A2
Symbol Value Unit
I
T(RMS)
V
DRM/VRRM
I
GT (Q1)
Available either in through-hole or surface-mount packages, the BTA/BTB12 and T1 2 triac series is suitable for general purpose AC sw itching. They can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor
12 A
600 and 800 V
5 to 50 mA
A1
G
A1
A2
A2
G
D2PAK
(T12-G)
A2
speed controllers,... The snubberless versions (BTA/BTB...W and T12 series) are specially recommended for use on inductive loads, than ks to their high com mutation performances. Logic level versions are designed to interface directly with low power drivers such as
A1
A2
G
A1
A2
G
microcontrollers. By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL
TO-220AB Insulated
(BTA12)
TO-220AB
(BTB12)
standards (File ref.: E81734)
ABSOLUTE MAXIMUM RATINGS
Symbol Parameter Value Unit
I
T(RMS)
I
TSM
²
I
dI/dt
V
DSM/VRSM
I
GM
P
G(AV)
T
stg
T
RMS on-state current (full sine wave)
Non repetitive surge peak on-state current (full cycle, Tj initial = 25°C)
tI
²
t Value for fusing
Critical rate of rise of on-state current I
= 2 x IGT , tr 100 ns
G
Non repetitive surge peak off-state voltage
Peak gate current tp = 20 µs Tj = 125°C 4 A Average gate power dissipation Tj = 125°C 1 W
Storage junction temperature range Operating junction temp erature range
j
September 2002 - Ed: 6A
²
PAK/TO-220AB
D
Tc = 105°C
12 A
TO-220AB Ins. Tc = 90°C
F = 50 Hz t = 20 ms 120 A F = 60 Hz t = 16.7 ms 126
tp = 10 ms 78
F = 120 Hz Tj = 125°C 50 A/µs
V
tp = 10 ms Tj = 25°C
DRM/VRRM
+ 100
- 40 to + 150
- 40 to + 125
A
V
°C
²
s
1/7
BTA/BTB12 and T12 Series
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)
SNUBBERLESS™ and LOGIC LEVEL (3 Quadrants)
Symbol Test Conditions Quadrant T12 BTA/BTB12
T1235 TW SW CW BW
I
GT
V
V
GT
GD
(1)
= 12 V RL = 30
V
D
VD = V
RL = 3.3 k
DRM
I - II - III MAX. 35 5 10 35 50 I - II - III MAX. 1.3 V
I - II - III MIN. 0.2
Tj = 125°C
I
(2)
H
I
L
= 100 mA
I
T
I
= 1.2 I
G
GT
MAX.3510153550mA
I - III MAX. 50 10 25 50 70 mA
II 60 15 30 60 80
dV/dt (2) V
= 67 %V
D
Tj = 125°C
gate open
DRM
MIN. 500 20 40 500 1000 V/µs
(dI/dt)c (2) (dV/dt)c = 0.1 V/µs Tj = 125°C MIN. - 3.5 6.5 - - A/ms
(dV/dt)c = 10 V/µs Tj = 125°C - 1 2.9 - ­Without snubber Tj = 125°C 6.5 - - 6.5 12
ST ANDARD (4 Quadrants)
Symbol Test Conditions Quadrant BTA/BTB12
CB
I
(1)
GT
V
GT
V
GD
I
(2)
H
I
L
= 12 V RL = 30
V
D
VD = V
= 500 mA
I
T
IG = 1.2 I
RL = 3.3 kTj = 125°C
DRM
GT
I - II - III
IV
MAX.
25 50
50
100 ALL MAX. 1.3 V ALL MIN.
0.2 V
MAX. 25 50 mA
I - III - IV MAX. 40 50 mA
II 80 100
dV/dt (2) V
= 67 %V
D
gate open Tj = 125°C
DRM
MIN. 200 400 V/µs
(dV/dt)c (2) (dI/dt)c = 5.3 A/ms Tj = 125°C MIN. 5 10 V/µs
Unit
mA
Unit
mA
V
STATIC CHARACTERISTICS
Symbol Test Conditions Value Unit
V
(2) ITM = 17 A tp = 380 µs
T
(2)
V
to
(2)
R
d
I
DRM
I
RRM
Note 1: minimum IGT is guaranted at 5% of IGT max. Note 2: for both polarities of A2 referenced to A1
Threshold voltage Tj = 125°C MAX. 0.85 V Dynamic resistance Tj = 125°C MAX. 35 m V
= V
DRM
RRM
2/7
Tj = 25°C MAX. 1.55 V
Tj = 25°C
Tj = 125°C 1 mA
MAX.
A
BTA/BTB12 and T12 Series
THERMAL RESISTANCES
Symbol Parameter Value Unit
R
th(j-c)
R
th(j-a)
S = Copper surface under tab
Junction to case (AC)
Junction to ambient
PRODUCT SELECTOR
S = 1 cm
²
²
PAK/TO-220AB
D
TO-220AB Insulated 2.3
D²PAK
TO-220AB
TO-220AB Insulated
1.4
45
60
°C/W
°C/W
Part Number
BTA/BTB12-xxxB X X 50 mA Standard TO-220AB BTA/BTB12-xxxBW X X 50 mA Snubberless TO-220AB BTA/BTB12-xxxC X X 25 mA Standard TO-220AB BTA/BTB12-xxxCW X X 35 mA Snubberless TO-220AB BTA/BTB12-xxxSW X X 10 mA Logic level TO-220AB BTA/BTB12-xxxTW X X 5 mA Logic Level TO-220AB T1235-xxxG X X 35 mA Snubberless
BTB: non insulated TO-220AB package
Voltage (xxx)
Sensitivity Type
600 V 800 V
Package
²
D
PAK
ORDERING INFORMA T IO N
BT A 12 - 600 BW (RG)
TRIAC SERIES
INSULATION: A: insulated B: non insulated
CURRENT:12A
VOLTAGE: 600: 600V 800: 800V
SENSITIVITY &TYPE B: 50mA STANDARD BW: 50mA SNUBBERLESS C: 25mA STANDARD CW: 35mA SNUBBERLESS SW: 10mA LOGIC LEVEL TW: 5mA LOGIC LEVEL
PACKING MODE Blank: Bulk RG:Tube
TRIAC SERIES
CURRENT:12A
T 12 35 - 600 G (-TR)
PACKAGE:
2
G: D PAK VOLTAGE: 600: 600V 800: 800V
SENSITIVITY: 35: 35mA
PACKING MODE: Blank:Tube
-TR:Tape & Reel
3/7