SRP SR1500TL, SR2000TL, SR3000TL, SR4200TL, SR5000TL User Manual

USER MANUAL
SUNNY ROO SERIES PHOTOVOLTAIC INVERTER
SR1500TL / SR2000TL / SR3000TL / SR4200TL / SR5000TL
32
www.sunnyrooproducts.com
Introduction...............................................................................................................................2
Important Safety Instructions................................................................................................4
Product Overview....................................................................................................................5
Installation................................................................................................................................10
Front Panel Functional Descriptions................................................................................16
Starting the SR Series Inverter............................................................................................17
The Communications Interface.........................................................................................23
Inverter Status Diagnostics and Repair...........................................................................26
Specifications...........................................................................................................................30
Introduction
Thank you for buying this Sunny Roo Series Inverter. Many years of design experience has gone into the construction of this device, and your Sunny Roo Series Inverter should give your solar power system many years of trouble-free operation.
Your new Inverter is a complex electronic system, and over its life-time it will be confronted with a variety of local conditions. If a malfunction of your Sunny Roo Series Inverter occurs, please contact your specialised dealer directly. Your dealer will assist you or will refer you to someone who can help with your query.
Please read this User Manual carefully to familiarise yourself with your new device. Please pay particular attention to information regarding the installation and commissioning of your Sunny Roo Series Inverter.
Important Safety Instructions
General
This manual contains important instructions for the Sunny Roo Series SR 1500TL, 2000TL, 3000TL, 4200TL, 5000TL that should be followed during installation and maintenance of the inverters.
Housing
Only qualified installers are authorised to open the connection area. Do not open the connection area when the inverter is under load (ie. ensure power is not running through inverter).
Only trained service staff may open the upper portion (power stage) of the SR Series Inverter, and only when the inverter is not under load.
Repair
Only trained service staff are authorised to carry out repairs to the SR Series Inverter unit.
Warning! Incorrect operation and/or work performed can cause serious injury and damage! Only qualified personnel are authorised to install your SR Series Inverter; installation should be carried out within the scope of the respective technical regulations. Do not start operation or carry out maintenance work before reading the chapter ‘Important Safety Instructions’.
Warning! These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that specified in the operating instructions unless qualified to do so.
!
!
54
www.sunnyrooproducts.com
PV Module
Before connecting the solar modules, you must check whether the voltage parameters specified in the manufacturer’s data correspond with the actual parameters. When checking the voltage reading, please take into account that solar modules supply a higher no-load voltage when temperature is low and sunlight level remains unchanged. At 14°F (-10°C) the open-circuit voltage of the PV modules must never exceed 500V. The data sheet of the solar module will tell you the temperature factors applicable for determining the theoretical open-circuit voltage at 14°F (-10°C). If the solar modules exceed an open-circuit voltage of 500V, the SR Series Inverter may be damaged. In these circumstanc­es all warranty rights will be void.
The SR Series Inverter includes a Residual Current Monitoring Unit (RCMU) according to VDE0126-1-1. This device measures the Earth current of the PV array and will prevent the inverter from feeding the grid in the case of an Earth fault.
Grid Connection
Only appropriately licensed contractors are authorised to connect the SR Series Inverter to the grid. Consult your local authorities for specific require­ments. Before connecting the SR Series Inverter to the grid, permission for the connection must be granted by the utility company.
Product Overview
External Dimensions
Module number
Dimensions (mm)
SR1500TL, SR2000TL,
SR3000TL
SR4200TL,
SR5000TL
L 455 455 H 430 510 D 170 170
76
www.sunnyrooproducts.com
Unit Description
1. LCD & LED Display: Shows the operation information and status of the
inverter.
2. Solar Array Input: Plug-and-play connector terminals for the connection of the solar modules (The SR1500TL/2000TL/SR3000TL only have one PV string input).
3. Standard Communication Port : EPO & RS232.
4. Optional Communication Slot: USB, RS485, Dry Contact, TCP/ IP.
5. AC Output Terminal: AC output for the utility supply.
Installation
Please read ‘Important Safety Instructions’ (page 3 & 4) before installing the SR Series Inverter.
Unpacking
Inspect the SR Series Inverter upon receipt. If damage has occurred during shipment please notify your specialised dealer immediately. The inverter pack­aging is recyclable, we encourage you to re-use it or dispose of it properly.
Remove the SR Inverter from its box. Check the package contents. Standard contents should include: 1 set of accessories 1 data CD-ROM 1 Mounting Frame Accessory Kit (shown below):
SR4200TL/5000TL SR1500TL/2000TL/3000TL
98
www.sunnyrooproducts.com
Installation Requirements
The SR Series Inverter is heavy. Take this weight into consideration when choosing the installation site and method of installation.
To ensure proper operation and long operating life, always position the SR Series Inverter according to the following requirements:
(1) The SR Series Inverter is designed for
outdoor installation, and should be installed away from direct sunlight. Increased ambient temperatures and/or installation in poorly ventilated and warm indoor locations may reduce the yield of the PV system. The optimum ambient temperature lies within the -25°C to +50°C range.
(2) The SR Series Inverter is designed to be mounted on a vertical wall. If installing the unit outdoors, make sure that it is not slanting forward. We advise against installing the unit in a horizontal position.
(3) When choosing the installation site, ensure there is enough space for heat dissipation. Under normal conditions, installers should adhere to the following guidelines regarding space to be left clear around the inverter:
Mounting the Unit
We recommend that you use the supplied wall mounting bracket to mount the SR Series Inverter. For vertical installation and installation on solid concrete or block walls, be sure to take into account the weight of the inverter when selecting the mounting materials.
If you do not want to use the supplied wall mounting bracket, refer to the dimensions shown in the drawing above. The procedure for mounting the inverter using the wall mounting bracket is described on the following pages.
SR1500TL/2000TL/3000TL 23Kg
SR4200TL/5000TL 28Kg
1110
www.sunnyrooproducts.com
Installation: Step by Step
Step 1. Fit the wall mounting bracket.
When marking the positions of the drill holes, use the wall mounting bracket as a drilling template.
Step 2. Hang the SR Series Inverter onto the wall mounting bracket using its upper mounting plate. This ensures the inverter cannot be moved sideways.
Step 3. Check that the SR Series Inverter is positioned securely on the bracket.
Electrical Installation
The correct installation for the SR Series Inverter is shown in the following diagram below (Fig. 1)
Fig. 1
Loading...
+ 11 hidden pages