The KSDR Series offers independent time adjustment of both delay periods. The KSDR is recommended for air
drying, automatic oiling, life testing, chemical metering, and automatic duty cycling. This series is designed for
general purpose commercial and industrial applications where a small, cost effective, reliable solid state timer
is required. The factory calibration for fixed time delays is within +/- 5% of the target delay. The repeat
accuracy, under stable conditions, is 0.5% of the selected time delay. This series is designed for input voltages
of 24, 120 or 230 volts AC. Time delays of 0.1 seconds to 1000 minutes are available in 6 ranges. The output is
rated 1 A steady and 10 A inrush. The modules are totally solid state and encapsulated to protect the electronic
circuitry.
Adjustable 0.1 s...1000 m
in 6 Ranges
+/-0.5% Repeat Accuracy
+/- 5% Factory Calibration
24, 120, or 230 V AC
1 A Solid State Output
Encapsulated
Approvals:
AccessoriesAccessories
Accessories
AccessoriesAccessories
BB
B
BB
External adjust
potentiometer
P/Ns:
AA
A
AA
P1004-95P1004-95
P1004-95
P1004-95P1004-95
P1004P1004
P1004
P1004P1004
Mounting bracket
P1023-6 P1023-6
P/N:
P1023-6
P1023-6 P1023-6
Female quick
connect
::
P/Ns
:
::
P1015-64P1015-64
P1015-64
P1015-64P1015-64
P1015-13 P1015-13
P1015-13
P1015-13 P1015-13
P1015-14P1015-14
P1015-14
P1015-14P1015-14
--
95-X 95-X
-
95-X (fig B)
--
95-X 95-X
(AWG 14/16)
(fig A)
((
(AWG 10/12)
((
(AWG 18/22)
Operation (ON Time First)Operation (ON Time First)
Operation (ON Time First)
Operation (ON Time First)Operation (ON Time First)
Upon application of input voltage, the output energizes
and the T1, ON time begins. At the end of the ON time,
the output de-energizes and the T2, OFF time begins.
At the end of the OFF time, the output energizes and
the cycle repeats as long as input voltage is applied.
Reset:Reset:
Reset: Removing input voltage resets the output
Reset:Reset:
and time delays, and returns the sequence to T1, ON
time.
Operation (OFF Time First)Operation (OFF Time First)
Operation (OFF Time First)
Operation (OFF Time First)Operation (OFF Time First)
Upon application of input voltage, the T2, OFF time
begins. At the end of the OFF time, the T1, ON time
begins and the load energizes. At the end of T1, T2
begins and the load de-energizes. This cycle repeats
until input voltage is removed.
Reset: Reset:
Reset: Rem oving input voltage resets the output and
Reset: Reset:
the sequence to T2, OFF time.
ConnectionConnection
Connection
ConnectionConnection
FunctionFunction
Function
FunctionFunction
V = Voltage R = Reset L = Load
T1 = ON Time T2 = OFF Time
Recycling (ON First)
Recycling (OFF First)
Quick connect to
screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
Versa-knob
P0700-7 P0700-7
P/N:
P0700-7
P0700-7 P0700-7
DIN rail P/Ns:
C103PM C103PM
C103PM (Al )
C103PM C103PM
017322005 017322005
017322005 (Stee l)
017322005 017322005
→
DIN rail adaptor
P1023-20 P1023-20
P/N:
P1023-20
P1023-20 P1023-20
See accessory pages for
specifications.
←
R
T is used when external adjustment is ordered.
Dashed lines are internal connections.
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
KSDRKSDR
KSDR
KSDRKSDR
SeriesSeries
Series
SeriesSeries
Example P/N: Example P/N:
Example P/N:
Example P/N: Example P/N:
ableable
able
ableable
XX
X
XX
InputInput
Input
InputInput
2 2
–
2 - 24 V AC
2 2
4 4
–
4 - 120 V AC
4 4
6 6
–
6 - 230 V AC
6 6
KSDR40A1 KSDR40A1
KSDR40A1
KSDR40A1 KSDR40A1
X X
X
X X
T1, ON TimeT1, ON Time
T1, ON Time
T1, ON TimeT1, ON Time
0 0
–
0 - 0.1 ... 10 s
0 0
11
–
1 - 1 ... 100 s
11
22
–
2 - 10 ... 1000 s
22
33
–
3 - 0.1 ... 10 m
33
44
–
4 - 1 ... 100 m
44
55
–
5 - 10 ... 1000 m
55
XX
X
XX
Operating SequenceOperating Sequence
Operating Sequence
Operating SequenceOperating Sequence
AA
–
A - ON Time First
AA
BB
–
B - OFF Time First
BB
XX
X
XX
T2, OFF TimeT2, OFF Time
T2, OFF Time
T2, OFF TimeT2, OFF Time
0 0
–
0 - 0.1 ... 10 s
0 0
11
–
1 - 1 ... 100 s
11
22
–
2 - 10 ... 1000 s
22
33
–
3 - 0.1 ... 10 m
33
44
–
4 - 1 ... 100 m
44
55
–
5 - 10 ... 1000 m
55
Low Voltage Products & Systems5.184
KSDRGen 10.12 . 0 4

Recycling (Pulse Generator)Recycling (Pulse Generator)
Recycling (Pulse Generator)
Recycling (Pulse Generator)Recycling (Pulse Generator)
KSDR Digi-Timer
Timing Module
Technical DataTechnical Data
Technical Data
Technical DataTechnical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Range 0.1 s ... 1000 m in 6 ranges
Repeat Accuracy +/-0.5% or 20 ms, whichever is greater
Tolerance (Factory Calibration) ≤ +/-5%
Reset Time ≤ 150 ms
Time Delay vs. Temperature & Voltage ≤ +/-10%
InputInput
Input
InputInput
Voltage 24, 120, or 230 V AC
Tolerance +/-20%
Line Frequency 50 ... 60 Hz
Power Consumption ≤ 2 VA
OutputOutput
Output
OutputOutput
Type Solid state
Rating 1 A steady state, 10 A inrush at 60°C
Voltage Drop ≅ 2.5 V at 1 A
OFF State Leakage Current ≅ 5 mA at 230 V AC
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated
Dielectric Breakdown ≥ 2000 V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination 0.25 in. (6.35 mm) male quick connect terminals
EnvironmentalEnvironmental
Environmental
EnvironmentalEnvironmental
Operating Temperature -40°C ... +75°C
Storage Temperature -40°C ... +85°C
Humidity 95% relative, non-condensing
Weight ≅ 2.4 oz (68 g)
External Resistance vs Time DelayExternal Resistance vs Time Delay
External Resistance vs Time Delay
External Resistance vs Time DelayExternal Resistance vs Time Delay
KSDRGen 10.12 . 0 4
Mechanical ViewMechanical View
Mechanical View
Mechanical ViewMechanical View
Inches (Millimeters)
Low Voltage Products & Systems 5.185