![](/html/34/34f0/34f0bf8d3ccb55dcf15a59887ccbc131dcba0b6cda29bb22b9c133c378cd6407/bg1.png)
Dedicated
timers
Recycling (Pulse Generator)
KRDR Digi-Timer
Time Delay Relay
Description
The KRDR Series is a compact time delay relay measuring only 2 in. (50.8 mm) square. Its solid state timing
circuit provides excellent repeat accuracy and stability. Encapsulation protects against shock, vibration, and
humidity. The KRDR Series is a cost effective recycling timer for OEM applications that require small size,
isolation, reliability, and long life.
Compact Time Delay Relay
Full 10 A SPDT Output
Contacts
Onboard Adjustment or Fixed
Time Delay
Delays from 100 ms...1000 m
in 6 Ranges
Input Voltages from 120...230V
in 6 Ranges
+/-0.5% Repeat Accuracy
+/-5% Factory Calibration
Approvals:
Operation (ON Time First)
Upon application of input voltage, the output relay
energizes and the T2 ON time begins. At the end of
the ON time, the output de-energizes and the T1 OFF
time begins. At the end of the OFF time, the output
relay energizes and the cycle repeats as long as input
voltage is applied.
Reset: Removing input voltage resets the output and
the time delays, and returns the sequence to the ON
time.
Operation (OFF Time First)
Upon application of input voltage, the T1 OFF time
begins. At the end of the OFF time, the T2 ON time
begins and the load energizes. At the end of the ON
time the load de-energizes, and the cycle repeats until
input voltage is removed.
Reset: Removing input voltage resets the output and
the sequence to the OFF time.
Connection
Function
Recycling (ON First)
Recycling (OFF First)
V = Voltage R = Reset
T1 = OFF Time T2 = ON Time
NO = Normally Open NC = Normally Closed
T1 = OFF Time T2 = ON Time
A knob is supplied for adjustable units. Dashed
lines are internal connections.
Ordering Table
KRDR
Series
Example P/N:
5.134 Low Voltage Products & Systems
1TRC 001 009 C0202 ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
X
Input
–1 - 12 V DC
–2 - 24 V AC
–3 - 24 V DC
–4 - 120 V AC
–5 - 110 V DC
–6 - 230 V AC
KRDR421A1 = 120 V AC, ON Time and OFF Time Onboard Adjustable, with ON Time from 1 to 100 seconds, ON
Time First Operation, with OFF Time from 1 to 100 seconds
Fixed- KRDR631B0.5S = 230 V AC, ON Time Onboard Adjustable from 1 to 100 seconds, OFF Time First Operation,
with OFF Time
X
Adjustments
–1 - Both Times Fixed
–2 - Both Times Adj.
–3 - ON Time Adj.
OFF Time Fixed
–4 - ON Time Fixed,
OFF Time Adj.
* If Fixed Delay is selected, insert delay [0.1 … 999] followed by (S) sec. or (M) min.
X X X
T2, ON Time *
–0 - 0.1 ... 10 s
–1 - 1 ... 100 s
–2 - 10 ... 1000 s
–3 - 0.1 ... 10 m
–4 - 1 ... 100 m
–5 - 10 ...1000 m
Operating Sequence
–A - ON Time First
–B - OFF Time First
T1, OFF Time *
–0 - 0.1 ... 10 s
–1 - 1 ... 100 s
–2 - 10 ... 1000 s
–3 - 0.1 ... 10 m
–4 - 1 ... 100 m
–5 - 10 ...1000 m
KRDRGen 08.15.06
![](/html/34/34f0/34f0bf8d3ccb55dcf15a59887ccbc131dcba0b6cda29bb22b9c133c378cd6407/bg2.png)
Recycling (Pulse Generator)
KRDR Digi-Timer
Time Delay Relay
Technical Data
Time Delay
Range 0.1 s ... 1000 m in 6 adjustable ranges or fixed
Repeat Accuracy +/-0.5 % or 20 ms, whichever is greater
Tolerance (Factory Calibration) ≤ +/-5%
Reset Time ≤ 150 ms
Time Delay vs. Temperature & Voltage ≤ +/-5%
Input
Voltage 12, 24 or 110 V DC; 24, 120 or 230 V AC
Tolerance 12 V DC & 24 V DC/AC -15% ... +20%
110 V DC & 120 or 230 V AC -20% ... +10%
AC Line Frequency/DC Ripple 50 ... 60 Hz / ≤ 10%
Power Consumption AC ≤ 2 VA; DC ≤ 2 W
Output
Type Isolated relay contacts
Form Single pole double throw (SPDT)
Rating (at 40°C) 10 A resistive at 125 V AC
5 A resistive at 230 V AC & 28 V DC; 1/4 hp at 125 V AC
Max. Switching Voltage 250 V AC
Life (Operations) Mechanical -- 1 x 107; Electrical -- 1 x 10
Protection
Circuitry Encapsulated
Isolation Voltage ≥ 1500 V RMS input to output
Insulation Resistance ≥ 100 MΩ
Polarity DC units are reverse polarity protected
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating/Storage Temperature -20°C ... +60°C/-40°C ... +85°C
Humidity 95% relative, non-condensing
Weight ≅ 2.6 oz (74 g)
5
Dedicated
timers
Output Current/Ambient Temp.
Accessories
Mounting bracket
P/N: P1023-6
Quick connect to
screw adaptor
P/N: P1015-18
→
DIN rail adaptor
P/N: P1023-20
Female quick connect
P/Ns:
P1015-64
(AWG 14/16)
P1015-13 (AWG 10/12)
DIN rail P/Ns:
017322005 (Steel)
C103PM (Al)
←
Mechanical View
Inches (Millimeters)
T1 = OFF time T2 = ON time
A knob is supplied for adjustable
time delays
See accessory pages for specifications.
KRDRGen 08.15.06
Low Voltage Products & Systems 5.135
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com 1TRC 001 009 C0202