SSAC HRDI Power-Time Technical Data

Page 1
Interval
HRDI Power-Time Time Delay Relay
Technical Data
Time Delay
Type Microcontroller circuitry Range 100 ms ... 100 m in 5 adjustable ranges or xed Repeat Accuracy +/-0.5 % or 20 ms, whichever is greater Tolerance (Factory Calibration) +/-1%, +/-5% Recycle Time ≤ 150 ms Time Delay vs. Temperature & Voltage +/-2%
Input
Voltage 12 or 24 V DC; 24, 120, or 230 V AC Tolerance 12 V DC & 24 V DC -15% ... +20% 24 ... 230 V AC -20% ... +10% Line Frequency 50 ... 60 Hz Power Consumption AC ≤ 4 VA; DC ≤ 2 W
Output
Type Electromechanical relay Form SPDT, non-isolated Ratings: SPDT-N.O. SPDT-N.C. General Purpose 125/240 V AC 30 A 15 A Resistive 125/240 V AC 30 A 15 A 28 V DC 20 A 10 A Motor Load 125 V AC 1 hp* 1/4 hp** 240 V AC 2 hp** 1 hp** Life Mechanical -- 1 x 106; Electrical -- 1 x 105, *3 x 104, **6,000
Protection
Surge IEEE C62.41-1991 Level A Circuitry Encapsulated Dielectric Breakdown ≥ 2000 V RMS terminals to mounting surface Insulation Resistance ≥ 100 MΩ Polarity DC units are reverse polarity protected
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw Package 3 x 2 x 1.5 in. (76.7 x 51.3 x 38.1mm) Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating / Storage Temperature -40°C ... +60°C / -40°C ... +85°C Humidity 95% relative, non-condensing Weight 3.9 oz (111 g)
External Resistance vs Time Delay
Dedicated
timers
Mechanical View
Onboard Adjust Detail Replaces Terminals if Ordered
Inches (Millimeters)
HRDIGen 09.10
5.103
SSAC, LLC. • 800-377-7722 • customerservice@ssac.com • technicalsupport@ssac.com • www.ssac.com
• denotes a preferred product
Loading...