HRPD/HRID Power-Time
Time Delay Relay
Description
The HRPD/HRID Series combines an electromechanical relay with microcontroller timing circuitry. It is a
factory programmed module available in any 1 of 12 standard functions. Modules are manufactured without
the function assigned. When an order is received, the function software is added. It offers 12 to 240 V
operation in two universal ranges and factory xed, onboard knob or externally adjustable time delays with
a repeat accuracy of +/-0.5%. The high switching capacity of the output contacts allow for direct control
of heavy loads like compressors, pumps, motors, heaters, and lighting. HRPD has non-isolated SPDT relay
contacts, and the HRID has isolated SPDT relay contacts. An excellent choice for OEM applications where
cost is a factor. Both offer dual functions in one convenient package.
Connection
HRPD HRID
Relay contacts are
non-isolated.
S1 = Initiate Switch
UTL = Optional Untimed Load
NO = Normally Open
NC = Normally Closed
C = Common
External Resistance vs Time Delay
For details on external RT see the external resistance
vs. time delay chart at the beginning of this section.
Mechanical View
Onboard Adjust Detail
Replaces Terminals if
Ordered
Inches (Millimeters)
**Function Chart Code
Delay On Make/Delay on Break MB
Delay On Make/Recycle
(ON Time First, Equal Times) MRE
Delay On Make/Interval MI
Delay On Make/Single Shot MS
Interval/Recycle
(ON Time First, Equal Times) IRE
Delay On Break/Recycle
(ON Time First, Equal Times) BRE
Single Shot/Recycle
(ON Time First, Equal Times) SRE
Recycle
(Both Times Adjustable, ON Time First) RXE
Recycle
(Both Times Adjustable, OFF Time First) RXD
Interval/Delay On Make IM
Accumulative Delay On Make/Interval AMI
Single Shot Lockout SL
For a Complete List of Functions with Descriptions, see
Timer Function Section.
Relay contacts
are isolated.
RT is used when external
adjustment is ordered.
Dashed lines are internal
connections.
DIN rail adaptor
P/N: P1023-20
See accessory pages for
specications.
HRPD/
HRID
Series
X
Input
–W - 24...240 V AC
.........24...110 V DC
–D - 12 ... 48 V DC
Example P/N:
HRPDW2221MB Fixed – HRIDD10.5S21RXE
Available Models-
HRIDD3434RXE
HRIDD3434RXE
HRIDW2122MB
Don’t see what you need? Call us for a minimum quantity and price quote!
X X X X X
First Adjustment
(T1 or RT1)
–1 - Fixed
–2 - Onboard Adjust
–3 - External Adjust
First Time Delay*
–1 - 0.1 ... 10 s
–2 - 1 ... 100 s
–3 - 10 ... 1000 s
–4 - 0.1 ... 10 m
–5 - 1 ... 100 m
–6 - 10 ... 1000 m
–7 - 0.1 ... 10 h
–8 - 1 ... 100 h
–9 - 10 ... 1000 h
Second Adjustment
(T2 or RT 2)
–1 - Fixed
–2 - Onboard Adjust
–3 - External Adjust
Second Time Delay*
–1 - 0.1 ... 10 s
–2 - 1 ... 100 s
–3 - 10 ... 1000 s
–4 - 0.1 ... 10 m
–5 - 1 ... 100 m
–6 - 10 ... 1000 m
–7 - 0.1 ... 10 h
–8 - 1 ... 100 h
–9 - 10 ... 1000 h
*If Fixed Delay is
selected, insert
delay [0.1 ... 999]
followed by (S) secs.,
(M) mins., or (H) hrs.
Function**
–Specify Function
(Refer to Function
Chart for Code)
HRPDGen 09.10
HRPD/HRID Power-Time
Time Delay Relay
Technical Data
Time Delay
Range 100 ms ... 1000 h in 9 adjustable ranges or xed
Repeat Accuracy +/-0.5% or 20 ms, whichever is greater
Tolerance (Factory Calibration) +/-2%
Reset Time ≤ 150 ms
Initiate Time ≤ 20 ms, ≤ 1500 operations per minute
Time Delay vs. Temp. & Voltage ≤ +/-2%
Input
Voltage 12 ... 48 V DC; 24 ... 240 V AC / 24 ... 110 V DC
Tolerance 12 ... 48 V DC -15% ... +20%
24 ... 110 V DC/24 ... 240 V AC -20% ... +10%
Line Frequency 50 ... 60 Hz
Power Consumption AC ≤ 4 VA; DC ≤ 2 W
Output
Type/Form Electromechanical relay/SPDT
Ratings:
General Purpose 125/240 V AC 30 A 15 A
Resistive 125/240 V AC 30 A 15 A
28 V DC 20 A 10 A
Motor Load 125 V AC 1 hp* 1/4 hp**
240 V AC 2 hp** 1 hp**
Life Mechanical -- 1 x 10
Electrical -- 1 x 105, *3 x104, **6,000
Function Diagrams
MB
Delay On Make
Delay On Break
SPDT-N.O SPDT-N.C.
6
For a Complete List of Functions with Descriptions, see Timer Function Section.
IRE
Interval
Recycle
ProgramaCube
®
Protection
Surge IEEE C62.41-1991 Level A
Circuitry Encapsulated
Isolation Voltage
Insulation Resistance ≥100 MΩ
Polarity DC units are reverse polarity protected
Mechanical
Mounting
Package 3 x 2 x 1.5 in. (76.7 x 51.3 x 38.1 mm)
Termination
Environmental
Operating Temp. -40°C ... +60°C
Storage Temp. -40°C ... +85°C
Humidity 95% relative, non-condensing
Weight ≅ 3.9 oz (111 g)
≥1500 V RMS input to output; isolated units
Surface mt. with one #10 (M5 x 0.8) screw
0.25 in. (6.35 mm) male quick connects
RXD
Recycle
Both Times Adjustable
(OFF Time First)
MRE
MI
MS
HRPDGen 09.10
Delay On Make
Recycle
Delay On Make
Interval
Delay On Make
Single Shot
Note: If S1 is closed when input voltage
is applied, the function starts and the time
delay begins. (MB, MS, BRE, SRE, AMI, SL)
BRE
SRE
RXE
Delay On Break
Recycle
Single Shot
Recycle
Recycle
Both Times Adjustable
(ON Time First)
IM
AMI
SL
Legend
V Voltage
R Reset
S1 Initiate Switch
TD1, TD2 Time Delay
Interval
Delay On Make
Accumulative Delay On Make
Interval
Single Shot Lockout
t Incomplete Time Delay
NO Normally Open
NC Normally Closed
Undened time