SSAC TDU Digi-Set, KSDU Digi-Set Catalog Page

Page 1
Delay On Make (Operate)
TDU, KSDU Digi-Set Timing Modules
Description
The TDU and KSDU Series are encapsulated solid state delay on make timers that combine digital timing circuitry with universal voltage operation. The TDU offers DIP switch adjustment allowing accurate selection of the time delay over the full time delay range. The KSDU is factory fixed from 0.1 s to 10,230 s and does not include the DIP switch. These series are excellent choices for process control systems and OEM equipment.
2 Universal Voltage Ranges From 24 ... 240 V AC/DC Digital Integrated Circuitry Switch Selectable Delays From 0.1 s ... 2.8 h in 3
Ranges or Factory Fixed
+/-0.5% Repeat Accuracy 1 A Steady - 10 A Inrush Totally Solid State and Encapsulated
Approvals:
Accessories
Female quick connect P/N:
P1015-64
(AWG 14/16)
Operation
Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed. Reset: Removing input voltage resets the time delay and output.
Connection
Function
Delay On Make
V = Voltage R = Reset TD = Time Delay L = Load
= Undefined time
Quick connect to screw adaptor P/N: P1015-18
Mounting bracket P/N: P1023-6
DIN rail P/Ns:
017322005 (Steel)
C103PM (Al)
DIN rail adaptor P/N: P1023-20
See accessory pages for specifications.
Dashed lines are internal connections. Load may be connected to terminal 3 or 1. TDU has DIP switch adjustment; KSDU is fixed.
Ordering Table
TDU
Series
KSDU
Series
Example P/N:
Input Voltage Range
24 ... 120 AC/DC 100 ... 240 AC/DC 24 ... 120 AC/DC 100 ... 240 AC/DC 24 ... 120 AC/DC 100 ... 240 AC/DC
X
Input Voltage Range
8 - 24 ... 120 V AC/DC –9 - 100 ... 240 V AC/DC
KSDU81300, KSDU910.1
Time Range - Seconds
0.1 ... 102.3
0.1 ... 102.3 1 ... 1023 1 ... 1023 10 ... 10230 10 ... 10230
X
Type
1 - Fixed
X
Time Delay (Seconds)
–Specify fixed delay in seconds 0.1 ... 10230
Part Number
TDUL3000A TDUL3001A TDU3000A TDU3001A TDUH3000A TDUH3001A
TDKSDUB1 06.09.04
Low Voltage Products & Systems5.16
Page 2
Technical Data
Delay On Make (Operate)
TDU, KSDU Digi-Set Timing Modules
Time Delay
Type Digital integrated circuitry Range* Adjustable (TDU) 0.1 ... 102.3 s in 0.1 s increments
1 ... 1023 s in 1 s increments 10 ... 10230 s in 10 s increments
Fixed (KSDU) Fixed from 0.1 s ...10,230 s Repeat Accuracy +/-0.5% or 20 ms, whichever is greater Tolerance (Factory Calibration) +/-10% Recycle Time 150 ms Time Delay vs. Temperature & Voltage +/-5%
Input
Voltage 24 ... 120 V AC/DC
100 ... 240 V AC/DC Line Frequency 50 ... 60 Hz Tolerance +/-20%
Output
Type Solid state Form Normally Open, open during timing Maximum Load Current 1 A steady state, 10 A inrush at 60°C Minimum Holding Current 40 mA Voltage Drop 2.5 V at 1 A
Protection
Circuitry Encapsulated Dielectric Breakdown 2000 V RMS terminals to mounting surface Insulation Resistance 100 M
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating Temperature -40°C ... +60°C Storage Temperature -40°C ... +85°C Humidity 95% relative, non-condensing Weight 2.4 oz (68 g)
* For CE approved applications, power must be removed from the unit when a switch position is changed.
Mechanical View
TDU Adjustment
Digi-Set Binary Switch Operation
Inches (Millimeters)
TDKSDUB1 06.09.04
Low Voltage Products & Systems 5.17
Adjustment Switches Shown Not Included on KSDU Series.