SSAC ECS Series Catalog Page

Over/Under Current SensingOver/Under Current Sensing
Over/Under Current Sensing
Over/Under Current SensingOver/Under Current Sensing ECS Series Current Sensor
DescriptionDescription
Description
DescriptionDescription
The ECS Series of Single Phase AC Current Sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or under current events like locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended.
Toroidal Through Hole Wiring
0.5...50 A Trip Point Adjustable or Factory Fixed Trip Delays 10 A SPDT Isolated Output Contacts 5% Trip Point Hysteresis
(Dead Band) Approvals:
OperationOperation
Operation
OperationOperation
Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay , the output r elay is energized. When the current returns to the normal run condition, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero.
AdjustmentAdjustment
Adjustment
AdjustmentAdjustment
Select the desired function, over or under current sensing. Set the trip point and trip delay to approximate settings. Apply power to the ECS and the monitored load. Turn adjustment and watch the LED. LED will light; turn slightly in opposite direction until LED is off. Adjustment can be done while connected to the control circuitry if the trip delay is set at maximum.
ConnectionConnection
Connection
ConnectionConnection
FunctionFunction
Function
FunctionFunction
Overcurrent
Undercurrent
TP = T rip Point R = Reset OC = Monitored Curr ent NO = Normally Open Contact NC = Normally Closed Contact A = Sensing Delay On Start Up TD = Trip Delay
AccessoriesAccessories
Accessories
AccessoriesAccessories
Female quick connect P/Ns: P1015-13 P1015-13
P1015-13
(AWG 10/12)
P1015-13 P1015-13 P1015-64P1015-64
P1015-64
(AWG 14/16)
P1015-64P1015-64 P1015-14 P1015-14
P1015-14
(AWG 18/22)
P1015-14 P1015-14
See accessory pages for specifications.
Relay contacts are isolated. Dashed lines are internal connections.
V = Voltage I> = Overcurrent I< = Undercurrent W = Insulated Wire Carrying Monitored Current
OrOr
dering Tdering T
Or
dering T
OrOr
dering Tdering T
XX
X
XX
SeriesSeries
Series
SeriesSeries
ECSECS
ECS -(selectable over or
ECSECS
under current sensing)
ECSH ECSH
ECSH -(overcurrent sensing)
ECSH ECSH ECSLECSL
ECSL - (undercurrent sensing)
ECSLECSL
Example P/N:Example P/N:
Example P/N:
Example P/N:Example P/N:
ableable
able
ableable
ECS41AC ECS41AC
ECS41AC Fixed –
ECS41AC ECS41AC
XX
X
XX
InputInput
Input
InputInput
11
1 - 12 V DC
11 22
2 - 24 V AC
22 33
3 - 24 V DC
33 44
4 - 120 V AC
44 66
6 - 230 V AC
66
ECSH610AD ECSH610AD
ECSH610AD
ECSH610AD ECSH610AD
XX
X
XX
T T
T
T T
Fixed ­Specify in 1 A increments
Adjustable RangesAdjustable Ranges
Adjustable Ranges
Adjustable RangesAdjustable Ranges
00
0 - 0.5 ... 5 A
00 11
1 - 2 ... 20 A
11 H H
H - 5 ... 50 A
H H
rip Pointrip Point
rip Point
rip Pointrip Point
2 2
2 ...
2 2
50 50
50 A
50 50
XX
X
XX
TT
rip Delayrip Delay
T
rip Delay
TT
rip Delayrip Delay
F F
F - Factory Fixed:
F F
Specify
Adjustable RangesAdjustable Ranges
Adjustable Ranges
Adjustable RangesAdjustable Ranges
AA
A - 0.150 ... 7 s
AA BB
B - 0.5 ... 50 s
BB
Low Voltage Products & Systems8.4
.08 .08
.08 ...
.08 .08
5050
50 s
5050
XX
X
XX
Sensing DelaySensing Delay
Sensing Delay
Sensing DelaySensing Delay on Start up on Start up
on Start up
on Start up on Start up
BlankBlank
Blank - 0 s
BlankBlank
CC
C - 1 s
CC
DD
D - 2 s
DD EE
E - 3 s
EE FF
F - 4 s
FF
GG
G - 5 s
GG HH
H - 6 s
HH
ECS02B01 12.28.04
Over/Under Current SensingOver/Under Current Sensing
Over/Under Current Sensing
Over/Under Current SensingOver/Under Current Sensing ECS Series Current Sensor
Technical Data Technical Data
Technical Data
Technical Data Technical Data
SensorSensor
Sensor
SensorSensor
Type Toroidal, through hole wiring Mo de Over or under current, switch selectable on the unit or factory fixed Trip Point Range 0.5 ... 50 A in 3 adjustable ranges or fixed Tolerance: Adjustable Guaranteed range Fixed 0.5 ... 25 A: 0.5 A or +/-5% whichever is less; 26 ... 50 A: +/-2.5% Maximum Allowable Current Trip Point Hysteresis ≅ +/-5% Trip Point vs. Temperature +/- 5% Response Time 75 ms Frequency 45 ... 500 Hz Type of Detection Peak detection
TT
rip Delayrip Delay
T
rip Delay
TT
rip Delayrip Delay
Type Analog Range: Adjustable 0.150 ... 7 s; 0.5 ... 50 s (Guaranteed ranges) Factory Fixed 0.08 ... 50 s (+/-10%) Delay vs. Temperature +/-15% Sensing Delay on Startup Factory fixed 0 ... 6 s: +40% ... 0%
InputInput
Input
InputInput
Voltage 24 , 120, or 230 V AC; 12 or 24 V DC Tolerance 12 V DC & 24 V DC/AC -15% ... +20% 120 & 230 V AC -20% ... +10% Line Frequency 50 ... 60 Hz
OutputOutput
Output
OutputOutput
Type Electromechanical relay Form Isolated single pole double throw (SPDT) Rating 10 A resistive at 240 V AC; 1/4 hp at 125 V AC; 1/2 hp at 250 V AC Life Mechanical – 1 x 106 ; Electrical – 1 x 10
ProtectionProtection
Protection
ProtectionProtection
Circuitry Encapsulated Isolation Voltage 2500 V RMS input to output Insulation Resistance 100
MechanicalMechanical
Mechanical
MechanicalMechanical
Mounting Surface mount with two #6 (M3.5 x 0.6) screws Termination Humidity 95% relative, non-condensing Operating/Storage Temperature -40°C ... +60°C / -40°C ... +85°C Weight 6.4 oz (181 g)
Steady – 50 A turns; Inrush – 300 A turns for 10 s
5
M
0.25 in. (6.35 mm) male quick connect terminals (5)
Mechanical View Mechanical View
Mechanical View
Mechanical View Mechanical View
Multiple TMultiple T
Multiple T
Multiple TMultiple T T o incr ease sensitivity , multiple turns may be made through the ECS's toroidal sensor. The trip point range is divided by the number of turns through the toroidal sensor to create a new range.
Using an ExterUsing an Exter
Using an Exter
Using an ExterUsing an Exter Select a 2 VA, 0 to 5 A output CT, rated for the current to be monitored. Select
ECS02B01 12.28.04
ECS adjustment range 0. Pass the CT's secondary wire lead through the ECS's toroid and connect both ends together.
Low Voltage Products & Systems 8.5
urur
ur
urur
ns Tns T
ns T
ns Tns T
o Incro Incr
o Incr
o Incro Incr
nal Currnal Curr
nal Curr
nal Currnal Curr
ease Sensitivityease Sensitivity
ease Sensitivity
ease Sensitivityease Sensitivity
ent Tent T
ransformer (CT)ransformer (CT)
ent T
ransformer (CT)
ent Tent T
ransformer (CT)ransformer (CT)
Inches (Millimeters)