SRS Labs GMC12-LV-H6, GMC8-LV-H6 Instruction Manual

Hoist controller for LV
hoist
Instruction Manual
Models:
GMC12-LV-H6, GMC8-LV-H6
ATTENTION!
This instruction manual contains important information about the installation and the use of
the equipment. Please read and follow these instructions carefully.
Always ensure that the power to the equipment is disconnected before opening the
equipment or commencing any maintenance work.
GMCXX-LV-H6_en_manual_M236
( 1 / 12)
1. Safety information
IMPORTANT INSTRUCTIONS!
All safety and operating instructions should be read before the equipment is installed or operated.
IMPORTANT SAFETY INFORMATIONS
The following general safety precautions have to be observed during all phases of operation, service, and repair of this equipment. Failure to comply with these precautions or with specific warning in this manual violates safety standards of design, manufacture, and intended use of this equipment.
Do not operate in an explosive atmosphere
Do not operate this equipment in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
Water, moisture, heat and humidity
Do not operate this equipment near water or in areas with wet floors, also not in high humidity atmosphere where condensation forms on the equipment. It should never be placed near or over heat register or other source of heated air and it should not be installed or operated without proper ventilation.
( 2 / 12)
2. Functions and Control
Motor Controller has been designed to control from 1 to 12 electrically compatible motors, either separately or simultaneously – controlled via switches located on front panel or a cable remote/pendant. Optionally you can link GO/STOP button by link connector.
Each device is equipped with unique APA module / Automatic Phase Align / which guarantees that on any align of input phases the motors are still moving in the same direction. If any line wire will be disconnected the hoist controller stops and ensure safe operation. Unit is also equipped wit AVM module / Automatic voltage metering /. This module checks main voltage for AC400V +-20%, star configuration and if there is any problem with main voltage you’re notified and unit will not run any hoist
Unit will not work when:
One phase is missing
Under voltage on lines
Overvoltage on lines
All electrical components carry their own individual cSA/UL, CE and comply with European Directives. The components are housed in robust steel 19" rack casing with powder coating. Complete unit complies with the CE according the Certification of conformity attached to this manual.
3. Operation
The Motor/hoists connected with the GMCseries controller, can be activated individually or simultaneously using the GO switch located on the front panel or wireless remote. Units can be optionally linked together to create bigger systems.
3.1 How to start
Connect the CEE32/5p plug to the AC400V +-20% power supply – turn the key to ON position. When the main is OK there will be power LED lit in green, otherwise the unit is off. Check phase voltages, frequency and contact manufacturer in case of help.
Connect the plugs for the electric hoists to the Harting 6 sockets.
Check that the emergency STOP mushroom is not engaged on device or any other linked
device in system.
Move lever on front panel or WMC remote corresponding to each motor, to the position required:
o UP - Lever in upper position o STAY – Lever in middle position o DOWN - Lever in lower position
Pushing the GO button will activate the motors to move simultaneously
Releasing the GO button will stop the movement of the motors simultaneously.
When is device not used is highly recommended to turn it OFF by key located on front panel.
( 3 / 12)
3.2 To Move a Single/Several hoist:
Set the UP/DOWN toggle switch for that motor to the desired direction. The associated LED should light Green for UP, or Red for DOWN direction
Hold the GO button until the motor are moved the desired height, then release.
3.3 Link of Base units:
Two or up to 30 units can be linked via link connector located on front panel. For link you’ll need 5pin DMX data cable.
Due safety requirements link works only in LOCAL / LINK MODE of controller
( 4 / 12)