SSAC TA Series Catalog Page

Lockout TimerLockout Timer
Lockout Timer
Lockout TimerLockout Timer TA Series HVAC/R Timer
DescriptionDescription
Description
DescriptionDescription
The TA Series prevents rapid recycling of a compressor. A lockout delay is started when the thermostat opens, or input voltage is lost. Eliminates tripped circuit breakers or blown fuses caused by a locked rotor during short cycling. The TA will not allow the compressor to start when the line voltage is low. Chatter of the compressor relay is eliminated. Because of the fast initiate time, bounce of the thermostat will not be transmitted to the compressor relay coil. A 30 second delay provides anti-reversing protection for scroll compressors.
Lockout Delay--Prevents Rapid Recycling of a Compressor Low Voltage Brownout Protection Circuitry to Activate the Cooling Anticipator (24 V AC
Models)
Eliminates Nuisance Service Calls Due to Blown Fuse or Tripped Breakers
Approvals:
(24 V AC only)
AccessoriesAccessories
Accessories
AccessoriesAccessories
Female quick connect P/N: P1015-64 P1015-64
P1015-64
(AWG 14/16)
P1015-64 P1015-64
OperationOperation
Operation
OperationOperation
On initial closure of the S1, the compressor relay energizes immediately. When S1 opens or input voltage is interrupted, a lockout time delay is initiated. During this lockout time delay, the compressor relay cannot be energized. The low voltage (
brownout
protection prevents energization of the compressor when the line voltage is low.
Reset:Reset:
Reset:
The lockout time delay cannot be reset.
Reset:Reset:
ConnectionConnection
Connection
ConnectionConnection
FunctionFunction
Function
FunctionFunction
)
V = Voltage S1 = Initiate Switch or Thermostat L = Load (CR) E = Ready R = Reset TD = Time Delay
Quick connect to screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
Mounting bracket
P1023-6 P1023-6
P/N:
P1023-6
P1023-6 P1023-6
DIN rail P/Ns: 017322005 017322005
017322005 (Stee l)
017322005 017322005
C103PM C103PM
C103PM (Al)
C103PM C103PM
DIN rail adaptor
P1023-20 P1023-20
P/N:
P1023-20
P1023-20 P1023-20
See accessory pages for specifications.
Dashed lines are internal connections.
S1 = Initiate Switch, Contact, or Thermostat CR = Compressor Relay (Load) CA = Optional Cooling Anticipator
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
ableable
able
ableable
InputInput
Input
InputInput
24 V AC 24 V AC 24 V AC 24 V AC 12 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Time DelayTime Delay
Time Delay
Time DelayTime Delay
30 s 2 m 3 m 5 m 1 m 30 s 2 m 3 m 5 m
Part NumberPart Number
Part Number
Part NumberPart Number
TA24A0.5 TA24A2 TA24A3 TA24A5 TA12D1 TA24D0.5 TA24D2 TA24D3 TA24D5
Low Voltage Products & Systems5.226
TA002B01 01.05.05
Lockout TimerLockout Timer
Lockout Timer
Lockout TimerLockout Timer TA Series HVAC/R Timer
Technical Data Technical Data
Technical Data
Technical Data Technical Data
InputInput
Input
InputInput
Voltage/Frequency 12 or 24 V DC; 24 V AC, 50 ... 60 Hz Impedance 450 Ω (anticipator by-pass)
OutputOutput
Output
OutputOutput
Minimum Load Current 75 mA Maximum Load Current 1 A at 60°C Voltage Drop 1.25 V
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Initiate Time 16 ms Lockout Time Fixed 0.5, 1, 2, 3, or 5 m Tolerance -15% ... +35%
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated Low Voltage Protection 20 V: 24 V AC/DC; 9 V: 12 V DC Dielectric Breakdown 2000 V RMS terminals to mounting surface Insulation Resistance 100
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating Temperature -40°C ... +70°C Storage Temperature -40°C ... +85°C Humidity 95% relative, non-condensing Weight 2.4 oz (68 g)
ThermostatThermostat
Thermostat
ThermostatThermostat
Cooling Anticipator Resistor 1800
M
Mechanical View Mechanical View
Mechanical View
Mechanical View Mechanical View
Inches (Millimeters)
TA002B01 01.05.05
Low Voltage Products & Systems 5.227
Loading...