![](/html/9e/9efd/9efdb3e21af62be5f7be26c7245c77e25408829b13de47e28c82a5abbefeb86a/bg1.png)
Wireless Controller for
Low Voltage Hoist
Instruction Manual
Models:
GMC12-WLV-3H24, -12H6
GMC8-WLV-2H24
version 1.0 since 6 November 2018
ATTENTION!
This instruction manual contains important information about the installation and the use of
the equipment. Please read and follow these instructions carefully.
Always ensure that the power to the equipment is disconnected before opening the
equipment or commencing any maintenance work.
GMC12-WLV-3H24_en_manual_M237
(1 /16)
![](/html/9e/9efd/9efdb3e21af62be5f7be26c7245c77e25408829b13de47e28c82a5abbefeb86a/bg2.png)
Safety information
IMPORTANT INSTRUCTIONS
All safety and operating instructions should be read before the equipment is installed or operated.
IMPORTANT SAFETY INFORMATION
The following general safety precautions have to be observed during all phases of operation, service,
and the repair of this equipment. Failure to comply with these precautions or with specific warnings
in this manual violates safety standards of design, manufacture, and the intended use of this
equipment.
Do not operate in an explosive atmosphere!
Do not operate this equipment in the presence of flammable gases or fumes. Operation of any
electrical instrument in such an environment constitutes a definite safety hazard.
Water, moisture, heat and humidity
Do not operate this equipment near water or in areas with wet floors or in high humidity atmosphere,
where condensation forms on the equipment. It should never be placed near or over a heat register
or other source of heated air and it should not be installed or operated without proper ventilation.
(2 /16)
![](/html/9e/9efd/9efdb3e21af62be5f7be26c7245c77e25408829b13de47e28c82a5abbefeb86a/bg3.png)
Functions and Control
Motor Controller has been designed to control from 1 to 12 electrically compatible motors, either
separately or simultaneously – controlled via switches located on front panel or wireless
remote/pendant. Optionally you can link GO/STOP button by link connector.
Each device is equipped with unique APA /Automatic Phase Align/ module that guarantees that on
any alignment of input phases the motors will move in the correct direction. If any line wire is
disconnected, the hoist controller stops to ensure safe operation. Unit is also equipped with AVM
/Automatic Voltage Metering/ module. This module checks the main voltage for AC400V +-20% and
the star configuration. if there is any problem with the main voltage, you’re notified, and unit will not
run any hoist.
Unit will not work when:
One phase is missing
Under-voltage is present on lines
Over-voltage is present on lines
All electrical components carry their own individual cSA/UL, CE and comply with European Directives.
The components are housed in robust steel 19" rack casing with powder coating. Complete unit
complies with the CE according the Certification of conformity attached to this manual.
Operation
The motors/hoists connected with the GMCseries controller can be activated individually or
simultaneously using the GO switch located on the front panel or wireless remote. Units can be
optionally linked together to create bigger systems.
How to start
Connect the CEE32/5p plug to the AC400V +-20% power supply – turn the key to ON
position. When the main power is OK, the power LED will light green, otherwise the unit is
OFF. Check phase voltages, frequency and contact the manufacturer if help is needed.
Connect the plugs for the electric hoists to the output sockets.
Check that the emergency STOP mushroom on the device is not engaged or any other linked
device in system.
Move lever on the front panel or WMC remote corresponding to each motor to the required
position:
o UP - Lever in upper position
o STAY – Lever in middle position
o DOWN - Lever in lower position
Pushing the GO button will activate the motors to move simultaneously
Releasing the GO button will stop the movement of the motors simultaneously.
When the device is not being used, it is highly recommended to turn it OFF by the key
located on the front panel.
(3 /16)
![](/html/9e/9efd/9efdb3e21af62be5f7be26c7245c77e25408829b13de47e28c82a5abbefeb86a/bg4.png)
To Move a single/several hoist(s):
Set the UP/DOWN toggle switch for certain motor to the desired direction. The associated
LED should light green for UP, or red for DOWN direction
Hold the GO button until the motor is moved the desired height, then release.
WMCseries remote controller
WMCseries remote allows control of the device via wireless connection.
(4 /16)
![](/html/9e/9efd/9efdb3e21af62be5f7be26c7245c77e25408829b13de47e28c82a5abbefeb86a/bg5.png)
STOP:
This latching pushbutton switch turns the Hoist Control system off. Once the STOP button has been
pressed, it locks the unit to OFF position and must be rotated clockwise and released before
disengaging.
GO:
This pushbutton switch turns the selected channels of Hoist Control system ON, when the unit is
active. Once the GO button has been pressed, the energizing of the hoists is ON. The backlight of GO
button in local mode on the Base unit is ON only when one or more direction switches are in active
position /UP or DOWN/.
DIRECTION SWITCHES:
They allow changing of the direction of movement for each motor/hoist separately:
BATTERY STATUS LED:
Battery status LED indicator:
Green: 100-90%
Orange: 90-10%
Red: 10%
Red + beep: 5%
REMOTE STATUS LED:
Status LED indicator of WMC remote unit:
Green: Power ON
Green blinking: Power ON – SLEEP - move the direction switch or press GO button to resume
from sleep. This status becomes after 3 minutes of inactivity.
Orange: Indicates direction switch activity
Red: GO button is pressed – sending commands to the Base unit
(5 /16)