SSAC ERDI Econo-Timer Catalog Page

Page 1
Interval or Single ShotInterval or Single Shot
Interval or Single Shot
Interval or Single ShotInterval or Single Shot ERDI Econo-Timer Time Delay Relay
DescriptionDescription
Description
DescriptionDescription
Econo-Timers are a combination of digital electronics and an electromechanical relay. DPDT relay output for relay logic circuits, and isolation of input to output voltages. For applications such as interval on, pulse shaping, minimum run time, etc. The ERD Series are encapsulated to protect the circuitry from shock, vibration and humidity.
Knob or External Adjust or Factory Fixed Delays from 0.1 s ... 1000 m
in 11 ranges
+/-0.5% Repeat Accuracy +/- 10% Factory Calibration Encapsulated Digital Circuitry 10 A, Isolated, DPDT Output Contacts
Approvals:
AccessoriesAccessories
Accessories
AccessoriesAccessories
BB
B
BB
AA
A
AA
External adjust potentiometer P/Ns: P1004-16 P1004-16
P1004-16 (fig A)
P1004-16 P1004-16 P1004-16-X P1004-16-X
P1004-16-X (fig B)
P1004-16-X P1004-16-X
Operation - IntervalOperation - Interval
Operation - Interval
Operation - IntervalOperation - Interval
Upon application of input voltage, time delay begins, and output relay energizes. At the end of time delay, output de-energizes until input voltage is removed.
Reset:Reset:
Reset: Removing input voltage resets the time delay
Reset:Reset:
and the output.
Operation - Single ShotOperation - Single Shot
Operation - Single Shot
Operation - Single ShotOperation - Single Shot
Input voltage must be applied before & during timing. Upon momentary or maintained closure of initiate switch, output relay energizes for time delay. At the end of the delay, output de-energizes. Opening or reclosing initiate switch during timing has no affect on time delay. Output will energize if initiate switch is closed when input voltage is applied.
Reset:Reset:
Reset: Reset occurs when time delay is complete &
Reset:Reset:
initiate switch is opened. Loss of input voltage resets time delay & output.
ConnectionConnection
Connection
ConnectionConnection
Interval Single Shot
FunctionFunction
Function
FunctionFunction
Interval
Single Shot
V = Voltage L = Load S1 = Initiate Switch TD = Time Delay R = Reset
2-3 & 7-6 are Normally Open Contacts (NO) 2-4 & 7-5 are Normally Closed Contacts (NC)
Female quick connect P/N: P1015-64P1015-64
P1015-64(AWG 14/16)
P1015-64P1015-64
Quick connect to screw adaptor
P1015-18 P1015-18
P/N:
P1015-18
P1015-18 P1015-18
Versa-knob
P0700-7P0700-7
P/N:
P0700-7
P0700-7P0700-7
See accessory pages for specifications.
A knob, or terminals 9 & 10 are included on adjustable units. Relay contacts are isolated. Dashed lines are internal connections.
RT is used when external adjustment is ordered.
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
ERDI ERDI
ERDI
ERDI ERDI
SeriesSeries
Series
SeriesSeries
Example P/N:Example P/N:
Example P/N:
Example P/N:Example P/N:
ableable
able
ableable
X X
X
X X
InputInput
Input
InputInput
11
1 - 12 V DC
11 22
2 - 24 V AC
22 3 3
3 - 24 V DC
3 3 44
4 - 120 V AC
44 55
5 - 120 V DC
55 66
6 - 230 V AC
66
ERDI426 ERDI426
ERDI426 Fixed –
ERDI426 ERDI426
X X
X
X X
AdjustmentAdjustment
Adjustment
AdjustmentAdjustment
11
1 - Factory Fixed
11 2 2
2 - Knob on Unit
2 2 33
3 - External Adjust
33
ERDI410.1S ERDI410.1S
ERDI410.1S
ERDI410.1S ERDI410.1S
XX
X
XX
Time DelayTime Delay
Time Delay *
Time DelayTime Delay
1 1
1 - 0.1 ... 1 s
1 1 2 2
2 - 0.1 ... 5 s
2 2 3 3
3 - 0.1 ... 10 s
3 3 4 4
4 - 0.2 ... 15 s
4 4 5 5
5 - 0.3 ... 30 s
5 5 66
6 - 0.6 ... 60 s
66 77
7 - 0.1 ... 5 m
77 88
8 - 0.1 ... 10 m
88 99
9 - 0.2 ... 15 m
99 1010
10 - 1 ... 100 m
1010 1111
11 - 10 ... 500 m
1111
Low Voltage Products & Systems5.138
*If Fixed Delay is selected, insert delay
0.10.1
10001000
[
0.1...
1000] followed by
0.10.1
10001000
SS
(
S) sec. or (
SS
MM
M) min.
MM
ERDI2B01 01.04 .0 5
Page 2
Interval or Single ShotInterval or Single Shot
Interval or Single Shot
Interval or Single ShotInterval or Single Shot ERDI Econo-Timer Time Delay Relay
Technical Data Technical Data
Technical Data
Technical Data Technical Data
Time DelayTime Delay
Time Delay
Time DelayTime Delay
Type Digital integrated circuitry Range 100 ms ... 500 m in 11 adjustable ranges, 100 ms ... 1000 m fixed Adjustment Knob, external adjust, or fixed Repeat Accuracy +/-0.5% Tolerance (Factory Calibration) ≤ +/-10% Reset Time 150 ms Time Delay vs. Temperature & Voltage ≤ +/-2%
InputInput
Input
InputInput
Voltage 12, 24, or 120 V DC; 24, 120, or 230 V AC Tolerance 12 V DC & 24 V DC/AC -15% ... +20% 120 V DC/AC & 230 V AC -20% ... +10% Line Frequency 50 ... 60 Hz
OutputOutput
Output
OutputOutput
Type Isolated relay contacts Form Double pole double throw (DPDT) Rating 10 A resistive at 120/240 V AC & 28 V DC; 1/3 hp at 120/240 V AC Life Mechanical--1 x 107; Electrical--1 x 10
ProtectionProtection
Protection
ProtectionProtection
Isolation Voltage 1500 V RMS input to output Insulation Resistance 100 M Polarity DC units are reverse polarity protected
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with two #6 (M3.5 x 0.6) screws Package 3.5 x 2.5 x 1.7 in. (88.9 x 63.5 x 43.2 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals Operating / Storage Temperature -40°C ... +65°C / -40°C ... +85°C Weight 5.7 oz (162 g)
6
Mechanical View Mechanical View
Mechanical View
Mechanical View Mechanical View
Inches (Millimeters)
ERDI2B01 01.04 .0 5
Low Voltage Products & Systems 5.139
Loading...