The device is an off-line converter with an 800 V
rugged power section, a PWM control, two levels
of over current protection, over voltage and
overload protections, hysteretic thermal
protection, soft-start and safe auto-restart after
any fault condition removal. Burst mode operation
and device very low consumption helps to meet
the standby energy saving regulations.
Advance frequency jittering reduces EMI filter
cost. Brown-out function is embedded into the
high voltage start-up.
1. Typical continuous power in non ventilated enclosed adapter measured at 50 °C ambient.
2. Maximum practical continuous power in an open frame design at 50
°C ambient, with adequate heat sinking.
4/31
85-265 V
(1)
AC
Open frame
(2)
VIPER17Pin settings
3 Pin settings
3.1 Connection diagram
Figure 3.Connection diagram (top view)
3.2 Pin description
Table 3.Pin description
N.NameFunction
1GNDThis pin represents the device ground and the source of the power section.
2VDD
3CONT
4FB
Supply voltage of the control section. This pin also provides the charging
current of the external capacitor during start-up time.
Control pin. The following functions can be selected:
1. current limit set point adjustment. The internal set default value of the cycleby-cycle current limit can be reduced by connecting to ground an external
resistor.
2. output voltage monitoring. A voltage exceeding 3V shuts the IC down
reducing the device consumption. This function is strobed and digitally filtered
for high noise immunity.
Control input for duty cycle control. Internal current generator provides bias
current for loop regulation. A voltage below 0.5 V activates the burst-mode
operation. A level close to 3.3 V means that we are approaching the cycle-bycycle over-current set point.
GND
VDD
CONT
FB
DRAIN
DRAIN
BR
5BR
7,8DRAIN
Brownout protection input with hysteresis. A voltage below 0.45 V shuts down
(not latch) the device and lowers the power consumption. Device operation
restarts as the voltage exceeds 0.45 V plus hysteresis voltage. It can be
connected to ground when not used.
High voltage drain pin. The built-in high voltage switched start-up bias current is
drawn from this pin too.
5/31
Electrical dataVIPER17
4 Electrical data
4.1 Maximum ratings
Table 4.Absolute maximum ratings
SymbolPinParameterValueUnit
V
DRAIN
E
I
AR
I
DRAIN
V
CONT
V
V
V
P
TOT
T
T
STG
AV
FB
BR
DD
J
7, 8Drain-to-source (ground) voltage 800V
7, 8Repetitive avalanche energy (limited by TJ = 150 °C)2mJ
7, 8Repetitive avalanche current (limited by TJ = 150 °C )0.6A
7, 8Pulse drain current0.7A
3Control input pin voltage (with I
4Feedback voltage-0.3 to 5.5V
5Brown-out input pin voltage2V
2Supply voltage (IDD = 25 mA)Self limitedV
4.2 Thermal data
Table 5.Thermal data
SymbolParameterMax valueUnit
R
R
Thermal resistance junction pin40°C/W
thJP
Thermal resistance junction ambient
thJA
= 1 mA)Self limitedV
CONT
Power dissipation at TA < 50 °C1W
Operating junction temperature range-40 to 150°C
Storage temperature-55 to 150°C
90 °C/W
(1)
80
°C/W
1. When mounted on a standard single side FR4 board whit 200 mm2 (0.31 sq in) Of Cu (35 m thick)
6/31
VIPER17Electrical data
4.3 Electrical characteristics
(TJ = -25 to 125 °C, VDD = 14 V; unless otherwise specified)
Table 6.Power section
SymbolParameterTest conditionMinTypMaxUnit
I
= 1 mA, VFB = GND
V
BVDSS
I
OFF
R
DS(on)
C
OSS
Table 7.Supply section
Break-down voltage
OFF state drain current
Drain-source on state
resistance
Effective (energy related)
output capacitance
SymbolParameterTest conditionMinTypMaxUnit
DRAIN
TJ = 25 °C
V
V
I
= max rating,
DRAIN
= GND
FB
= 0.2 A, VFB = 3 V,
DRAIN
VBR = GND, TJ = 25 °C
I
= 0.2 A, VFB = 3 V ,
DRAIN
VBR = GND, TJ = 125 °C
V
= 0 to 640 V10pF
DRAIN
800V
60µA
2024Ω
4048Ω
Volt ag e
V
DRAIN
I
DD_CH
V
DD
V
DDclamp
V
DDon
V
DDoff
V
DD(RESTART)
Current
I
DD0
I
DD1
I
DD_FAULT
I
DD_OFF
_START
Drain-source start voltage6080100V
Start up charging current
V
VBR = GND, VFB = GND,
V
V
V
= 120 V,
DRAIN
= 4 V
DD
= 120 V ,
DRAIN
= GND, VFB = GND,
BR
-2-3-4mA
-0.4-0.6-0.8mA
VDD = 4 V after fault.
Operating voltage rangeAfter turn-on8.523.5V
VDD clamp voltageIDD = 20 mA23.5V
VDD start up threshold
VDD under voltage
shutdown threshold
VDD restart voltage
threshold
Operating supply current,
not switching
Operating supply current,
switching
Operating supply current,
with protection tripping
Operating supply current
with VDD < V
DD_OFF
V
V
V
= 120 V,
DRAIN
= GND, VFB = GND
BR
= 120 V,
DRAIN
VBR = GND, VFB = GND
VFB = GND, FSW = 0 k H z ,
VBR = GND, VDD = 10 V
V
DRAIN
= 120 V,
FSW = 60 kHz
V
DRAIN
= 120 V,
FSW = 115 kHz
VDD = 7 V 270uA
131415V
7.588.5V
44.55 V
0.9mA
1.8mA
2mA
400uA
7/31
Electrical dataVIPER17
Table 8.Controller section
(T
= -25 to 125 °C, V
J
SymbolParameterTest conditionMinTypMaxUnit
Feedback pin
= 14 V; unless otherwise specified)
DD
V
FB_olp
V
FB_lin
V
FB_bm
V
FB_bm_hys
Over load shut down
threshold
Linear dynamics upper limit3.23.33.4V
Burst mode thresholdVoltage falling0.5V
Burst mode hysteresisVoltage rising 50mV
4.74.85.2V
VFB = 0.3 V-150-200-280uA
I
R
FB(DYN)
H
FB
FB
Feedback sourced current
Dynamic resistanceV
∆VFB / ∆I
D
3.3 V < V
FB
< 4.8 V-3uA
FB
< 3.3 V1419kΩ
49V/A
CONT pin
VCONT_lLow level clamp voltageI
= -100 uA0.5V
CONT
Current limitation
VFB = 4 V,
I
Dlim
Max drain current limitation
I
CONT
= -10 µA
0.380.40.42A
TJ = 25 °C
t
SS
T
ON_MIN
Soft-start time8.5ms
Minimum turn ON time 400ns
tdPropagation delay 150ns
t
LEB
I
D_BM
Leading edge blanking 300ns
Peak drain current during
burst mode
Oscillator section
VIPER17LVDD = operating
F
OSC
VIPER17H103115127kHz
FDModulation depth
FMModulation frequency250Hz
D
MAX
Maximum duty cycle 7080%
8/31
V
= 0.6 V90mA
FB
546066kHz
voltage range,
VFB = 1 V
VIPER17L±4kHz
VIPER17H ±8kHz
VIPER17Electrical data
Table 8.Controller section (continued)
(T
= -25 to 125 °C, V
J
SymbolParameterTest conditionMinTypMaxUnit
= 14 V; unless otherwise specified)
DD
Over current protection ( 2
I
DMAX
Second over current
threshold
Over voltage protection
V
OVP
T
STROBE
Over voltage protection
threshold
Over voltage protection
strobe time
Brown out protection
V
BRth
V
BR Hyst
I
BR Hyst
V
V
BR
DIS
Brown out threshold
Voltage hysteresis above
V
BRth
Current hysteresis710uA
Operating range0.152V
Brown out disable voltage50150mV
Thermal shutdown
T
T
SD
HYST
Thermal shutdown
temperature
Thermal shutdown
hysteresis
nd
OCP )
0.6A
2.733.3V
2.2us
0.410.450.49V
50mV
Voltage falling
150170°C
30°C
9/31
Electrical dataVIPER17
Figure 4.Minimum turn-on time test circuit
Figure 5.Brown out threshold test circuits
Figure 6.OVP threshold test circuits
10/31
(The OVP protection is triggered after four consecutive oscillator cycles)