ST STTH5R06DJF User Manual

Features
Suited for DC/DC convertsLow lossesHigh T
■ ■ High energy avalanche capability1 mm package thicknessECOPACK
J
High surge current capability
®
2 compliant component
STTH5R06DJF
Ultrafast recovery diode high efficiency
Datasheet production data
A(1)
K
A(2)
K
K
Description
High performance diode suited for high frequency DC to DC converters. Packaged in PowerFLAT™ 5x6, this device is intended for use in low voltage high frequency inverters.
A(2)
A(1)
PowerFLAT 5x6
STTH5R06DJF

Table 1. Device summary

Symbol Value
I
F(AV)
V
RRM
T
j
V
(typ) 0.95 V
F
(typ) 30 ns
t
rr
A(2)
A(1)
5 A
600 V
175 °C
TM: PowerFLAT is a trademark of STMicroelectronics
March 2012 Doc ID 022760 Rev 1 1/9
This is information on a product in full production.
www.st.com
9
Characteristics STTH5R06DJF

1 Characteristics

Table 2. Absolute ratings (limiting values with anode terminals short-circuited)

Symbol Parameter Value Unit
V
I
F(RMS)
I
F(AV)
I
T

Table 3. Thermal parameter

Repetitive peak reverse voltage 600 V
RRM
Forward rms current 45 A
Average forward current
Surge non repetitive forward current
FSM
Storage temperature range -65 to + 175 °C
stg
Maximum operating junction temperature 175 °C
T
j
Tc = 160 °C δ = 0.5
= 10 ms
t
p
sinusoidal
5A
190 A
Symbol Parameter Maximum Unit
R

Table 4. Static electrical characteristics (anode terminals short-circuited)

Junction to case 2.0 °C/W
th(j-c)
Symbol Parameter Test conditions Min. Typ Max. Unit
(1)
I
V
1. Pulse test: tp = 5 ms, δ < 2%
2. Pulse test: tp = 380 µs, δ < 2%
Reverse leakage current
R
(2)
Forward voltage drop
F
T
= 25 °C
j
Tj = 125 °C 60 600
Tj = 25 °C
= 600V
V
R
1.55 2.00
IF = 5 A
= 125 °C 0.95 1.20
T
j
60
µA
V
To evaluate the maximum conduction losses use the following equation: P = 0.9 x I
2/9 Doc ID 022760 Rev 1
F(AV)
+ 0.06 I
F2(RMS)
STTH5R06DJF Characteristics
0

Table 5. Recovery characteristics

Symbol Parameter
Reverse recovery time Tj = 25 °C
t
rr
I
Reverse recovery current
RM
S

Table 6. Turn-on switching characteristics

Reverse recovery
factor
softness factor
Reverse recovery charges 180 nC
Q
rr
Tj = 125 °C
Symbol Parameter
Test conditions
= 1 A
I
F
Vr = 30 V
/dt = - 100 A/µs
dI
F
I
= 1 A
F
= 30 V
V
r
/dt = - 50 A/µs
dI
F
I
= 5 A,
F
/dt = - 200 A/µs,
dI
F
= 400 V
V
R
Test conditions
Min. Typ Max. Unit
30 40
ns
40 55
6.0 8.0 A
0.5 -
Min. Typ Max. Unit
t
Forward recovery time
fr
Tj = 25 °C
V
Forward recovery voltage 2.3 3.5 V
FP
IF = 5 A dIF/dt = - 100 A/µs V
Figure 1. Average forward power dissipation
versus average forward current
P
(W)
F(AV)
9
8
7
6
5
4
3
2
1
0
01234567
δ = 0.05
δ = 0.1
I
F(AV)
δ = 0.2
(A)
δ = 0.5
δ
δ = 1
=tp/T
T
tp
= 1.6 V
FR
Figure 2. Forward voltage drop versus
forward current
IFM(A)
100.0
10.0
1.0
0.1
Tj=125 °C
(Typical values)
Tj=125 °C
(Maximum values)
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.
Tj=25 °C
(Maximum values)
150 ns
VFM(V)
Doc ID 022760 Rev 1 3/9
Loading...
+ 6 hidden pages