SSAC FS100 SERIES Data Sheet

Flashers and Tower Lighting Controls
L1 N
Flashers
FS100 SERIES
Low Current Flasher
Description
Operation
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed.
Reset: Removing input voltage resets the output and the sequence to T2.
Wiring Diagram
V = Voltage L = Load R = Red Wire B = Black Wire
Features & Benefits
FEATURES BENEFITS
Compact Size: 38 x 23.9mm (1.5” x 0.94”)
Custom Flash Rates Available
Ideal for OEM applications
Tailor to specific application: custom rates range from 45 to 150 FPM
Accessories
P1023-2 “P” Clamp
Mounting Bracket Alum. 15/16
Ordering Information
MODEL INPUT VAC OUTPUT RATING A OUTPUT TYPE AC LOAD TYPE FLASH RATE
FS126 120 1 Fullwave Incandescent & Resistive 75 FPM
FS126-45 120 1 Fullwave Incandescent & Resistive 45 FPM
FS126-60 120 1 Fullwave Incandescent & Resistive 60 FPM
FS126RC 120 1 Fullwave Incandescent, Resistive, & Inductive 75 FPM
FS126RC-45 120 1 Fullwave Incandescent, Resistive, & Inductive 45 FPM
FS127 120 2 Halfwave Incandescent & Resistive 75 FPM
FS146 24 1 Fullwave Incandescent & Resistive 75 FPM
FS146RC 24 1 Fullwave Incandescent, Resistive, & Inductive 75 FPM
If you don’t find the p art you need, call us for a cus tom product 8 00-84 3-8 848
Specications
© 2016 Littelfuse Protection Relays & Controls
Rev: 1-A-062116
Flashers and Tower Lighting Controls
Flashers
FS100 SERIES
Specifications
Technical Data
Operation Flash Rate Factory fixed at 75 FPM ±20% Custom Flash Rates Available From 45-150 FPM ±20% ON/OFF Ratio 50%
Input
Voltage AC Line Frequency 50/60Hz
Output
Output Load Type Incandescent, resistive, or inductive
(Choose RC suffix for inductive loads) Maximum Load Rating Fullwave: 1A steady state Halfwave: 2A steady state
Inrush 10A
Mechanical
Mounting
(M4 x 0.7) screw
Connection/Wires 18 AWG (0.82mm2) wires 6 in. (15.2cm) Dimensions H 38.1 mm (1.5”); W 23.9 mm (0.94”)
Protection
Circuitry
Environmental
Operating/Storage Temperature Humidity 95% relative, non-condensing Weight 1.1 oz (31 g)
OFF/ON solid-state flasher (continuous duty)
24, 120VAC, ±15%
Fullwave AC or Halfwave rectified AC
Removable mounting bracket, use one #8
Encapsulated
-20° to 60°C / -40° to 85°C
Flasher Function Diagram
FLASHER (OFF FIRST)
V = Voltage R = Reset L = Load T1 = ON Time T2 = OFF Time T1 T2
© 2016 Littelfuse Protection Relays & Controls
Rev: 1-A-062116
Loading...