SSAC TDI Series, TDIH Series, TDIL Series Data Sheet

TDI / TDIH / TDIL SeriesTimer - Interval
Connection:
L1 N/L2
Relay contacts are isolated.
The TDI Series is an interval timer that combines accurate digital circuitry with isolated, 10A rated, DPDT relay contacts in an 8-pin plug-in package. The TDI Series features DIP switch selectable time delays ranging from 0.1 to 10,230 seconds in three ranges. The TDI Series is the product of choice for custom control panel and OEM designers.
Operation (Interval):
Upon application of input voltage, the time delay begins.
The output relay is energized during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed.
Reset: Removing input voltage resets the time delay and the output.
For more information see:
Appendix A, pages 156-164 for function descriptions
and diagrams.
Appendix B, page 165, Figure 8 for dimensional drawing.
Digi-Set Binary Switch Operation:
Features:
• Switch settable time delay
• Three time ranges from 0.1s - 10,230s
• ±0.1% repeat accuracy
• ±2% setting accuracy
• 10A, DPDT output contacts
• LED indication Approvals:
Auxiliary Products:
• Panel mount kit: P/N: BZ1
• Octal 8-pin socket: P/N: NDS-8
• Hold-down clips (sold in pairs): P/N: PSC8 (NDS-8)
• DIN rail: P/N: C103PM (Al)
Available Models:
TDI120AL TDI12D TDI230AL TDI24AL
If desired part number is not listed, please call us to see if it is technically possible to build.
TDI24DL TDIH24AL TDIL120AL TDIL24DL
Order Table:
TDI - 1 - 1023s in 1s increments TDIH - 10 - 10,230s in 10s increments TDIL - 0.1 - 102.3s in 0.1s increments
X Input Voltage
─12D - 12VDC ─24A - 24VAC ─24D - 24VDC/28VDC ─110D - 110VDC ─120A - 120VAC ─230A - 230VAC
Specications
Time Delay
Type ...................................Digital integrated circuitry
Range** ................................0.1 - 102.3s in 0.1s increments
Repeat Accuracy ........................±0.1% or 20ms, whichever is greater
Setting Accuracy ........................±2% or 50ms, whichever is greater
Reset Time ..............................≤ 50ms
Recycle Time ............................≤ 150ms
Time Delay vs Temp. & Voltage ............±2%
Indicator ...............................LED glows during timing; relay is energized
Input
Voltage .................................12, 24, or 110VDC; 24, 120, or 230VAC
Tolerance 12VDC & 24VDC/AC .....-15% - 20%
110 to 230VAC/DC ......-20% - 10%
AC Line Frequency ......................50/60 Hz
Power Consumption .....................≤ 3.25W
Output
Type ...................................Electromechanical relay
X
LED Indication*
─L
* Note: LED not available in 12VDC
Form ...................................DPDT
Rating .................................10A resistive @ 120/240VAC & 28VDC;
1/3 hp @ 120/240VAC
Life ....................................Mechanical - 1 x107; Electrical - 1 x 10
Protection
Polarity ................................DC units are reverse polarity protected
Isolation Voltage .........................≥ 1500V RMS input to output
Mechanical
Mounting ..............................Plug-in socket
Dimensions .............................3.2 x 2.4 x 1.8 in. (81.3 x 60.7 x 45.2 mm)
Termination .............................Octal 8-pin plug-in
Environmental
Operating / Storage Temperature ..........-20° to 65°C / -30° to 85°C
Weight .................................≅ 6 oz (170 g)
** For CE approved applications, power must be removed from the unit when a switch position is changed.