SSAC HRPD Power-Time, HRID Power-Time Data Sheet

®
ProgramaCube
US Patent 6708135
Special Time Ranges and
Functions Available
Factory Programmed
30 A SPDT N.O. Output Con-
tacts
12 ... 240 V Operation in
2 Ranges
Delays from 100 ms ...
1000 h in 9 Ranges
+/-0.5% Repeat Accuracy
Approvals:
Accessories
B
External adjust potentiometer
A
P/Ns: P1004-95 ( g A) P1004-95-X (g B)
Versa-knob P/N: P0700-7
Quick connect to screw adaptor P/N: P1015-18
Female quick connect P/Ns:
P1015-64 P1015-13 (AWG 10/12)
Mounting bracket P/N: P1023-6
DIN rail P/Ns: C103PM (Al)
(AWG 14/16)
HRPD/HRID Power-Time
Time Delay Relay
Description
The HRPD/HRID Series combines an electromechanical relay with microcontroller timing circuitry. It is a factory programmed module available in any 1 of 12 standard functions. Modules are manufactured without the function assigned. When an order is received, the function software is added. It offers 12 to 240 V operation in two universal ranges and factory xed, onboard knob or externally adjustable time delays with a repeat accuracy of +/-0.5%. The high switching capacity of the output contacts allow for direct control of heavy loads like compressors, pumps, motors, heaters, and lighting. HRPD has non-isolated SPDT relay contacts, and the HRID has isolated SPDT relay contacts. An excellent choice for OEM applications where cost is a factor. Both offer dual functions in one convenient package.
Connection
HRPD HRID
Relay contacts are non-isolated.
S1 = Initiate Switch UTL = Optional Untimed Load NO = Normally Open NC = Normally Closed C = Common
External Resistance vs Time Delay
For details on external RT see the external resistance vs. time delay chart at the beginning of this section.
Mechanical View
Onboard Adjust Detail Replaces Terminals if Ordered
Inches (Millimeters)
**Function Chart Code
Delay On Make/Delay on Break MB Delay On Make/Recycle (ON Time First, Equal Times) MRE Delay On Make/Interval MI Delay On Make/Single Shot MS Interval/Recycle (ON Time First, Equal Times) IRE Delay On Break/Recycle (ON Time First, Equal Times) BRE Single Shot/Recycle (ON Time First, Equal Times) SRE Recycle (Both Times Adjustable, ON Time First) RXE Recycle (Both Times Adjustable, OFF Time First) RXD Interval/Delay On Make IM Accumulative Delay On Make/Interval AMI Single Shot Lockout SL
For a Complete List of Functions with Descriptions, see Timer Function Section.
Relay contacts are isolated.
RT is used when external adjustment is ordered. Dashed lines are internal connections.
DIN rail adaptor P/N: P1023-20
See accessory pages for specications.
Series
X
Input
W - 24...240 V AC
.........24...110 V DC
D - 12 ... 48 V DC
Example P/N:
HRPDW2221MB Fixed – HRIDD10.5S21RXE
Available Models-
HRIDD3434RXE HRIDD3434RXE HRIDW2122MB
Don’t see what you need? Call us for a minimum quantity and price quote!
X X X X X
First Adjustment (T1 or RT1)
1 - Fixed –2 - Onboard Adjust –3 - External Adjust
First Time Delay*
1 - 0.1 ... 10 s –2 - 1 ... 100 s –3 - 10 ... 1000 s –4 - 0.1 ... 10 m –5 - 1 ... 100 m –6 - 10 ... 1000 m –7 - 0.1 ... 10 h –8 - 1 ... 100 h –9 - 10 ... 1000 h
Second Adjustment (T2 or RT 2)
1 - Fixed –2 - Onboard Adjust –3 - External Adjust
Second Time Delay*
1 - 0.1 ... 10 s –2 - 1 ... 100 s –3 - 10 ... 1000 s –4 - 0.1 ... 10 m –5 - 1 ... 100 m –6 - 10 ... 1000 m –7 - 0.1 ... 10 h –8 - 1 ... 100 h –9 - 10 ... 1000 h
*If Fixed Delay is selected, insert delay [0.1 ... 999] followed by (S) secs., (M) mins., or (H) hrs.
Function**
–Specify Function (Refer to Function
Chart for Code)
HRPDGen 09.10
HRPD/HRID Power-Time
Time Delay Relay
Technical Data
Time Delay
Range 100 ms ... 1000 h in 9 adjustable ranges or xed Repeat Accuracy +/-0.5% or 20 ms, whichever is greater Tolerance (Factory Calibration) +/-2% Reset Time ≤ 150 ms Initiate Time ≤ 20 ms, ≤ 1500 operations per minute Time Delay vs. Temp. & Voltage ≤ +/-2%
Input
Voltage 12 ... 48 V DC; 24 ... 240 V AC / 24 ... 110 V DC Tolerance 12 ... 48 V DC -15% ... +20% 24 ... 110 V DC/24 ... 240 V AC -20% ... +10% Line Frequency 50 ... 60 Hz Power Consumption AC ≤ 4 VA; DC ≤ 2 W
Output
Type/Form Electromechanical relay/SPDT Ratings: General Purpose 125/240 V AC 30 A 15 A Resistive 125/240 V AC 30 A 15 A 28 V DC 20 A 10 A Motor Load 125 V AC 1 hp* 1/4 hp** 240 V AC 2 hp** 1 hp** Life Mechanical -- 1 x 10 Electrical -- 1 x 105, *3 x104, **6,000
Function Diagrams
MB
Delay On Make Delay On Break
SPDT-N.O SPDT-N.C.
6
For a Complete List of Functions with Descriptions, see Timer Function Section.
IRE
Interval Recycle
ProgramaCube
®
Protection
Surge IEEE C62.41-1991 Level A Circuitry Encapsulated Isolation Voltage Insulation Resistance ≥100 MΩ Polarity DC units are reverse polarity protected
Mechanical
Mounting Package 3 x 2 x 1.5 in. (76.7 x 51.3 x 38.1 mm) Termination
Environmental
Operating Temp. -40°C ... +60°C Storage Temp. -40°C ... +85°C Humidity 95% relative, non-condensing Weight 3.9 oz (111 g)
1500 V RMS input to output; isolated units
Surface mt. with one #10 (M5 x 0.8) screw
0.25 in. (6.35 mm) male quick connects
RXD
Recycle Both Times Adjustable (OFF Time First)
MRE
MI
MS
HRPDGen 09.10
Delay On Make Recycle
Delay On Make Interval
Delay On Make Single Shot
Note: If S1 is closed when input voltage is applied, the function starts and the time delay begins. (MB, MS, BRE, SRE, AMI, SL)
BRE
SRE
RXE
Delay On Break Recycle
Single Shot Recycle
Recycle Both Times Adjustable (ON Time First)
IM
AMI
SL
Legend
V Voltage R Reset S1 Initiate Switch TD1, TD2 Time Delay
Interval Delay On Make
Accumulative Delay On Make Interval
Single Shot Lockout
t Incomplete Time Delay NO Normally Open NC Normally Closed Undened time
Loading...