![](/html/4c/4cd3/4cd3b6bc9c1771191d77ffe7f23894520bb8c212d4bb522134f4b2bdceff1325/bg1.png)
High Load Currents up to
20 A, 200 A Inrush
Fixed or Adjustable Delays
From 0.1 s ... 1000 m
+/-0.5% Repeat Accuracy
+/-1% Factory Calibration
24, 120, or 230 V AC
Metallized Mounting Surface
for Efficient Heat Transfer
Totally Solid State and
Encapsulated
Delay On Break (Release)Delay On Break (Release)
Delay On Break (Release)
Delay On Break (Release)Delay On Break (Release)
THDB Digi-Power
Power Timing Module
DescriptionDescription
Description
DescriptionDescription
The THD Series combines accurate timing circuitry with high power solid state switching. It can switch motors,
lamps, and heaters directly without a contactor. You can reduce labor, component cost, and increase reliability
with these small, easy-to-use, Digi-Power timers.
OperationOperation
Operation
OperationOperation
Input voltage must be applied before and during
timing. Upon closure of the initiate switch, the output
energizes. The time delay begins when the initiate
switch is opened. The output remains energized
during timing. At the end of the time delay, the output
de-energizes. The output energizes if the initiate switch
is closed when input voltage is applied.
Reset:Reset:
Reset: Reclosing the initiate switch during timing
Reset:Reset:
resets the time delay . Loss of input voltage r esets the
time delay and output.
FunctionFunction
Function
FunctionFunction
Delay On Break
V = Voltage L = Load S1 = Initiate Switch
TD = Time Delay R = Reset
t = Incomplete Time Delay
= Undefined time
Approvals:
AccessoriesAccessories
Accessories
AccessoriesAccessories
BB
B
BB
External adjust
potentiometer
AA
A
AA
P/Ns:
P1004-95P1004-95
P1004-95
P1004-95P1004-95
P1004-95-XP1004-95-X
P1004-95-X
P1004-95-XP1004-95-X
Female quick connect
P/Ns:
P1015-64 P1015-64
P1015-64
P1015-64 P1015-64
P1015-13 P1015-13
P1015-13
P1015-13 P1015-13
Quick connect to
screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
Versa-knob
P0700-7 P0700-7
P/N:
P0700-7
P0700-7 P0700-7
(fig A)
See accessory pages for
specifications.
(fig B)
(AWG 14/16)
(AWG 10/12)
ConnectionConnection
Connection
ConnectionConnection
RT is used when external adjustment is ordered.
Dashed lines are internal connections.
UTL = Optional Untimed Load L = Timed Load S1 = Initiate Switch
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
THDBTHDB
THDB
THDBTHDB
SeriesSeries
Series
SeriesSeries
Example P/N: Example P/N:
Example P/N:
Example P/N: Example P/N:
ableable
able
ableable
X X
X
X X
InputInput
Input
InputInput
22
–
2 - 24 V AC
22
4 4
–
4 - 120 V AC
4 4
66
–
6
- 230 V AC
66
THDB420C THDB420C
THDB420C Fixed –
THDB420C THDB420C
XX
X
XX
AdjustmentAdjustment
Adjustment
AdjustmentAdjustment
11
–
1 - Fixed
11
2 2
–
2 - External
2 2
Adjust
3 3
–
3 - Onboard
3 3
Adjust
THDB410.1SATHDB410.1SA
THDB410.1SA
THDB410.1SATHDB410.1SA
XX
X
XX
Time DelayTime Delay
Time Delay *
Time DelayTime Delay
00
–
0 - 0.1 ... 10 s
00
11
–
1 - 1.0 ... 100 s
11
22
–
2 - 10 ... 1000 s
22
33
–
3 - 0.1 ... 10 m
33
44
–
4 - 1 ... 100 m
44
55
–
5 - 10 ... 1000 m
55
XX
X
XX
Output RatingOutput Rating
Output Rating
Output RatingOutput Rating
AA
–
A - 6 A
AA
BB
–
B - 10 A
BB
CC
–
C - 20 A
CC
*If Fixed Delay is selected, insert
0.10.1
delay [
((
SS
))
(
S
) secs. or
((
SS
))
10001000
0.1...
1000] followed by
0.10.1
10001000
((
MM
))
(
M
) mins.
((
MM
))
THDBGen 08.03.04
Low Voltage Products & Systems5.68
![](/html/4c/4cd3/4cd3b6bc9c1771191d77ffe7f23894520bb8c212d4bb522134f4b2bdceff1325/bg2.png)
Delay On Break (Release)Delay On Break (Release)
Delay On Break (Release)
Delay On Break (Release)Delay On Break (Release)
THDB Digi-Power
Power Timing Module
Technical DataTechnical Data
Technical Data
Technical DataTechnical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Range 0.1 s ... 1000 m in 6 adjustable ranges or fixed
Repeat Accuracy +/-0.5% or 20 ms, whichever is greater
Tolerance (Factory Calibration) ≤ +/-1%
Reset Time ≤ 150 ms
Initiate Time ≤ 20 ms
Time Delay vs. Temperature & Voltage ≤ +/-2%
InputInput
Input
InputInput
Voltage 24, 120, or 230 V AC
Tolerance +/-20%
Line Frequency 50 ... 60 Hz
Power Consumption ≤ 2 VA
OutputOutput
Output
OutputOutput
Type Solid state
Form Normally Open, closed before & during timing
Maximum Load Current Output Steady State Inrush**
Voltage Drop ≅ 2.5 V at rated current
Off State Leakage Current ≅ 5 mA at 230 V AC
Minimum Load Current 100 mA
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated
Dielectric Breakdown ≥ 2000 V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting ** Surface mount with one #10 (M5 x 0.8) screw
Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating/Storage Temperature -40°C ... +60°C / -40°C ... +85°C
Humidity 95% relative, non-condensing
Weight ≅ 3.9 oz (111 g)
A 6 A 60 A
B 10 A 100 A
C 20 A 200 A
** **
**Must be bolted to a metal surface using
** **
the included heat sink compound. The
maximum surface temperature is 90°C.
Inrush: Non-repetitive for 16 ms.
External Resistance vs Time DelayExternal Resistance vs Time Delay
External Resistance vs Time Delay
External Resistance vs Time DelayExternal Resistance vs Time Delay
THDBGen 08.03.04
Low Voltage Products & Systems 5.69
Mechanical ViewMechanical View
Mechanical View
Mechanical ViewMechanical View
Fixed & External AdjustFixed & External Adjust
Fixed & External Adjust
Fixed & External AdjustFixed & External Adjust
Onboard AdjustOnboard Adjust
Onboard Adjust
Onboard AdjustOnboard Adjust
Inches (Millimeters)