA
Tj = 125°C 100
THERMAL RESISTANCES
Symbol Parameter Value Unit
Rth(j-a) Junction to ambient (DC) 150 °C/W
Rth(j-l) Junction to lead (DC) 80 °C/W
PRODUCT SELECTOR
Part Number Voltage Sensitivity Package
XL0840 400V 200 µA TO-92
ORDERING INFORMATION
X L 08 40
SENSITIVE SCR
LIGHT CONTROL
CURRENT:0.8A
OTHER INFORMATION
Part Number Marking Weight Base quantity Packing mode
VOLTAGE: 40: 400V
XL0840 XL0840 0.2 g 2500 Bulk
2/5
Loading...