SSAC RS Digi-Set Catalog Page

Page 1
Recycling (Pulse Generator)Recycling (Pulse Generator)
Recycling (Pulse Generator)
Recycling (Pulse Generator)Recycling (Pulse Generator) RS Digi-Set Timing Module
DescriptionDescription
Description
DescriptionDescription
The RS Series is a solid state, encapsulated, recycling timer designed for tough industrial environments. It is used by many testing labs as a life cycle tester; by others as a cycle controller. The RS Series has separate DIP switch adjustments for the ON delay and the OFF delay. These make possible accurate adjustment the first time and every time. Time Delays of 0.1 seconds to 1023 hours are available in 4 ranges.
Accurate, Reliable Recycling
Timer Switch Settable Time Delays -
Both Times Adjustable
+/-0.1% Repeat Accuracy +/-2% Setting Accuracy
0.1 s ... 1023 h in 4 Ranges 12 ... 230 V in 5 ranges 1 A Solid State Output Totally Solid State and
Encapsulated Approvals:
AccessoriesAccessories
Accessories
AccessoriesAccessories
Mounting bracket
P1023-6 P1023-6
P/N:
P1023-6
P1023-6 P1023-6
Operation (ON Time First)Operation (ON Time First)
Operation (ON Time First)
Operation (ON Time First)Operation (ON Time First)
Upon application of input voltage, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the T2 OFF time begins. At the end of the OFF time, the output energizes and the cycle repeats as long as input voltage is applied.
Reset: Reset:
Reset: Removing input voltage resets the output
Reset: Reset:
and time delays, and returns the sequence to the ON time.
Operation (OFF Time First)Operation (OFF Time First)
Operation (OFF Time First)
Operation (OFF Time First)Operation (OFF Time First)
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the cycle repeats as long as input voltage is applied.
Reset: Reset:
Reset: Removing input voltage resets the output and
Reset: Reset:
time delays, and returns the sequence to the OFF time.
ConnectionConnection
Connection
ConnectionConnection
FunctionFunction
Function
FunctionFunction
Recycling (ON First)
Recycling (OFF First)
V = Voltage L = Load R = Reset
T1 = ON Time T2 = OFF Time
Female quick connect
::
P/N
:
::
P1015-64P1015-64
P1015-64
(AWG 14/16)
P1015-64P1015-64
Quick connect to screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
DIN rail P/Ns: 017322005 017322005
017322005 (Steel)
017322005 017322005 C103PM C103PM
C103PM (Al)
C103PM C103PM
DIN rail adaptor
P1023-20 P1023-20
P/N:
P1023-20
P1023-20 P1023-20
See accessory pages for specifications.
T1T1
T1
T1T1
T2T2
T2
T2T2
Dashed lines are internal connections.
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
RSRS
RS
RSRS
SeriesSeries
Series
SeriesSeries
Example P/N: Example P/N:
Example P/N:
Example P/N: Example P/N:
ableable
able
ableable
XX
X
XX
InputInput
InputInput
Input
Input
InputInput
InputInput
1 1
- -
1
- 12 V DC
1 1
- -
2 2
- -
2
- 24 V AC –
2 2
- -
3 3
- -
3
- 24 V DC
3 3
- -
4 4
4 - 120 V AC 0.1 m increments
4 4 6 6
6 - 230 V AC
6 6
RS4A23, RS6B14RS4A23, RS6B14
RS4A23, RS6B14
RS4A23, RS6B14RS4A23, RS6B14
XX
X
XX
Operating SequenceOperating Sequence
Operating Sequence T1 ON TimeT1 ON Time
Operating SequenceOperating Sequence
AA
A - ON Time First
AA BB
B - OFF Time First 0.1 s increments
BB
X X
X
X X
T1 ON TimeT1 ON Time
T1 ON Time
11
1 - 0.1 ... 102.3 s in
11 22
2 - 0.1 ... 102.3 m in
22
3 3
- -
3
- 1 ... 1023 m in
3 3
- -
1 m increments
44
4 - 1 ... 1023 h in
44
1 h increments
X X
X
X X
T2 OFF TimeT2 OFF Time
T2 OFF Time
T2 OFF TimeT2 OFF Time
11
- -
1
-
11
- -
0.1 ... 102.3 s in
0.1 s increments
22
- -
2
-
22
- -
0.1 ... 102.3 m in
0.1 m increments
33
- -
3
-
33
- -
1 ... 1023 m in 1 m increments
4 4
--
4
-
4 4
--
1 ... 1023 h in 1 h increments
Low Voltage Products & Systems5.178
RSGen 11.11.04
Page 2
Recycling (Pulse Generator)Recycling (Pulse Generator)
Recycling (Pulse Generator)
Recycling (Pulse Generator)Recycling (Pulse Generator) RS Digi-Set Timing Module
Technical Data Technical Data
Technical Data
Technical Data Technical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Range* 0.1 ... 102.3 s in 0.1 s increments
Repeat Accuracy +/-0.1% or 20 ms, whichever is greater Setting Accuracy < +/-2% or 20 ms, whichever is greater Reset Time Time Delay vs Temperature & Voltage < +/- 2%
InputInput
Input
InputInput
Voltage 12, or 24 V DC; 24, 120, or 230 V AC Tolerance +/-20% Line Frequency 50 ... 60 Hz DC Ripple < +/-10% Power Consumption AC < 2 VA; DC < 1 W
OutputOutput
Output
OutputOutput
Type Solid state Maximum Load Current 1 A steady state, 10 A inrush at 60°C OFF State Leakage Current AC 5 mA at 230 VAC; DC 1 mA Voltage Drop AC 2.5 V at 1 A; DC ≅ 1 V at 1 A
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated Dielectric Breakdown 2000 V RMS terminals to mounting surface Insulation Resistance 100 M Polarity DC units are reverse polarity protected
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw Package 3 x 2 x 1.5 in (76.7 x 51.3 x 38.1 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating Temperature -40°C ... +75°C Storage Temperature -40°C ... +85°C Humidity 95% relative, non-condensing Weight 3.9 oz (111 g)
0.1 ... 102.3 m in 0.1 m increments 1 ... 1023 m in 1 m increments 1 ... 1023 h in 1 h increments
< 150 ms
*For CE approved applications, power must be removed from the unit when a switch position is changed.
Mechanical View Mechanical View
Mechanical View
Mechanical View Mechanical View
Add the value of switches in the ON
RSGen 11.11.04
Low Voltage Products & Systems 5.179
position for the total time delay.